Deformation of varifocal mirror with narrow frame by SOI wafer residual stress

Authors:

Abstract
Silicon‐on‐insulator (SOI) wafers are used for many micro‐electro‐mechanical systems (MEMS). The influences of residual stress of SOI wafer on the fabricated structures are important especially for micro‐mirror because the optical performances are often affected by them. In this study, we propose an analytical calculation for the deformation of mirror and frame of a varifocal mirror. The deformations of the fabricated structures were measured using a white light interferometer. The frame was tilted at 2.8 mrad which was explained by the calculated value of 3.9 mrad. The mirror was deflected by 100 nm with the top‐flat shape, which also agreed well with the proposed analysis. © 2012 Wiley Periodicals, Inc. Electron Comm Jpn, 95(8): 26‐33, 2012; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI 10.1002/ecj.11381