The use of multi-site photoplethysmography (PPG) as a screening tool for coronary arterial disease and atherosclerosis
- 1 June 2021
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (6) , 064006
Abstract
Objective . We present the design and validation of a non-invasive smart-phone based screening tool for atherosclerosis and coronary arterial disease (CAD), which is the leading cause of mortality worldwide. Approach . We designed a three-channel photoplethysmography (PPG) device that connects to a smart phone application for measuring pulse transit time (PTT) and pulse wave velocity (PWV) using PPG probes that are simultaneously clipped onto to the ear, index finger, and big toe, respectively. Validation was performed through a clinical study with 100 participants (age 20 to 77) at a research hospital in Nagpur, India. Study subjects were stratified by age and divided into three groups corresponding to the disease severity: CAD, hypertensive (‘Pre-CAD’), and Healthy. Main results . PWV measurements derived from the Ear-Toe probe measurements yielded the best performance, with median PWV values increasing monotonically as a function of disease severity and age, as follows: 14.2 m s −1 for the older-patient CAD group, 12.2 m s −1 for the younger-patient CAD group, 11.6 m s −1 for the older-patient Pre-CAD group, 10.2 m s −1 for the younger-patient Pre-CAD group, 9.7 m s −1 for the older healthy controls, and 8.4 m s −1 for the younger healthy controls. Using just two simple features, the PTT and patient height, we demonstrate a machine learning prediction model for CAD with a median accuracy of 0.83 (AUC). Significance . This work demonstrates the ability to predict atherosclerosis and CAD using a single simple physiological measurement with a multi-site PPG tool that is electrically powered by a mobile phone and does not require any electrocardiogram reference. Furthermore, this method only requires a single anthropometric measurement, which is the patient’s height.Keywords
Funding Information
- Sir Ratan Tata Trust and Navajbai Ratan Tata Trust
This publication has 15 references indexed in Scilit:
- The use of photoplethysmography for assessing hypertensionnpj Digital Medicine, 2019
- Diagnostic Performance of a Smartphone‐Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care SettingJournal of the American Heart Association, 2016
- Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and PracticeIEEE Transactions on Biomedical Engineering, 2015
- Cuffless Differential Blood Pressure Estimation Using Smart PhonesIEEE Transactions on Biomedical Engineering, 2012
- Receiver Operating Characteristic Curve in Diagnostic Test AssessmentJournal of Thoracic Oncology, 2010
- Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: ‘establishing normal and reference values’European Heart Journal, 2010
- The difference in pulse transit time to the toe and finger measured by photoplethysmographyPhysiological Measurement, 2001
- Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toesIEE Proceedings - Science, Measurement and Technology, 2000
- Determination of pulse wave velocities with computerized algorithmsAmerican Heart Journal, 1991
- Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community.Circulation, 1983