Performance and suitability of polymerase chain reaction for early detection of bacteria in platelet concentrates
- 10 March 2011
- journal article
- Published by Wiley in Transfusion
- Vol. 51 (9) , 2006-2011
Abstract
In this study the applicability of a 16S rRNA real-time reverse transcriptase polymerase chain reaction (RT-PCR) and a Staphylococcus genus-specific PCR for screening of bacterial contamination in platelet concentrates (PCs) was determined. A total of 336 sample bags, from PCs that were routinely tested in the BacT/ALERT (bioMérieux), were collected and frozen until testing by the PCR assays. Based on the BacT/ALERT results, 107 PCs were positive and 229 were negative for bacterial growth. The analytical sensitivity of the 16S rRNA real-time RT-PCR ranged from 5 to 40 colony-forming units (CFUs)/mL. The PCR detected five positive samples, four of which were also positive in the BacT/ALERT. The sensitivity of the test was 3.8%, and the specificity was 99.5%. The analytical sensitivity of the Staphylococcus genus-specific PCR ranged from 5 to 15 CFUs/mL. Thirty-nine units that were BacT/ALERT positive for staphylococci were tested with this PCR. Six samples were positive with the PCR, five of which were also BacT/ALERT positive. The sensitivity of the Staphylococcus genus-specific PCR was 12.8%, and the specificity was 98.8%. Despite the rapid availability of results compared to the BacT/ALERT, the analytical sensitivity of a generic or specific PCR assay is not high enough to be an alternative for the BacT/ALERT when PCs are screened on the day of production.Keywords
This publication has 14 references indexed in Scilit:
- Development of a reverse transcription–polymerase chain reaction assay for eubacterial RNA detection in platelet concentratesTransfusion, 2010
- BLOOD COMPONENTS: Screening of single‐donor apheresis platelets for bacterial contamination: the PASSPORT study resultsTransfusion, 2010
- Bacterial screening of platelet concentrates: results of 2 years active surveillance of transfused positive cultured units released as negative to dateVox Sanguinis, 2009
- Screening of platelet concentrates for bacterial contamination: spectrum of bacteria detected, proportionof transfused units, and clinical follow-upAnnals of Hematology, 2009
- Fatal group C streptococcal infection due to transfusion of a bacterially contaminated pooled platelet unit despite routine bacterial culture screeningTransfusion, 2008
- Propionibacterium acnes lacks the capability to proliferate in platelet concentratesVox Sanguinis, 2007
- Detection of bacteria in platelet concentrates prepared from spiked single donations using cultural and molecular genetic methodsTransfusion Medicine, 2007
- Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the NetherlandsTransfusion, 2006
- Six years’ experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false‐negative resultsVox Sanguinis, 2005
- Platelet Concentrates Stored in Plasma for 72 Hours at 22°C Prepared from Buffycoats of Citrate‐Phosphate‐Dextrose Blood Collected in a Quadruple‐Bag Saline‐Adenine‐Glucose‐Mannitol SystemVox Sanguinis, 1985