Abstract
Electron Beam Induced Current (EBIC) mapping of Ga2O3 Schottky diodes after soft breakdown reveal the presence of defects with bright contrast absent before the breakdown. The defects are of two types: smaller point-like defect features with weaker contrast and larger (about 1 m) defects with a very strong EBIC contrast. For both types of defects a prominent gain of the EBIC signal compared to the signal expected for theoretically estimated value based on the assumption of total collection of charge of electrons and holes generated by the probing beam was observed. For point-like defects the gain was on the order of 100, with the time of gain-build-up lower than 5 μs and the time of gain decay of 15 μs. For the “strong” defects the gain was very high, on the order of 104, with the gain build-up time also below 5 μs, while the gain decay time was slightly longer than for point-like defects (20-25 μs). The appearance of the defects in EBIC images correlates with the recently reported localized enhancement of the signal due to traps with levels close to 0.75 eV and 1 eV below the conduction band.
Funding Information
  • state task (075-00295-25-00)
  • Russian Science Foundation (25- 72-10020)

This publication has 18 references indexed in Scilit: