Temporal subtraction in chest radiography: Automated assessment of registration accuracy
Authors:
- Samuel G. ArmatoSASamuel G. Armato
- Devang J. DoshiDDDevang J. Doshi
- Roger EngelmannRERoger Engelmann
- Charles L. CroteauCCCharles L. Croteau
- Heber MacMahonHMHeber MacMahon
- 14 April 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (5) , 1239-1249
Abstract
Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a "temporal subtraction image." Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from "5-excellent" to "1-poor;" ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a "lung mask" region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A(z) value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A(z) value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest radiography.Keywords
Funding Information
- U.S. Public Health Service (EB00341)
This publication has 11 references indexed in Scilit:
- Temporal Subtraction for the Detection of Hazy Pulmonary Opacities on Chest RadiographyAmerican Journal of Roentgenology, 2002
- Improved Detection of Lung Nodules by Using a Temporal Subtraction TechniqueRadiology, 2002
- Temporal Subtraction for Detection of Solitary Pulmonary Nodules on Chest Radiographs: Evaluation of a Commercially Available Computer-aided Diagnosis SystemRadiology, 2002
- ROC Analysis of Detection of Metastatic Pulmonary Nodules on Digital Chest Radiographs with Temporal SubtractionAcademic Radiology, 2001
- Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiographyJournal of Digital Imaging, 1999
- Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval changeMedical Physics, 1999
- Application of temporal subtraction for detection of interval changes on chest radiographs: Improvement of subtraction images using automated initial image matchingJournal of Digital Imaging, 1999
- Digital chest radiography: effect of temporal subtraction images on detection accuracy.Radiology, 1997
- Digital image subtraction of temporally sequential chest images for detection of interval changeMedical Physics, 1994
- ROC Methodology in Radiologic ImagingInvestigative Radiology, 1986