Melih Canlidi̇nç
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Melih Canlidi̇nç has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Dayanç
KUTAHYA DUMLUPINAR UNIVERSITY, FACULTY OF ENGINEERING
3 shared publications - Bünyamin Arı
Department of Orthopedics and Traumatology, Faculty of Medicine, Kütahya Health Sciences University, Kütahya 43000, Türkiye
3 shared publications - Nafiz Yaşar
Kutahya Dumlupinar Universitesi
3 shared publications - Feridun Karakoç
Faculty of Engineering, Kutahya Dumlupınar University, Kutahya, Türkiye
2 shared publications - Mustafa Güleşen
Dumlupinar Universitesi
2 shared publications Feridun Karakoç
Department of Mechanical Engineering, Kutahya Dumlupınar University, Turkey
1 shared publication
Latest Publications
- Open Access
Effects of Lattice Architecture, Nominal Feature Size and Heat Treatment on the Tensile Behavior of L-PBF-Fabricated Inconel 718 Lattice Structures
Laser powder bed fusion (L-PBF)-fabricated Inconel 718 lattice structures offer considerable potential for lightweight load-bearing applications, but their mechanical integrity depends on architecture, geometric scale, manufacturing defects, and post-processing condition. This study examined the combined effects of Diamond, Gyroid, and Octet architectures, nominal feature sizes of 1.0, 1.25, and 1.5 mm, and four heat-treatment conditions on tensile behavior and fracture characteristics. The specimens were evaluated using explicit-dynamics finite element analysis, room-temperature quasi-static tensile testing, and SEM fractography. A feature-size-dependent reversal in architecture ranking was observed: Gyroid exhibited the highest mean apparent tensile strength among the 1.0 mm lattices across the investigated heat-treatment conditions, whereas Diamond exhibited the highest mean apparent tensile strength among the 1.5 mm lattices across the same conditions. HT-C shifted the tensile response toward higher apparent strength and lower apparent deformation capacity, whereas selected HT-B-treated specimens exhibited more ductile fracture morphologies. These findings show that architecture, nominal feature size, and post-processing condition must be considered jointly when designing L-PBF Inconel 718 lattice components within the investigated design range.
Open AccessEffects of Lattice Architecture, Nominal Feature Size and Heat Treatment on the Tensile Behavior of L-PBF-Fabricated Inconel 718 Lattice Structures
Laser powder bed fusion (L-PBF)-fabricated Inconel 718 lattice structures offer considerable potential for lightweight load-bearing applications, but their mechanical integrity depends on architecture, geometric scale, manufacturing defects, and post-processing condition. This study examined the combined effects of Diamond, Gyroid, and Octet architectures, nominal feature sizes of 1.0, 1.25, and 1.5 mm, and four heat-treatment conditions on tensile behavior and fracture characteristics. The specimens were evaluated using explicit-dynamics finite element analysis, room-temperature quasi-static tensile testing, and SEM fractography. A feature-size-dependent reversal in architecture ranking was observed: Gyroid exhibited the highest mean apparent tensile strength among the 1.0 mm lattices across the investigated heat-treatment conditions, whereas Diamond exhibited the highest mean apparent tensile strength among the 1.5 mm lattices across the same conditions. HT-C shifted the tensile response toward higher apparent strength and lower apparent deformation capacity, whereas selected HT-B-treated specimens exhibited more ductile fracture morphologies. These findings show that architecture, nominal feature size, and post-processing condition must be considered jointly when designing L-PBF Inconel 718 lattice components within the investigated design range.
