Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter
Authors:
- 25 October 2016
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (12) , 1429-1436
Abstract
This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.Keywords
Funding Information
- The Charles and Sylvia Viertel Clinical Investigatorship fund.
This publication has 19 references indexed in Scilit:
- Unipolar Electrogram Morphology to Assess Lesion Formation During Catheter Ablation of Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2013
- Characterization of the impact of catheter-tissue contact force in lesion formation during cavo-tricuspid isthmus ablation in an experimental swine modelEP Europace, 2013
- Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial TreatmentCirculation: Arrhythmia and Electrophysiology, 2013
- The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA studyHeart Rhythm, 2012
- Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmiasHeart Rhythm, 2012
- Voltage‐Guided Ablation Technique for Cavotricuspid Isthmus‐Dependent Atrial Flutter: Refining the Continuous LineJournal of Cardiovascular Electrophysiology, 2012
- Effect of Catheter Ablation on Progression of Paroxysmal Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2011
- Long-Term Outcomes After Catheter Ablation of Cavo-Tricuspid Isthmus Dependent Atrial FlutterCirculation: Arrhythmia and Electrophysiology, 2009
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- Results From the Loire-Ardèche-Drôme-Isère-Puy-de-Dôme (LADIP) Trial on Atrial Flutter, a Multicentric Prospective Randomized Study Comparing Amiodarone and Radiofrequency Ablation After the First Episode of Symptomatic Atrial FlutterCirculation, 2006