Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO)
Open Access
- 9 August 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (8) , e0201808
Abstract
To develop a novel approach for highly accelerated Magnetic Resonance Fingerprinting (MRF) acquisition. The proposed method combines parallel imaging, soft-gating and key-hole approaches to highly accelerate MRF acquisition. Slowly varying flip angles (FA), commonly used during MRF acquisition, lead to a smooth change in the signal contrast of consecutive time-point images. This assumption enables sharing of high frequency data between different time-points, similar to what is done in some dynamic MR imaging methods such as key-hole. The proposed approach exploits this information using a SOft-weighted key-HOle (MRF-SOHO) reconstruction to achieve high acceleration factors and/or increased resolution without compromising image quality or increasing scan time. MRF-SOHO was validated on a standard T1/T2 phantom and in in-vivo brain acquisitions reconstructing T1, T2 and proton density parametric maps. Accelerated MRF-SOHO using less data per time-point and less time-point images enabled a considerable reduction in scan time (up to 4.6x), while obtaining similar T1 and T2 accuracy and precision when compared to zero-filled MRF reconstruction. For the same number of spokes and time-points, the proposed method yielded an enhanced performance in quantifying parameters than the zero-filled MRF reconstruction, which was verified with 2, 1 and 0.7 (sub-millimetre) resolutions. The proposed MRF-SOHO enabled a 4.6x scan time reduction for an in-plane spatial resolution of 2x2 mm2 when compared to zero-filled MRF and enabled sub-millimetric (0.7x0.7 mm2) resolution MRF.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EPSRC EP/P001009/)
- FONDECYT (1161055)
- Wellcome Trust (WT 088641/Z/09/Z)
- NIHR
This publication has 39 references indexed in Scilit:
- Improved least squares MR image reconstruction using estimates of k‐Space data consistencyMagnetic Resonance in Medicine, 2011
- Quantitative Relaxometry of the BrainTopics in Magnetic Resonance Imaging, 2010
- TI-relaxation time changes over five years in relapsing-remitting multiple sclerosisMultiple Sclerosis Journal, 2010
- Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonanceBlood, 2005
- High‐resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2Magnetic Resonance in Medicine, 2004
- Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)‐algorithm: Principles and applications to hyperecho and TRAPS sequencesMagnetic Resonance in Medicine, 2003
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Resampling of data between arbitrary grids using convolution interpolationIEEE Transactions on Medical Imaging, 1999
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- Practical T2 quantitation for clinical applicationsJournal of Magnetic Resonance Imaging, 1992