- Open Access
Biomechanical Evaluation of Sacral Load Redistribution Following Unilateral and Bilateral Sacroiliac Joint Disruption: A Three-Dimensional Finite Element Comparison of Three Fixation Strategies
Sacroiliac joint (SIJ) disruption alters posterior pelvic ring stability and can produce abnormal sacral stress redistribution; the symmetry of sacral load transfer following different fixation strategies remains controversial. This study compared sacral stress patterns under unilateral and bilateral SIJ instability for three fixation constructs using a three-dimensional finite element (FE) model. A lumbosacral–pelvic FE model was reconstructed from computed tomography data of a healthy adult and validated against previously published pelvic biomechanical data. SIJ instability was simulated by reducing the friction coefficient to represent ligamentous failure. Three fixation constructs were analyzed: anterior plate combined with posterior screw fixation (Model 1), spinopelvic fixation (Model 2), and hybrid fixation (Model 3). A 750 N axial compressive load was applied to simulate static standing. Peak sacral von Mises stress, stress amplification factors (SAFs), and left–right asymmetry ratios were computed and compared with the intact reference. Model 1 produced the highest sacral stress amplification (SAF = 3.46 under unilateral instability; peak stress 265.40 MPa). Model 2 reduced peak sacral stress (125.66 MPa under bilateral instability; SAF = 1.64), but values remained above the intact-model baseline. Model 3 yielded sacral stress closest to the intact condition under bilateral instability (81.64 MPa; SAF = 1.06), with near-symmetric load distribution in the bilateral injury configuration. Fixation topology strongly influenced sacral load transfer: hybrid fixation (Model 3) produced sacral stress magnitudes closest to the intact model, particularly under bilateral instability, whereas spinopelvic fixation (Model 2) showed more consistent left–right symmetry under unilateral injury. No single construct was superior across all symmetry-related outcomes. Hybrid stabilization may provide a biomechanically balanced approach to highly unstable posterior pelvic ring injuries under the simulated static axial-loading conditions.
Open AccessBiomechanical Evaluation of Sacral Load Redistribution Following Unilateral and Bilateral Sacroiliac Joint Disruption: A Three-Dimensional Finite Element Comparison of Three Fixation Strategies
Sacroiliac joint (SIJ) disruption alters posterior pelvic ring stability and can produce abnormal sacral stress redistribution; the symmetry of sacral load transfer following different fixation strategies remains controversial. This study compared sacral stress patterns under unilateral and bilateral SIJ instability for three fixation constructs using a three-dimensional finite element (FE) model. A lumbosacral–pelvic FE model was reconstructed from computed tomography data of a healthy adult and validated against previously published pelvic biomechanical data. SIJ instability was simulated by reducing the friction coefficient to represent ligamentous failure. Three fixation constructs were analyzed: anterior plate combined with posterior screw fixation (Model 1), spinopelvic fixation (Model 2), and hybrid fixation (Model 3). A 750 N axial compressive load was applied to simulate static standing. Peak sacral von Mises stress, stress amplification factors (SAFs), and left–right asymmetry ratios were computed and compared with the intact reference. Model 1 produced the highest sacral stress amplification (SAF = 3.46 under unilateral instability; peak stress 265.40 MPa). Model 2 reduced peak sacral stress (125.66 MPa under bilateral instability; SAF = 1.64), but values remained above the intact-model baseline. Model 3 yielded sacral stress closest to the intact condition under bilateral instability (81.64 MPa; SAF = 1.06), with near-symmetric load distribution in the bilateral injury configuration. Fixation topology strongly influenced sacral load transfer: hybrid fixation (Model 3) produced sacral stress magnitudes closest to the intact model, particularly under bilateral instability, whereas spinopelvic fixation (Model 2) showed more consistent left–right symmetry under unilateral injury. No single construct was superior across all symmetry-related outcomes. Hybrid stabilization may provide a biomechanically balanced approach to highly unstable posterior pelvic ring injuries under the simulated static axial-loading conditions.
