Biomechanical Evaluation of Sacral Load Redistribution Following Unilateral and Bilateral Sacroiliac Joint Disruption: A Three-Dimensional Finite Element Comparison of Three Fixation Strategies
Preprint
- 8 April 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background: Sacroiliac joint (SIJ) disruption alters posterior pelvic ring stability and may result in abnormal sacral stress redistribution. The biomechanical effects of different fixation strategies on sacral load transfer remain controversial. This study aimed to compare sacral stress patterns under unilateral and bilateral SIJ instability using three fixation techniques in a three-dimensional finite element model. Methods: A three-dimensional lumbosacral–pelvic finite element model was reconstructed from computed tomography data of a healthy adult and validated against previously published pelvic biomechanical data. SIJ instability was simulated by reducing the friction coefficient to represent ligamentous failure. Three fixation constructs were analyzed: anterior plate with posterior screw fixation, spinopelvic fixation, and hybrid fixation. A 750 N axial compressive load was applied to simulate static standing conditions; dynamic loading scenarios such as walking or sitting were not included. Peak sacral von Mises stress and stress amplification factors were calculated and compared with the intact model. Results: Anterior plate combined with posterior screw fixation produced the highest sacral stress amplification (SAF = 3.46 under unilateral instability; peak stress 265.40 MPa), exceeding three times the intact value, particularly under unilateral left instability (SAF = 3.46). Spinopelvic fixation significantly reduced peak sacral stress (125.66 MPa under bilateral instability; SAF = 1.64) but remained above physiological levels. Hybrid fixation demonstrated sacral stress values closest to the intact condition (81.64 MPa; SAF = 1.06), with minimal amplification and near-symmetrical load distribution. Conclusions: Fixation strategy significantly influences sacral load redistribution following SIJ disruption. Hybrid fixation most effectively restored near-physiological sacral stress patterns, whereas anterior plate with posterior screw fixation resulted in excessive stress concentration. Hybrid stabilization may provide a biomechanically balanced approach for unstable posterior pelvic injuries.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Implantation of S1AIS has priority as a sacroiliac joint fixation techniqueEuropean Spine Journal, 2024
- Patient-specific bone material modelling can improve the predicted biomechanical outcomes of sacral fracture fixation techniques: A comparative finite element studyInjury, 2023
- Finite element analysis of sacral‐alar‐iliac screw fixation for sacroiliac joint dislocationJournal of Orthopaedic Research, 2023
- Intraoperative CT-assisted sacroiliac screws fixation for the treatment of posterior pelvic ring injury: a comparative study with conventional intraoperative imagingScientific Reports, 2022
- Rescue Pelvic Fixation in a Patient with Sacral-2-Alar-Iliac and Triangular Sacroiliac Joint Fusion (Bedrock) InstrumentationWorld Neurosurgery, 2022
- Plate versus sacroiliac screw fixation for treating posterior pelvic ring fracture: a Systematic review and meta-analysisInjury, 2020
- Finite element analysis of load transition on sacroiliac joint during bipedal walkingScientific Reports, 2020
- Biomechanical evaluation of sacroiliac joint fixation with decorticationThe Spine Journal, 2018
- Biomechanical characterization of three iliac screw fixation techniques: A finite element studyJournal of Clinical Neuroscience, 2018
- Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical testsComputers in Biology and Medicine, 2017