Determination of NIR informative wavebands for transmission non-invasive blood glucose measurement using a Fourier transform spectrometer
Open Access
- 1 March 2018
- journal article
- conference paper
- Published by AIP Publishing in AIP Advances
- Vol. 8 (3) , 035216
Abstract
Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900∼1450 nm) and the first overtone band (1450∼1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject’s finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.Keywords
Funding Information
- Science and Technology Innovation Foundation of Shenzhen (JSGG20160229115138818)
- Science and Technology Innovation Foundation of Shenzhen (ZDSYS201604211455119)
This publication has 24 references indexed in Scilit:
- Discussion on the validity of NIR spectral data in non-invasive blood glucose sensingBiomedical Optics Express, 2013
- A Reference-Wavelength-Based Method for Improved Analysis of Near-Infrared SpectroscopyApplied Spectroscopy, 2009
- Wavelength Selection for Multivariate Calibration Using Tikhonov RegularizationApplied Spectroscopy, 2007
- Noninvasive Near-Infrared Blood Glucose Monitoring Using a Calibration Model Built by a Numerical Simulation Method: Trial Application to Patients in an Intensive Care UnitApplied Spectroscopy, 2006
- Removal of Interference Signals Due to Water from in vivo Near-Infrared (NIR) Spectra of Blood Glucose by Region Orthogonal Signal Correction (ROSC)Analytical Sciences, 2004
- Simultaneous determination of human serum albumin, γ-globulin, and glucose in a phosphate buffer solution by near-infrared spectroscopy with moving window partial least-squares regressionThe Analyst, 2003
- Short-Wavelength Near-Infrared Spectra of Sucrose, Glucose, and Fructose with Respect to Sugar Concentration and TemperatureApplied Spectroscopy, 2003
- Near-Infrared Spectroscopic Measurement of Physiological Glucose Levels in Variable Matrices of Protein and TriglyceridesAnalytical Chemistry, 1996
- Non-invasive glucose monitoringCurrent Opinion in Biotechnology, 1996
- Near-infrared spectroscopic measurement of glucose in a protein matrixAnalytical Chemistry, 1993