Paul A. Gould
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul A. Gould has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Andrew Claughton
Department of Cardiology Princess Alexandra Hospital Brisbane Queensland Australia
3 shared publicationsGerald C. Kaye
Department of Cardiology Princess Alexandra Hospital Brisbane Queensland Australia
2 shared publicationsKevin Ng
Department of Cardiology, Princess Alexandra Hospital, Queensland, Australia
2 shared publicationsKieran Dauber
Department of Cardiology Princess Alexandra Hospital Brisbane Queensland Australia
2 shared publicationsWaheed Ahmad
Department of Cardiology, Princess Alexandra Hospital, Woolangabba, Queensland, Australia
2 shared publications- Andre Conradie
Friendly Society Private Hospital, Bundaberg, QLD 4670, Australia
1 shared publication
Latest Publications
- Open Access
- 17 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (47) , 110628
First-in-Human Permanent Totally Leadless Left Ventricular Septal Endocardial Pacing With Atrioventricular Synchrony
- 17 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (47) , 110628
Open AccessFirst-in-Human Permanent Totally Leadless Left Ventricular Septal Endocardial Pacing With Atrioventricular Synchrony
- Open Access
- 17 September 2026
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (6) , 1481-1491
First-in-human experience from RESET-AF (Rapid onE-Shot Electroporation Trial for Atrial Fibrillation)
Background and Aims: Pulsed field ablation (PFA) is increasingly used to treat patients with atrial fibrillation (AF). The RESET-AF was a single-arm, first-in-human, clinical trial of AF ablation using a novel, single-shot PFA system (ElePulse ® , CRC EP, Tustin, CA, USA), trial registration ACTRN12622001523796 (Date registered 8th December 2022). Methods: In 36 consecutively-enrolled patients (57 ± 11 years, 69% male) with symptomatic paroxysmal ( n = 22) and persistent ( n = 14) AF, pulmonary vein isolation (PVI) was performed using this catheter, guided by 3D mapping. All patients underwent remapping at 3 months to confirm PVI durability. Patients were followed at 6 and 12 months with clinical review, Holter monitoring and electrocardiography. The primary efficacy and safety endpoints included a freedom from recurrent AF at 12 months > 50% and serious adverse events (SAE) at 7 and 30 days < 5%, respectively. The secondary efficacy endpoints included 3-month PVI durability > 50% and 6-month freedom from AF > 60%. Results: All endpoints were achieved in the entire study cohort. There was 1 SAE (renal impairment which resolved with conservative management) with a total SAE rate of 2.8%. One patient was lost to follow-up at 12 months with a primary efficacy endpoint of 92% (32/35 patients). The secondary efficacy endpoints were 82% 3-month PVI and 94% (34/36 patients) 6-month freedom from AF. During the study, the PFA dose was adjusted in 3 cohorts. The “optimized subset” had 100% PVI durability and freedom from AF at 6 and 12 months without SAEs. Conclusion: This study of a novel PFA catheter system for ablation of paroxysmal and persistent AF achieved all predetermined primary and secondary clinical endpoints.
- 17 September 2026
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (6) , 1481-1491
Open AccessFirst-in-human experience from RESET-AF (Rapid onE-Shot Electroporation Trial for Atrial Fibrillation)
Background and Aims: Pulsed field ablation (PFA) is increasingly used to treat patients with atrial fibrillation (AF). The RESET-AF was a single-arm, first-in-human, clinical trial of AF ablation using a novel, single-shot PFA system (ElePulse ® , CRC EP, Tustin, CA, USA), trial registration ACTRN12622001523796 (Date registered 8th December 2022). Methods: In 36 consecutively-enrolled patients (57 ± 11 years, 69% male) with symptomatic paroxysmal ( n = 22) and persistent ( n = 14) AF, pulmonary vein isolation (PVI) was performed using this catheter, guided by 3D mapping. All patients underwent remapping at 3 months to confirm PVI durability. Patients were followed at 6 and 12 months with clinical review, Holter monitoring and electrocardiography. The primary efficacy and safety endpoints included a freedom from recurrent AF at 12 months > 50% and serious adverse events (SAE) at 7 and 30 days < 5%, respectively. The secondary efficacy endpoints included 3-month PVI durability > 50% and 6-month freedom from AF > 60%. Results: All endpoints were achieved in the entire study cohort. There was 1 SAE (renal impairment which resolved with conservative management) with a total SAE rate of 2.8%. One patient was lost to follow-up at 12 months with a primary efficacy endpoint of 92% (32/35 patients). The secondary efficacy endpoints were 82% 3-month PVI and 94% (34/36 patients) 6-month freedom from AF. During the study, the PFA dose was adjusted in 3 cohorts. The “optimized subset” had 100% PVI durability and freedom from AF at 6 and 12 months without SAEs. Conclusion: This study of a novel PFA catheter system for ablation of paroxysmal and persistent AF achieved all predetermined primary and secondary clinical endpoints.