- Open Access
- 8 April 2026
- Published by MDPI AG in Preprints.org
Biomechanical Evaluation of Sacral Load Redistribution Following Unilateral and Bilateral Sacroiliac Joint Disruption: A Three-Dimensional Finite Element Comparison of Three Fixation Strategies
Background: Sacroiliac joint (SIJ) disruption alters posterior pelvic ring stability and may result in abnormal sacral stress redistribution. The biomechanical effects of different fixation strategies on sacral load transfer remain controversial. This study aimed to compare sacral stress patterns under unilateral and bilateral SIJ instability using three fixation techniques in a three-dimensional finite element model. Methods: A three-dimensional lumbosacral–pelvic finite element model was reconstructed from computed tomography data of a healthy adult and validated against previously published pelvic biomechanical data. SIJ instability was simulated by reducing the friction coefficient to represent ligamentous failure. Three fixation constructs were analyzed: anterior plate with posterior screw fixation, spinopelvic fixation, and hybrid fixation. A 750 N axial compressive load was applied to simulate static standing conditions; dynamic loading scenarios such as walking or sitting were not included. Peak sacral von Mises stress and stress amplification factors were calculated and compared with the intact model. Results: Anterior plate combined with posterior screw fixation produced the highest sacral stress amplification (SAF = 3.46 under unilateral instability; peak stress 265.40 MPa), exceeding three times the intact value, particularly under unilateral left instability (SAF = 3.46). Spinopelvic fixation significantly reduced peak sacral stress (125.66 MPa under bilateral instability; SAF = 1.64) but remained above physiological levels. Hybrid fixation demonstrated sacral stress values closest to the intact condition (81.64 MPa; SAF = 1.06), with minimal amplification and near-symmetrical load distribution. Conclusions: Fixation strategy significantly influences sacral load redistribution following SIJ disruption. Hybrid fixation most effectively restored near-physiological sacral stress patterns, whereas anterior plate with posterior screw fixation resulted in excessive stress concentration. Hybrid stabilization may provide a biomechanically balanced approach for unstable posterior pelvic injuries.
- 8 April 2026
- Published by MDPI AG in Preprints.org
Open AccessBiomechanical Evaluation of Sacral Load Redistribution Following Unilateral and Bilateral Sacroiliac Joint Disruption: A Three-Dimensional Finite Element Comparison of Three Fixation Strategies
Background: Sacroiliac joint (SIJ) disruption alters posterior pelvic ring stability and may result in abnormal sacral stress redistribution. The biomechanical effects of different fixation strategies on sacral load transfer remain controversial. This study aimed to compare sacral stress patterns under unilateral and bilateral SIJ instability using three fixation techniques in a three-dimensional finite element model. Methods: A three-dimensional lumbosacral–pelvic finite element model was reconstructed from computed tomography data of a healthy adult and validated against previously published pelvic biomechanical data. SIJ instability was simulated by reducing the friction coefficient to represent ligamentous failure. Three fixation constructs were analyzed: anterior plate with posterior screw fixation, spinopelvic fixation, and hybrid fixation. A 750 N axial compressive load was applied to simulate static standing conditions; dynamic loading scenarios such as walking or sitting were not included. Peak sacral von Mises stress and stress amplification factors were calculated and compared with the intact model. Results: Anterior plate combined with posterior screw fixation produced the highest sacral stress amplification (SAF = 3.46 under unilateral instability; peak stress 265.40 MPa), exceeding three times the intact value, particularly under unilateral left instability (SAF = 3.46). Spinopelvic fixation significantly reduced peak sacral stress (125.66 MPa under bilateral instability; SAF = 1.64) but remained above physiological levels. Hybrid fixation demonstrated sacral stress values closest to the intact condition (81.64 MPa; SAF = 1.06), with minimal amplification and near-symmetrical load distribution. Conclusions: Fixation strategy significantly influences sacral load redistribution following SIJ disruption. Hybrid fixation most effectively restored near-physiological sacral stress patterns, whereas anterior plate with posterior screw fixation resulted in excessive stress concentration. Hybrid stabilization may provide a biomechanically balanced approach for unstable posterior pelvic injuries.
- 30 December 2025
- Published by Manufacturing Technologies and Applications in İmalat Teknolojileri ve Uygulamaları
- Vol. 6 (3) , 318-326
Topology Optimization of an Aircraft Bracket with a Multi-Criteria Approach
In the aviation industry, lightweight design has long been central to structural efficiency. Reducing weight reduces fuel consumption and increases overall performance. Metal additive manufacturing has made it possible to produce lightweight components with complex geometries. However, the vibration behavior of parts manufactured with these methods also requires careful consideration. Maintaining or increasing the natural frequency is critical, especially for parts under dynamic loads, such as engine mounting brackets. Increasing the natural frequency reduces the risk of resonance and extends fatigue life. Topology optimization stands out as an effective design approach in this context. This method reduces weight and increases strength by optimizing material distribution under certain constraints. This study examines the topology optimization process of an aircraft engine bracket manufactured from Ti-6Al-4V material, performed using the SIMP method, and the vibration behavior of the optimized part. The main optimization goal in this process was to maintain and maximize the natural frequency, while criteria for volumetric/mass reduction were also applied by improving strength. Static and modal analysis results of the bracket obtained after optimization revealed a 32.5% volumetric/mass reduction for the optimized bracket compared to the baseline bracket, while von Mises stress values decreased by 12.2%. At natural frequency, the first mode of the optimized bracket increased by 5.11%, while the other modes increased by 8-15%. The results demonstrate that the design is successful in terms of both mass reduction and dynamic performance. The integration of topology optimization and additive manufacturing holds great potential for the development of lighter and more durable components in future aerospace structures.
