Tommy Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tommy Peng has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
- Maureen J. Shader
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, USA
7 shared publications - Colette M. McKay
The Bionics Institute, 41 Victoria Parade, Fitzroy, 3065, Victoria, Australia; Department of Medical Bionics, the University of Melbourne, Grattan Street, Parkville, 3010, Victoria, Australia
6 shared publications Mica Haneman
The Bionics Institute, Melbourne, Australia
5 shared publicationsRobert Luke
The Bionics Institute, Melbourne, Australia
5 shared publications- Jamal Esmaelpoor
Bionics Institute, Fitzroy, VIC 3065, Australia
4 shared publications - Beth Jelfs
Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Birmingham B15 2FG, U.K.
3 shared publications
Latest Publications
- 7 October 2026
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 47 (6) , 1552-1562
Auditory- and Visual-Speech Evoked Activation of the Superior Temporal Gyrus Contralateral to the Cochlear Implant Predicts Speech Recognition Outcomes
Objectives: Speech recognition outcomes vary widely in cochlear implant recipients, but the reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganization after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech recognition outcomes and stimulus-evoked activation of cortical language processing areas. Design: Forty-three newly implanted post-lingually deaf adult cochlear implant recipients (17 female, mean age at implantation: 58.5 yr, SD: 14.4 yr) were recruited for the longitudinal study. Participants attended two research visits: the first conducted within 1 mo of device switch-on, and the second conducted 1 yr after device switch-on. At each visit, we evaluated speech recognition outcomes in noise and cortical activation using functional near-infrared spectroscopy during a passive listening task, during which a story was told in either an auditory- or visual-speech (lipreading) condition. Results: We found consistent negative correlations between speech understanding outcomes at 1 yr and activation of the superior temporal gyrus at 1 mo in response to both auditory and visual speech. These associations were not observed for activation measured at 1 yr. Subgroup regression analysis revealed that these correlations were most consistently seen in the superior temporal gyrus contralateral to the cochlear implant. Activation in the superior temporal gyrus contralateral to the implant at 1 mo also explained additional variance in speech outcomes at 1 yr beyond clinical factors alone. However, longitudinal analysis showed no association between within-subject changes in activation and changes in speech understanding outcomes within this first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within 1 mo after device switch-on and speech recognition outcomes at 1 yr can potentially enable triaging of recipients to improve clinical management of implant recipients.
- 7 October 2026
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 47 (6) , 1552-1562
Auditory- and Visual-Speech Evoked Activation of the Superior Temporal Gyrus Contralateral to the Cochlear Implant Predicts Speech Recognition Outcomes
Objectives: Speech recognition outcomes vary widely in cochlear implant recipients, but the reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganization after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech recognition outcomes and stimulus-evoked activation of cortical language processing areas. Design: Forty-three newly implanted post-lingually deaf adult cochlear implant recipients (17 female, mean age at implantation: 58.5 yr, SD: 14.4 yr) were recruited for the longitudinal study. Participants attended two research visits: the first conducted within 1 mo of device switch-on, and the second conducted 1 yr after device switch-on. At each visit, we evaluated speech recognition outcomes in noise and cortical activation using functional near-infrared spectroscopy during a passive listening task, during which a story was told in either an auditory- or visual-speech (lipreading) condition. Results: We found consistent negative correlations between speech understanding outcomes at 1 yr and activation of the superior temporal gyrus at 1 mo in response to both auditory and visual speech. These associations were not observed for activation measured at 1 yr. Subgroup regression analysis revealed that these correlations were most consistently seen in the superior temporal gyrus contralateral to the cochlear implant. Activation in the superior temporal gyrus contralateral to the implant at 1 mo also explained additional variance in speech outcomes at 1 yr beyond clinical factors alone. However, longitudinal analysis showed no association between within-subject changes in activation and changes in speech understanding outcomes within this first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within 1 mo after device switch-on and speech recognition outcomes at 1 yr can potentially enable triaging of recipients to improve clinical management of implant recipients.
