HMHeber MacMahon

Heber MacMahon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Heber MacMahon has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Samuel G. Armato

    The University of Chicago, Department of Radiology, Chicago, Illinois, United States

    4 shared publications
  • Maryellen Lissak Giger

    The University of Chicago, Department of Radiology, Chicago, Illinois, United States

    3 shared publications
  • Roger Engelmann

    Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637

    3 shared publications
  • Alexander A. Bankier

    From the Department of Radiology, University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637 (H.M.); Department of Radiology, New York University Langone Medical Center, New York, NY (D.P.N.); Department of Radiology, Seoul National University College of Medicine, Seoul, South Korea (J.M.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South...

    1 shared publication
  • Ann N. C. Leung

    From the Department of Radiology, University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637 (H.M.); Department of Radiology, New York University Langone Medical Center, New York, NY (D.P.N.); Department of Radiology, Seoul National University College of Medicine, Seoul, South Korea (J.M.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South...

    1 shared publication
  • Atul C. Mehta

    From the Department of Radiology, University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637 (H.M.); Department of Radiology, New York University Langone Medical Center, New York, NY (D.P.N.); Department of Radiology, Seoul National University College of Medicine, Seoul, South Korea (J.M.G.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South...

    1 shared publication

Latest Publications

  • Deep convolutional neural networks in the classification of dual-energy thoracic radiographic views for efficient workflow: analysis on over 6500 clinical radiographs

    by Jennie Crosby, Thomas Rhines, Feng Li, Heber MacMahon, Maryellen Giger

    DICOM header information is frequently used to classify medical image types; however, if a header is missing fields or contains incorrect data, the utility is limited. To expedite image classification, we trained convolutional neural networks (CNNs) in two classification tasks for thoracic radiographic views obtained from dual-energy studies: (a) distinguishing between frontal, lateral, soft tissue, and bone images and (b) distinguishing between posteroanterior (PA) or anteroposterior (AP) chest radiographs. CNNs with AlexNet architecture were trained from scratch. 1910 manually classified radiographs were used for training the network to accomplish task (a), then tested with an independent test set (3757 images). Frontal radiographs from the two datasets were combined to train a network to accomplish task (b); tested using an independent test set of 1000 radiographs. ROC analysis was performed for each trained CNN with area under the curve (AUC) as a performance metric. Classification between frontal images (AP/PA) and other image types yielded an AUC of 0.997 [95% confidence interval (CI): 0.996, 0.998]. Classification between PA and AP radiographs resulted in an AUC of 0.973 (95% CI: 0.961, 0.981). CNNs were able to rapidly classify thoracic radiographs with high accuracy, thus potentially contributing to effective and efficient workflow.


  • Top Cited Papers

    Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017

    by Heber MacMahon, David P. Naidich, Jin Mo Goo, Kyung Soo Lee, Ann N. C. Leung, John R. Mayo, Atul C. Mehta, Yoshiharu Ohno, Charles A. Powell, Mathias Prokop, et al.

    The minimum threshold size for routine follow-up has been increased, and recommended follow-up intervals are now given as a range rather than as a precise time period to give radiologists, clinicians, and patients greater discretion to accommodate individual risk factors and preferences. The Fleischner Society Guidelines for management of solid nodules were published in 2005, and separate guidelines for subsolid nodules were issued in 2013. Since then, new information has become available; therefore, the guidelines have been revised to reflect current thinking on nodule management. The revised guidelines incorporate several substantive changes that reflect current thinking on the management of small nodules. The minimum threshold size for routine follow-up has been increased, and recommended follow-up intervals are now given as a range rather than as a precise time period to give radiologists, clinicians, and patients greater discretion to accommodate individual risk factors and preferences. The guidelines for solid and subsolid nodules have been combined in one simplified table, and specific recommendations have been included for multiple nodules. These guidelines represent the consensus of the Fleischner Society, and as such, they incorporate the opinions of a multidisciplinary internat...


  • Digital Radiography

    by Heber MacMahon

  • Temporal subtraction in chest radiography: Mutual information as a measure of image quality

    by Samuel G. Armato, William F. Sensakovic, Samantha J. Passen, Roger Engelmann, Heber MacMahon

    Purpose: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or “lung mask,” of a previous radiographicimage to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images. Methods: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist’s subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%–60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. Results: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average A z value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. Conclusions: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.


  • Dual Energy Subtraction and Temporal Subtraction Chest Radiography

    by Heber MacMahon, Feng Li, Roger Engelmann, Rachael Roberts, Samuel Armato

    Digital radiography and display systems have revolutionized radiologic practice in recent years and have enabled clinical application of advanced image processing techniques. These include dual energy subtraction and temporal subtraction, both of which can improve diagnostic accuracy for abnormal findings in chest radiographs, especially for subtle lesions such as early lung cancer or focal pneumonia. Dual energy radiography exploits the differential attenuation of low-energy x-ray photons by calcium to produce separate images on the bones and soft tissues, which provides improved detection and characterization of both calcified and noncalcified lung lesions. Dual energy subtraction radiography is currently available from 2 of the major vendors and is in clinical use at many institutions in the United States. Temporal subtraction is a complementary technique that enhances interval change, by using a previous radiograph as a subtraction mask, so that unchanged normal anatomy is suppressed, whereas new abnormalities are enhanced. Though it is not yet a product in the United States, temporal subtraction is available for clinical use in Japan. Temporal subtraction can be combined with energy subtraction to reduce misregistration artifacts, and also has potential to improve computer-aided detection of nodules and other types of lung disease.


  • Temporal subtraction in chest radiography: Automated assessment of registration accuracy

    by Samuel G. Armato, Devang J. Doshi, Roger Engelmann, Charles L. Croteau, Heber MacMahon

    Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a "temporal subtraction image." Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from "5-excellent" to "1-poor;" ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a "lung mask" region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A(z) value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A(z) value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest radiography.


  • Automated detection of lung nodules in CT scans: Preliminary results

    by Samuel G. Armato, Maryellen L. Giger, Heber MacMahon

    We have developed a fully automated computerized method for the detection of lung nodules in helical computed tomography (CT) scans of the thorax. This method is based on two-dimensional and three-dimensional analyses of the image data acquired during diagnostic CT scans. Lung segmentation proceeds on a section-by-section basis to construct a segmented lung volume within which further analysis is performed. Multiple gray-level thresholds are applied to the segmented lung volume to create a series of thresholded lung volumes. An 18-point connectivity scheme is used to identify contiguous three-dimensional structures within each thresholded lung volume, and those structures that satisfy a volume criterion are selected as initial lung nodule candidates. Morphological and gray-level features are computed for each nodule candidate. After a rule-based approach is applied to greatly reduce the number of nodule candidates that corresponds to nonnodules, the features of remaining candidates are merged through linear discriminant analysis. The automated method was applied to a database of 43 diagnostic thoracic CT scans. Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate nodule candidates that correspond to actual nodules from false-positive candidates. The area under the ROC curve for this categorization task attained a value of 0.90 during leave-one-out-by-case evaluation. The automated method yielded an overall nodule detection sensitivity of 70% with an average of 1.5 false-positive detections per section when applied to the complete 43-case database. A corresponding nodule detection sensitivity of 89% with an average of 1.3 false-positive detections per section was achieved with a subset of 20 cases that contained only one or two nodules per case.


  • Computerized detection of abnormal asymmetry in digital chest radiographs

    by Samuel G. Armato, Maryellen L. Giger, Heber MacMahon