- 30 December 2025
- Published by Manufacturing Technologies and Applications in İmalat Teknolojileri ve Uygulamaları
- Vol. 6 (3) , 318-326
Topology Optimization of an Aircraft Bracket with a Multi-Criteria Approach
In the aviation industry, lightweight design has long been central to structural efficiency. Reducing weight reduces fuel consumption and increases overall performance. Metal additive manufacturing has made it possible to produce lightweight components with complex geometries. However, the vibration behavior of parts manufactured with these methods also requires careful consideration. Maintaining or increasing the natural frequency is critical, especially for parts under dynamic loads, such as engine mounting brackets. Increasing the natural frequency reduces the risk of resonance and extends fatigue life. Topology optimization stands out as an effective design approach in this context. This method reduces weight and increases strength by optimizing material distribution under certain constraints. This study examines the topology optimization process of an aircraft engine bracket manufactured from Ti-6Al-4V material, performed using the SIMP method, and the vibration behavior of the optimized part. The main optimization goal in this process was to maintain and maximize the natural frequency, while criteria for volumetric/mass reduction were also applied by improving strength. Static and modal analysis results of the bracket obtained after optimization revealed a 32.5% volumetric/mass reduction for the optimized bracket compared to the baseline bracket, while von Mises stress values decreased by 12.2%. At natural frequency, the first mode of the optimized bracket increased by 5.11%, while the other modes increased by 8-15%. The results demonstrate that the design is successful in terms of both mass reduction and dynamic performance. The integration of topology optimization and additive manufacturing holds great potential for the development of lighter and more durable components in future aerospace structures.
- Open Access
- 23 September 2025
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 37 (1) , 180-189
In case effects of proximal fibular osteotomy and total knee arthroplasty on load distribution in the human knee: A comparative finite element study
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- 23 September 2025
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 37 (1) , 180-189
Open AccessIn case effects of proximal fibular osteotomy and total knee arthroplasty on load distribution in the human knee: A comparative finite element study
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- Open Access
- 2 June 2025
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
The Effects of Lifting Techniques on the L5-S1 Joint: Lifting Different Loads from Ground Level
Manual material lifting is a common activity in daily life and industrial work environments, placing significant stress on the L5/S1 joint in the lower back. This study aims to compare the biomechanical impacts of squat and stoop lifting techniques on the L5/S1 joint to assess load distribution and potential injury risks in manual handling tasks. In contrast to previous studies using boxes with handles, our experiments involve lifting cargo boxes from the bottom without handles, providing a more realistic simulation for cargo handling workers. Five healthy male participants performed squat and stoop lifts with weights of 4, 8, 12, and 16 kg. Markerless motion capture was conducted using the Kinect v2 sensor, and kinematic and kinetic data were analyzed with the OpenSim biomechanical modeling software. Results indicated that squat lifting reduced compression forces by approximately 9% and shear forces by 25% at the L5/S1 joint compared to stoop lifting for heavier loads. These findings align with previous literature, demonstrating that squat lifting may better distribute loads across the lumbar spine, suggesting it as a potentially safer method for handling heavier loads.
