Tracked 3D ultrasound and deep neural network-based thyroid segmentation reduce interobserver variability in thyroid volumetry
Open Access
- 29 July 2022
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (7) , e0268550
Abstract
Thyroid volumetry is crucial in the diagnosis, treatment, and monitoring of thyroid diseases. However, conventional thyroid volumetry with 2D ultrasound is highly operator-dependent. This study compares 2D and tracked 3D ultrasound with an automatic thyroid segmentation based on a deep neural network regarding inter- and intraobserver variability, time, and accuracy. Volume reference was MRI. 28 healthy volunteers (24—50 a) were scanned with 2D and 3D ultrasound (and by MRI) by three physicians (MD 1, 2, 3) with different experience levels (6, 4, and 1 a). In the 2D scans, the thyroid lobe volumes were calculated with the ellipsoid formula. A convolutional deep neural network (CNN) automatically segmented the 3D thyroid lobes. 26, 6, and 6 random lobe scans were used for training, validation, and testing, respectively. On MRI (T1 VIBE sequence) the thyroid was manually segmented by an experienced MD. MRI thyroid volumes ranged from 2.8 to 16.7ml (mean 7.4, SD 3.05). The CNN was trained to obtain an average Dice score of 0.94. The interobserver variability comparing two MDs showed mean differences for 2D and 3D respectively of 0.58 to 0.52ml (MD1 vs. 2), −1.33 to −0.17ml (MD1 vs. 3) and −1.89 to −0.70ml (MD2 vs. 3). Paired samples t-tests showed significant differences for 2D (p = .140, p = .002 and p = .002) and none for 3D (p = .176, p = .722 and p = .057). Intraobsever variability was similar for 2D and 3D ultrasound. Comparison of ultrasound volumes and MRI volumes showed a significant difference for the 2D volumetry of all MDs (p = .002, p = .009, p <.001), and no significant difference for 3D ultrasound (p = .292, p = .686, p = 0.091). Acquisition time was significantly shorter for 3D ultrasound. Tracked 3D ultrasound combined with a CNN segmentation significantly reduces interobserver variability in thyroid volumetry and increases the accuracy of the measurements with shorter acquisition times.Keywords
All Related Versions
Funding Information
- H2020 LEIT Information and Communication Technologies
This publication has 28 references indexed in Scilit:
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid NodulesKorean Journal of Radiology, 2015
- Multimodal Evaluation of 2-D and 3-D Ultrasound, Computed Tomography and Magnetic Resonance Imaging in Measurements of the Thyroid Volume Using Universally Applicable Cross-Sectional Imaging Software: A Phantom StudyUltrasound in Medicine & Biology, 2014
- 3D ultrasonography is as accurate as low-dose CT in thyroid volumetryNuklearmedizin-Nuclear Medicine, 2014
- A Novel Thyroid Phantom for Ultrasound Volumetry: Determination of Intraobserver and Interobserver VariabilityThyroid®, 2006
- Accuracy of Three-Dimensional Ultrasound for Thyroid Volume Measurement in Children and AdolescentsThyroid®, 2004
- Thyroid Volume Measurement in Patients Prior to Radioiodine Therapy: Comparison Between Three-Dimensional Magnetic Resonance Imaging and UltrasonographyThyroid®, 2002
- The Use of Three-Dimensional Ultrasound for Thyroid VolumetryThyroid®, 2001
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Volumetrie der Schilddrüsenlappen mittels Real-time-Sonographie* 1DMW - Deutsche Medizinische Wochenschrift, 1981