- Open Access
Beyond Single Biomarkers: A Graph Neural Network Framework for Multivariable Prediction of Clinical Outcomes from Brain Imaging
Understanding brain–behavior relationships requires models capturing the distributed, interactive, and multiscale nature of neural systems. Traditional univariate approaches and single-biomarker models are inherently limited in this context, as they fail to represent dependencies across regions and the hierarchical organization of brain networks. In this study, we propose a graph-based multivariable framework for brain imaging analysis that integrates key organizational principles of brain function—including segregation, integration, modularity, and temporal dynamics—within a unified graph neural network architecture. The framework represents brain data as hierarchical graphs, where node features encode regional activation and temporal variability, and graph structure captures interactions within and between functional modules. The proposed approach is evaluated using functional near-infrared spectroscopy (fNIRS) data as a case study, where subject-specific brain graphs are constructed from task-based recordings acquired shortly after cochlear implant activation to predict speech understanding outcomes one year later. Under leave-one-subject-out validation, the model demonstrates strong predictive performance (R = 0.73, p < 0.001), outperforming previously reported single-biomarker approaches. Perturbation-based analyses further show that predictions are driven by distributed patterns of activity and interaction across regions and modalities, rather than isolated features. These results illustrate the capability of the proposed framework to capture complex brain organization and highlight its potential as a generalizable platform for multivariable analysis and prediction in neuroimaging applications beyond the specific clinical use case considered here.
Open AccessBeyond Single Biomarkers: A Graph Neural Network Framework for Multivariable Prediction of Clinical Outcomes from Brain Imaging
Understanding brain–behavior relationships requires models capturing the distributed, interactive, and multiscale nature of neural systems. Traditional univariate approaches and single-biomarker models are inherently limited in this context, as they fail to represent dependencies across regions and the hierarchical organization of brain networks. In this study, we propose a graph-based multivariable framework for brain imaging analysis that integrates key organizational principles of brain function—including segregation, integration, modularity, and temporal dynamics—within a unified graph neural network architecture. The framework represents brain data as hierarchical graphs, where node features encode regional activation and temporal variability, and graph structure captures interactions within and between functional modules. The proposed approach is evaluated using functional near-infrared spectroscopy (fNIRS) data as a case study, where subject-specific brain graphs are constructed from task-based recordings acquired shortly after cochlear implant activation to predict speech understanding outcomes one year later. Under leave-one-subject-out validation, the model demonstrates strong predictive performance (R = 0.73, p < 0.001), outperforming previously reported single-biomarker approaches. Perturbation-based analyses further show that predictions are driven by distributed patterns of activity and interaction across regions and modalities, rather than isolated features. These results illustrate the capability of the proposed framework to capture complex brain organization and highlight its potential as a generalizable platform for multivariable analysis and prediction in neuroimaging applications beyond the specific clinical use case considered here.
- Open Access
- 15 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (51)
Dynamic functional connectivity following cochlear implantation: Predicting speech outcomes and exploring brain network dynamics
Cochlear implants (CIs) have transformed hearing restoration for individuals with severe or profound hearing loss, yet outcomes vary widely and remain difficult to predict. This study introduces an approach by examining the temporal dynamics of brain functional networks postimplantation to identify predictors of outcomes and explore brain plasticity. Twenty-nine CI candidates and 23 normal-hearing individuals participated. Functional near-infrared spectroscopy measured brain activity during audio-only and visual-only speech tasks at 1 mo and 1 y postimplantation, with speech understanding assessed after 1 y. Brain community dynamics were analyzed using multilayer modularity and network switching rates to capture temporal reorganization. Lower network switching rates shortly after implantation were associated with better long-term speech performance. Evidence of cross-modal plasticity—reflecting preimplant neural reorganization—was observed in early recordings, indicated by increased module allegiance between the posterior temporal (PT) region and visual cortices, which diminished after 1 y. Additionally, interhemispheric connectivity in the PT showed significant improvement between sessions, reducing disparities between CI users and normal-hearing individuals. These findings highlight dynamic functional connectivity as a meaningful neural correlate of outcome variability, with potential relevance for guiding personalized rehabilitation strategies and optimizing auditory and speech outcomes.
- 15 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (51)
Open AccessDynamic functional connectivity following cochlear implantation: Predicting speech outcomes and exploring brain network dynamics
Cochlear implants (CIs) have transformed hearing restoration for individuals with severe or profound hearing loss, yet outcomes vary widely and remain difficult to predict. This study introduces an approach by examining the temporal dynamics of brain functional networks postimplantation to identify predictors of outcomes and explore brain plasticity. Twenty-nine CI candidates and 23 normal-hearing individuals participated. Functional near-infrared spectroscopy measured brain activity during audio-only and visual-only speech tasks at 1 mo and 1 y postimplantation, with speech understanding assessed after 1 y. Brain community dynamics were analyzed using multilayer modularity and network switching rates to capture temporal reorganization. Lower network switching rates shortly after implantation were associated with better long-term speech performance. Evidence of cross-modal plasticity—reflecting preimplant neural reorganization—was observed in early recordings, indicated by increased module allegiance between the posterior temporal (PT) region and visual cortices, which diminished after 1 y. Additionally, interhemispheric connectivity in the PT showed significant improvement between sessions, reducing disparities between CI users and normal-hearing individuals. These findings highlight dynamic functional connectivity as a meaningful neural correlate of outcome variability, with potential relevance for guiding personalized rehabilitation strategies and optimizing auditory and speech outcomes.
- Open Access
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Longitudinal speech understanding outcomes in cochlear implant recipients are associated with neural factors identified using psychophysics and functional brain imaging
Objective: There remain large variations in cochlear implant outcomes which are poorly explained by patient history factors. This study aims to better understand how different neural limitations along the auditory processing pathway are associated with speech understanding outcomes.Design: 43 cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical “spectral tilt”. At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near infra-red spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at one-year post device switch-on.Results: We found that greater abilities to discriminate smaller across-electrode stimulation intensities (R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex (R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009).Conclusion: The results suggest that recipient-specific neural factors contribute significantly towards individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Open AccessLongitudinal speech understanding outcomes in cochlear implant recipients are associated with neural factors identified using psychophysics and functional brain imaging
Objective: There remain large variations in cochlear implant outcomes which are poorly explained by patient history factors. This study aims to better understand how different neural limitations along the auditory processing pathway are associated with speech understanding outcomes.Design: 43 cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical “spectral tilt”. At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near infra-red spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at one-year post device switch-on.Results: We found that greater abilities to discriminate smaller across-electrode stimulation intensities (R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex (R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009).Conclusion: The results suggest that recipient-specific neural factors contribute significantly towards individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.
- Open Access
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Auditory- and visual-speech evoked activation of the superior temporal gyrus contralateral to the cochlear implant predicts speech understanding outcomes
Objective: Speech discrimination outcomes vary widely in cochlear implant recipients, but reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganisation after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech understanding outcomes and stimulus evoked activation of cortical language processing areas. Design: 43 newly implanted post-lingually deaf adult cochlear implant recipients were recruited to the longitudinal study. Participants attended two research visits: the first conducted within one-month of device switch-on, and the second conducted one-year after device switch-on. At each visit, we evaluated speech understanding outcomes in noise and cortical activation using functional near infrared spectroscopy during a passive listening task, during which a story was told in either an auditory or visual-speech (lip-reading) condition. Results: We found statistically significant correlations between poorer speech understanding outcomes one year post device switch-on and large activations in the superior temporal gyrus contralateral to the device in response to both auditory- (F(1, 30) = 11.297, R2 = 0.274, p = 0.002) and visual-speech (F(1, 30) = 18.216, R2 = 0.38, p < 0.001) stimuli tested within one-month of switch-on. However, these significant associations were not observed using activation data from the one-year mark. Furthermore, we found no association between changes in activation of the superior temporal gyrus contralateral to the device and changes in speech understanding outcomes over the first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within one-month after device switch-on and speech understanding outcomes at one-year can potentially enable triaging of recipients to improve clinical management of implant recipients.