- 2 June 2025
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
Open AccessThe Effects of Lifting Techniques on the L5-S1 Joint: Lifting Different Loads from Ground Level
Manual material lifting is a common activity in daily life and industrial work environments, placing significant stress on the L5/S1 joint in the lower back. This study aims to compare the biomechanical impacts of squat and stoop lifting techniques on the L5/S1 joint to assess load distribution and potential injury risks in manual handling tasks. In contrast to previous studies using boxes with handles, our experiments involve lifting cargo boxes from the bottom without handles, providing a more realistic simulation for cargo handling workers. Five healthy male participants performed squat and stoop lifts with weights of 4, 8, 12, and 16 kg. Markerless motion capture was conducted using the Kinect v2 sensor, and kinematic and kinetic data were analyzed with the OpenSim biomechanical modeling software. Results indicated that squat lifting reduced compression forces by approximately 9% and shear forces by 25% at the L5/S1 joint compared to stoop lifting for heavier loads. These findings align with previous literature, demonstrating that squat lifting may better distribute loads across the lumbar spine, suggesting it as a potentially safer method for handling heavier loads.
- Open Access
- 31 December 2023
- Published by Kirklareli Universitesi Muhendislik ve Fen Bilimleri Dergisi in Kırklareli Üniversitesi Mühendislik ve Fen Bilimleri Dergisi
- Vol. 9 (2) , 552-565
Topoloji Optimizasyonu ile Metal Eklemeli İmalat Yönteminin Endüstriyel Uygulamaları
Metal eklemeli imalat, geleneksel üretim yöntemleriyle mümkün olmayan karmaşık metal yapıları üretme kapasitesiyle yenilikçi üretim süreçlerinde önemli bir rol oynamaktadır. Topoloji optimizasyonu ise, belirlenen tasarım alanlarında hedeflenen parametreleri en uygun şekilde dağıtarak malzeme verimliliğini artırır. Bu çalışma, metal eklemeli imalat ve topoloji optimizasyonunun endüstriyel uygulamalarını derinlemesine inceleyerek, bu teknolojilerin özellikle havacılık, medikal ve otomotiv sektörlerinde üretilebilirlik, işlevsellik ve tasarım özgürlüğü açısından önemli avantajlar sunduğunu göstermektedir. Havacılık sektöründe, uçak parçalarının hafifletilmesi ve yapısal bütünlüğün artırılmasında Metal eklemeli imalat ve topoloji optimizasyonunun birleşimi kritik öneme sahiptir. Medikal alanda, özelleştirilmiş implantlar ve kemik yapıları için bu yöntemlerin entegrasyonu, hastalara özel çözümler sunarak tedavi süreçlerini iyileştirmektedir. Otomotiv endüstrisinde ise, bu teknolojiler araçların performansını artırırken ağırlığını azaltarak enerji verimliliğini yükseltiyor. Bu çalışma metal eklemeli imalat ve topoloji optimizasyonunun endüstriyel uygulamalardaki zorlukları ve sınırlamaları da ele almıştır. Ayrıca bu teknolojilerin gelecekteki gelişim yönlerini ve potansiyellerini detaylı bir şekilde ortaya koyarak, endüstriyel tasarımda yenilikçi yaklaşımların önünü açması amaçlanmıştır.
- 31 December 2023
- Published by Kirklareli Universitesi Muhendislik ve Fen Bilimleri Dergisi in Kırklareli Üniversitesi Mühendislik ve Fen Bilimleri Dergisi
- Vol. 9 (2) , 552-565
Open AccessTopoloji Optimizasyonu ile Metal Eklemeli İmalat Yönteminin Endüstriyel Uygulamaları
Metal eklemeli imalat, geleneksel üretim yöntemleriyle mümkün olmayan karmaşık metal yapıları üretme kapasitesiyle yenilikçi üretim süreçlerinde önemli bir rol oynamaktadır. Topoloji optimizasyonu ise, belirlenen tasarım alanlarında hedeflenen parametreleri en uygun şekilde dağıtarak malzeme verimliliğini artırır. Bu çalışma, metal eklemeli imalat ve topoloji optimizasyonunun endüstriyel uygulamalarını derinlemesine inceleyerek, bu teknolojilerin özellikle havacılık, medikal ve otomotiv sektörlerinde üretilebilirlik, işlevsellik ve tasarım özgürlüğü açısından önemli avantajlar sunduğunu göstermektedir. Havacılık sektöründe, uçak parçalarının hafifletilmesi ve yapısal bütünlüğün artırılmasında Metal eklemeli imalat ve topoloji optimizasyonunun birleşimi kritik öneme sahiptir. Medikal alanda, özelleştirilmiş implantlar ve kemik yapıları için bu yöntemlerin entegrasyonu, hastalara özel çözümler sunarak tedavi süreçlerini iyileştirmektedir. Otomotiv endüstrisinde ise, bu teknolojiler araçların performansını artırırken ağırlığını azaltarak enerji verimliliğini yükseltiyor. Bu çalışma metal eklemeli imalat ve topoloji optimizasyonunun endüstriyel uygulamalardaki zorlukları ve sınırlamaları da ele almıştır. Ayrıca bu teknolojilerin gelecekteki gelişim yönlerini ve potansiyellerini detaylı bir şekilde ortaya koyarak, endüstriyel tasarımda yenilikçi yaklaşımların önünü açması amaçlanmıştır.