- Open Access
- 9 December 2021
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (1) , 106-114
Ablation of typical atrial flutter using mini electrode measurements for maximum voltage‐guided ablation: A randomized, controlled trial
Background Novel ablation catheters with mini electrode (ME) sensing have become available but their utility is unclear. We investigated whether ablation of the cavotricuspid isthmus (CTI) for atrial flutter (AFL) would be improved using ME signals. Methods Sixty-one patients (76% male, 63 ± 10 years) with CTI-dependent AFL underwent ablation using a maximum voltage-guided approach, randomized to either standard 8 mm non-irrigated catheter with bipolar signals or IntellaTip MiFi catheter using ME signals alone. Results Acute bidirectional block was achieved in 97%. Mean follow-up was 16.7 ± 10 months. The median number of ablation lesions was 13 in both groups (range 3–62 vs. 1–43, p = .85). No significant differences were observed in AFL recurrences (17% vs. 11%, p = .7), median procedure durations (97 min [interquartile range (IQR), 71–121] vs. 87 min [IQR, 72–107], p = .55) or fluoroscopy times (31 min [IQR, 21–52] vs. 38 min [IQR, 25–70], p = .56). Amplitudes of ME signals were on average 160% greater than blinded bipolar signals. In 23.7% of lesions where bipolar signals were difficult to interpret, 13.6% showed a clear ME signal. Conclusions There was no difference in the effectiveness of CTI ablation guided by ME signals, compared with using bipolar signals from a standard 8 mm ablation catheter. While ME signal amplitudes were larger and sometimes present when the bipolar signal was unclear, this did not improve procedural characteristics or outcomes. The results suggest future research should focus on lesion integrity rather than signal sensing.
- 9 December 2021
- Published by Wiley in Journal of Arrhythmia
- Vol. 38 (1) , 106-114
Open AccessAblation of typical atrial flutter using mini electrode measurements for maximum voltage‐guided ablation: A randomized, controlled trial
Background Novel ablation catheters with mini electrode (ME) sensing have become available but their utility is unclear. We investigated whether ablation of the cavotricuspid isthmus (CTI) for atrial flutter (AFL) would be improved using ME signals. Methods Sixty-one patients (76% male, 63 ± 10 years) with CTI-dependent AFL underwent ablation using a maximum voltage-guided approach, randomized to either standard 8 mm non-irrigated catheter with bipolar signals or IntellaTip MiFi catheter using ME signals alone. Results Acute bidirectional block was achieved in 97%. Mean follow-up was 16.7 ± 10 months. The median number of ablation lesions was 13 in both groups (range 3–62 vs. 1–43, p = .85). No significant differences were observed in AFL recurrences (17% vs. 11%, p = .7), median procedure durations (97 min [interquartile range (IQR), 71–121] vs. 87 min [IQR, 72–107], p = .55) or fluoroscopy times (31 min [IQR, 21–52] vs. 38 min [IQR, 25–70], p = .56). Amplitudes of ME signals were on average 160% greater than blinded bipolar signals. In 23.7% of lesions where bipolar signals were difficult to interpret, 13.6% showed a clear ME signal. Conclusions There was no difference in the effectiveness of CTI ablation guided by ME signals, compared with using bipolar signals from a standard 8 mm ablation catheter. While ME signal amplitudes were larger and sometimes present when the bipolar signal was unclear, this did not improve procedural characteristics or outcomes. The results suggest future research should focus on lesion integrity rather than signal sensing.
- Open Access
- 1 May 2020
- Published by Elsevier in Journal of Electrocardiology
- Vol. 60, 118-125
Miniaturized implantable cardiac monitor with a long sensing vector (BIOMONITOR III): Insertion procedure assessment, sensing performance, and home monitoring transmission success
- 1 May 2020
- Published by Elsevier in Journal of Electrocardiology
- Vol. 60, 118-125
Open AccessMiniaturized implantable cardiac monitor with a long sensing vector (BIOMONITOR III): Insertion procedure assessment, sensing performance, and home monitoring transmission success
- 25 October 2016
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (12) , 1429-1436
Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter
This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.
- 25 October 2016
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (12) , 1429-1436
Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter
This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.
- 29 July 2015
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 25 (2) , 140-147
Characterisation and Comparison of Acute Haemodynamic, Cardiac Biochemical and Hormonal Response to Different Ventricular Pacing Sites in the Normal Heart
- 29 July 2015
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 25 (2) , 140-147
Characterisation and Comparison of Acute Haemodynamic, Cardiac Biochemical and Hormonal Response to Different Ventricular Pacing Sites in the Normal Heart
- Open Access
- 1 July 2015
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 15 (4) , 216-219
Acute transient non-physiological over-sensing in the ventricle with a DF4 lead
- 1 July 2015
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 15 (4) , 216-219
Open AccessAcute transient non-physiological over-sensing in the ventricle with a DF4 lead