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Open AccessAuditory- and visual-speech evoked activation of the superior temporal gyrus contralateral to the cochlear implant predicts speech understanding outcomes
Objective: Speech discrimination outcomes vary widely in cochlear implant recipients, but reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganisation after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech understanding outcomes and stimulus evoked activation of cortical language processing areas. Design: 43 newly implanted post-lingually deaf adult cochlear implant recipients were recruited to the longitudinal study. Participants attended two research visits: the first conducted within one-month of device switch-on, and the second conducted one-year after device switch-on. At each visit, we evaluated speech understanding outcomes in noise and cortical activation using functional near infrared spectroscopy during a passive listening task, during which a story was told in either an auditory or visual-speech (lip-reading) condition. Results: We found statistically significant correlations between poorer speech understanding outcomes one year post device switch-on and large activations in the superior temporal gyrus contralateral to the device in response to both auditory- (F(1, 30) = 11.297, R2 = 0.274, p = 0.002) and visual-speech (F(1, 30) = 18.216, R2 = 0.38, p < 0.001) stimuli tested within one-month of switch-on. However, these significant associations were not observed using activation data from the one-year mark. Furthermore, we found no association between changes in activation of the superior temporal gyrus contralateral to the device and changes in speech understanding outcomes over the first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within one-month after device switch-on and speech understanding outcomes at one-year can potentially enable triaging of recipients to improve clinical management of implant recipients.
- 8 January 2025
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 26 (1) , 77-91
Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs)
Purpose Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences. Methods Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes. Results At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R2 = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R2 = 0.499, p < 0.01), no significant association was found between variations in PECAP’s neural health estimates and phoneme speech scores (R2 = 0.082, p = 0.366). Conclusion Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.
- 8 January 2025
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 26 (1) , 77-91
Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs)
Purpose Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences. Methods Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes. Results At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R2 = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R2 = 0.499, p < 0.01), no significant association was found between variations in PECAP’s neural health estimates and phoneme speech scores (R2 = 0.082, p = 0.366). Conclusion Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.
- Open Access
- 24 September 2024
- Published by Center for Open Science in MetaArXiv
The fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research
In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.
- 24 September 2024
- Published by Center for Open Science in MetaArXiv
Open AccessThe fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research
In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.
- Open Access
- 24 September 2024
- Published by Center for Open Science in MetaArXiv
The fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research
In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.
- 24 September 2024
- Published by Center for Open Science in MetaArXiv
Open AccessThe fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research
In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.
- Open Access
Cross-modal Functional Plasticity after Cochlear-implantation
Objective: Despite evidence that cross-modal effects after hearing loss and cochlear implantation are primarily conveyed through synaptic gain and efficacy rather than reorganized fiber tracts, few studies have assessed cross-modal functional connectivity (CMFC) to evaluate plasticity. This study, inspired by the psychophysiological interactions (PPI) method, addresses its limitations and provides a robust approach to evaluating task-induced CMFC. Design: Twenty-two post-lingually deafened, newly implanted adult cochlear implant (CI) recipients with severe hearing loss in the contralateral ear and 17 normal-hearing (NH) subjects participated. The experiment included audio-only and visual-only speech tasks, with resting-state FC as a baseline. Functional near-infrared spectroscopy (fNIRS) measured brain imaging data one month and one year post-implantation. CI users’ speech understanding performance was evaluated one year after implantation. Results: A negative correlation was found between average contralateral task-induced CMFC and speech outcomes, particularly in links from the angular gyrus (AG), both one month and one year post-activation. Plastic changes showed higher task-induced CMFC in AG compared to the superior temporal gyrus (STG), aligning with neural efficiency principles. Task-induced CMFC remained elevated in CI users compared to NH cohorts even after one year. Conclusion: Task-induced CMFC can serve as a significant marker of cross-modal plasticity and speech performance in CI recipients, indicating increased reliance on cross-modal processing in one year after implantation.