- Open Access
- 31 December 2023
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 7 (3) , 478-484
AN INNOVATIVE METHODOLOGY TO DESIGN GYROID HEAT EXCHANGERS FOR METAL ADDITIVE MANUFACTURING
This study demonstrates an innovative approach to the automatic design of compact gyroid heat exchangers using the advanced engineering software nTopology, which is based on implicit modeling technology. The aim is to provide a modern enhancement to traditional 'Shell and Tube' type heat exchangers. Utilizing functions in implicit modeling and parametric design features, complex internal gyroid structures can be used as an alternative heat transfer interface in 'Shell and Tube' type heat exchangers. The most striking aspect of the methodology is its ability to fully automate the design process. By consolidating specific parameters into a single function block and entering scalar values, a fast and flexible workflow is activated, automatically generating the final geometry. Gyroid structures with high thermal performance and fluid dynamics are automatically adapted for various volumes and geometries. These structures can improve the overall efficiency of heat exchangers and offer significant advantages, especially in specialized application areas such as aerospace and space industries. In the design and sizing process of the gyroid heat exchanger, if manufacturing is planned, it is necessary to pay attention to the design principles for metal additive manufacturing. In conclusion, this study demonstrates that the advanced engineering software known as nTopology can create a synergistic effect in the rapid and easy design of gyroid heat exchangers and in establishing the automation of the design process.
- 31 December 2023
- Published by International Journal of 3D Printing Technologies and Digital Industry in International Journal of 3D Printing Technologies and Digital Industry
- Vol. 7 (3) , 478-484
Open AccessAN INNOVATIVE METHODOLOGY TO DESIGN GYROID HEAT EXCHANGERS FOR METAL ADDITIVE MANUFACTURING
This study demonstrates an innovative approach to the automatic design of compact gyroid heat exchangers using the advanced engineering software nTopology, which is based on implicit modeling technology. The aim is to provide a modern enhancement to traditional 'Shell and Tube' type heat exchangers. Utilizing functions in implicit modeling and parametric design features, complex internal gyroid structures can be used as an alternative heat transfer interface in 'Shell and Tube' type heat exchangers. The most striking aspect of the methodology is its ability to fully automate the design process. By consolidating specific parameters into a single function block and entering scalar values, a fast and flexible workflow is activated, automatically generating the final geometry. Gyroid structures with high thermal performance and fluid dynamics are automatically adapted for various volumes and geometries. These structures can improve the overall efficiency of heat exchangers and offer significant advantages, especially in specialized application areas such as aerospace and space industries. In the design and sizing process of the gyroid heat exchanger, if manufacturing is planned, it is necessary to pay attention to the design principles for metal additive manufacturing. In conclusion, this study demonstrates that the advanced engineering software known as nTopology can create a synergistic effect in the rapid and easy design of gyroid heat exchangers and in establishing the automation of the design process.
