The new surgical robot Hugo™ RAS for total hysterectomy: a pilot study
Authors:
- G MonterossiGMG Monterossi
- L Pedone AnchoraLAL Pedone Anchora
- R OlivaROR Oliva
- A FagottiAFA Fagotti
- F FanfaniFFF Fanfani
- B CostantiniBCB Costantini
- A NaldiniANA Naldini
- D GiannarelliDGD Giannarelli
- G ScambiaGSG Scambia
Open Access
- 1 December 2023
- journal article
- research article
- Published by Galenos Yayinevi in Human Reproduction Open
- Vol. 15 (4) , 331-337
Abstract
Background: With the rising popularity of robotic surgery, Hugo™ RAS is one of the newest surgical robotic platforms. Investigating the reliability of this tool is the first step toward validating its use in clinical practice; and presently there arelimited data available regarding this. The literature is constantly enriched with initial experiences, however no study has demonstrated the safety of this platform yet. Objectives: This study aimed to investigate its reliability during total hysterectomy. Materials and Methods: A series of 20 consecutive patients scheduled for minimally invasive total hysterectomy with or without salpingo-oophorectomy for benign disease or prophylactic surgery were selected to undergo surgery with Hugo™ RAS. Data regarding any malfunction or breakdown of the robotic system as well as intra- and post-operative complications were prospectively recorded. Results: Fifteen of the twenty patients (75.0%) underwent surgery for benign uterine diseases, and five (25.0%) underwent prophylactic surgery. Among the entire series, an instrument fault occurred in one case (5.0%). The problem was solved in 4.8 minutes and without complications for the patient. The median total operative time was 127 min (range, 98–255 min). The median estimated blood loss was 50 mL (range:30–125 mL). No intraoperative complications were observed. One patient (5.0%) developed Clavien-Dindo grade 2 post-operative complication. Conclusions: In this pilot study, Hugo™ RAS showed high reliability, similar to other robotic devices. What is new? Present findings suggest that Hugo™ RAS is a viable option for major surgical procedures and deserves further investigation in clinical practice.Keywords
This publication has 30 references indexed in Scilit:
- The new robotic TELELAP ALF-X in gynecological surgery: single-center experienceSurgical Endoscopy, 2015
- Updated Hysterectomy Surveillance and Factors Associated With Minimally Invasive HysterectomyJSLS : Journal of the Society of Laparoscopic & Robotic Surgeons, 2014
- Reliability of robotic system during general surgical procedures in a university hospitalThe American Journal of Surgery, 2013
- Robotically Assisted vs Laparoscopic Hysterectomy Among Women With Benign Gynecologic DiseaseJAMA, 2013
- Malfunction and failure of robotic systems during general surgical proceduresSurgical Endoscopy, 2012
- Malfunction of the da Vinci robotic system in urologyInternational Journal of Urology, 2012
- Failure and Malfunction of da Vinci Surgical Systems During Various Robotic Surgeries: Experience From Six Departments at a Single InstituteUrology, 2009
- The Clavien-Dindo Classification of Surgical ComplicationsAnnals of Surgery, 2009
- Pilot study assessing robotic laparoscopic hysterectomy and patient outcomesJournal of Minimally Invasive Gynecology, 2006
- Clinical applications of visual analogue scales: a critical reviewPsychological Medicine, 1988