Open AccessCross-modal Functional Plasticity after Cochlear-implantation
Objective: Despite evidence that cross-modal effects after hearing loss and cochlear implantation are primarily conveyed through synaptic gain and efficacy rather than reorganized fiber tracts, few studies have assessed cross-modal functional connectivity (CMFC) to evaluate plasticity. This study, inspired by the psychophysiological interactions (PPI) method, addresses its limitations and provides a robust approach to evaluating task-induced CMFC. Design: Twenty-two post-lingually deafened, newly implanted adult cochlear implant (CI) recipients with severe hearing loss in the contralateral ear and 17 normal-hearing (NH) subjects participated. The experiment included audio-only and visual-only speech tasks, with resting-state FC as a baseline. Functional near-infrared spectroscopy (fNIRS) measured brain imaging data one month and one year post-implantation. CI users’ speech understanding performance was evaluated one year after implantation. Results: A negative correlation was found between average contralateral task-induced CMFC and speech outcomes, particularly in links from the angular gyrus (AG), both one month and one year post-activation. Plastic changes showed higher task-induced CMFC in AG compared to the superior temporal gyrus (STG), aligning with neural efficiency principles. Task-induced CMFC remained elevated in CI users compared to NH cohorts even after one year. Conclusion: Task-induced CMFC can serve as a significant marker of cross-modal plasticity and speech performance in CI recipients, indicating increased reliance on cross-modal processing in one year after implantation.
- Open Access
Resting-state Functional Connectivity Predicts Cochlear-Implant Speech Outcomes
Background: Cochlear implants (CIs) have revolutionized hearing restoration for individuals with severe or profound hearing loss. However, a substantial and unexplained variability persists in CI outcomes, even when considering subject-specific factors such as age and the duration of deafness. In this study, we explore the utility of resting-state functional near-infrared spectroscopy (fNIRS) recordings to predict speech understanding outcomes before and after CI implantation. Our hypothesis revolves around resting-state functional connectivity (FC) as a reflection of brain plasticity post-hearing loss and implantation. Specifically, we hypothesized that the average clustering coefficient in resting FC networks can capture this variation among CI users. Methods: Twenty-two cochlear implant candidates participated in this study. Resting-state fNIRS data were collected pre-implantation and at one month, three months, and one year post-implantation. Speech understanding performance was assessed using CNC words in quiet and BKB sentences in noise one year post-implantation. Resting-state functional connectivity networks were constructed using regularized partial correlation, and the average clustering coefficient was measured in the signed weighted networks as a predictive measure for implantation outcomes. Results: Our findings demonstrate a significant correlation between the average clustering coefficient in resting-state functional networks and speech understanding outcomes. Importantly, our analysis reveals that this measure provides unique information not accounted for by subject-specific factors such as age and duration of deafness. Conclusion: This approach utilizes an easily deployable resting-state functional brain imaging metric to predict speech understanding outcomes in implant recipients. The results indicate that the average clustering coefficient, both pre and post implantation, correlates with speech understanding outcomes.
Open AccessResting-state Functional Connectivity Predicts Cochlear-Implant Speech Outcomes
Background: Cochlear implants (CIs) have revolutionized hearing restoration for individuals with severe or profound hearing loss. However, a substantial and unexplained variability persists in CI outcomes, even when considering subject-specific factors such as age and the duration of deafness. In this study, we explore the utility of resting-state functional near-infrared spectroscopy (fNIRS) recordings to predict speech understanding outcomes before and after CI implantation. Our hypothesis revolves around resting-state functional connectivity (FC) as a reflection of brain plasticity post-hearing loss and implantation. Specifically, we hypothesized that the average clustering coefficient in resting FC networks can capture this variation among CI users. Methods: Twenty-two cochlear implant candidates participated in this study. Resting-state fNIRS data were collected pre-implantation and at one month, three months, and one year post-implantation. Speech understanding performance was assessed using CNC words in quiet and BKB sentences in noise one year post-implantation. Resting-state functional connectivity networks were constructed using regularized partial correlation, and the average clustering coefficient was measured in the signed weighted networks as a predictive measure for implantation outcomes. Results: Our findings demonstrate a significant correlation between the average clustering coefficient in resting-state functional networks and speech understanding outcomes. Importantly, our analysis reveals that this measure provides unique information not accounted for by subject-specific factors such as age and duration of deafness. Conclusion: This approach utilizes an easily deployable resting-state functional brain imaging metric to predict speech understanding outcomes in implant recipients. The results indicate that the average clustering coefficient, both pre and post implantation, correlates with speech understanding outcomes.