- Open Access
- 5 October 2023
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 47
Improving personalized medical implant design: An innovative and automated method leveraging implicit modeling
- 5 October 2023
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 47
Open AccessImproving personalized medical implant design: An innovative and automated method leveraging implicit modeling
- Open Access
- 26 June 2023
- Published by Journal of Materials and Mechatronics: A in Journal of Materials and Mechatronics: A
- Vol. 4 (1) , 1-10
Investigation of the Effect of Box Size on L5/S1 Joint in Manual Lifting
Günlük hayatta ve çalışma koşullarında elle nesne kaldırma eylemi yaygın olarak uygulanmaktadır. Elle nesne kaldırma eylemi insan vücut eklemlerinde çeşitli yüklenmeler oluşturmaktadır. Araştırmalara göre özellikle bel bölgesi kaldırma hareketinden en çok etkilenen bölgedir ve kaldırma hareketi sırasında bel bölgesindeki omurlar incelendiğinde, moment kolunun en yüksek olduğu L5/S1 eklemindeki yüklenme en yüksektir. Elle nesne kaldırma hareketinde L5/S1 eklemine etkisinin incelendiği araştırmalarda, kaldırma hareketi nesnenin iki yanındaki nesne tabanından belirli yükseklikteki tutamaçlardan tutularak gerçekleştirilmektedir. Bu çalışmada katılımcılar elle kaldırma hareketini önceki çalışmalardan farklı olarak kutuların altından kavrayarak gerçekleştirmişlerdir. Deneylerde katılımcıların 16 kg kütleli ve 3 farklı ebattaki kutuların 2 farklı kaldırma tekniği olan çömelerek ve eğilerek kaldırma hareketi sırasında L5/S1 ekleminde oluşan yüklerin değerlendirilmesi yapılmıştır. Kaldırma hareketleri Microsoft Kinect v2 kamerayla kaydedilmiştir. Kutuların elle kaldırma hareketinin L5/S1 eklemine etkisini incelemek amacıyla OpenSim biyomekanik model yazılımı kullanılmıştır. Kullanılan biyomekanik modele aktarılan insan vücut eklemleri konum verilerinin ters kinematik analiziyle eklem açıları, ters dinamik analiziyle ise eklem torkları elde edilmiştir. Daha sonra eklem reaksiyon analizi yapılarak L5/S1 eklemine binen yükler değerlendirilmiştir. Deneyler sonucunda küçük, orta ve büyük kutularda çömelerek kaldırma hareketinde L5/S1 eklemine etkiyen kompresyon kuvvetleri eğilerek kaldırmaya göre %8.8-9.1-9.6 oranında artış, eğilerek kaldırma hareketinde L5/S1 eklemine etkiyen kesme kuvvetleri çömelerek kaldırmaya göre %24.5-25.7-27.4 oranında artış göstermiştir.
- 26 June 2023
- Published by Journal of Materials and Mechatronics: A in Journal of Materials and Mechatronics: A
- Vol. 4 (1) , 1-10
Open AccessInvestigation of the Effect of Box Size on L5/S1 Joint in Manual Lifting
Günlük hayatta ve çalışma koşullarında elle nesne kaldırma eylemi yaygın olarak uygulanmaktadır. Elle nesne kaldırma eylemi insan vücut eklemlerinde çeşitli yüklenmeler oluşturmaktadır. Araştırmalara göre özellikle bel bölgesi kaldırma hareketinden en çok etkilenen bölgedir ve kaldırma hareketi sırasında bel bölgesindeki omurlar incelendiğinde, moment kolunun en yüksek olduğu L5/S1 eklemindeki yüklenme en yüksektir. Elle nesne kaldırma hareketinde L5/S1 eklemine etkisinin incelendiği araştırmalarda, kaldırma hareketi nesnenin iki yanındaki nesne tabanından belirli yükseklikteki tutamaçlardan tutularak gerçekleştirilmektedir. Bu çalışmada katılımcılar elle kaldırma hareketini önceki çalışmalardan farklı olarak kutuların altından kavrayarak gerçekleştirmişlerdir. Deneylerde katılımcıların 16 kg kütleli ve 3 farklı ebattaki kutuların 2 farklı kaldırma tekniği olan çömelerek ve eğilerek kaldırma hareketi sırasında L5/S1 ekleminde oluşan yüklerin değerlendirilmesi yapılmıştır. Kaldırma hareketleri Microsoft Kinect v2 kamerayla kaydedilmiştir. Kutuların elle kaldırma hareketinin L5/S1 eklemine etkisini incelemek amacıyla OpenSim biyomekanik model yazılımı kullanılmıştır. Kullanılan biyomekanik modele aktarılan insan vücut eklemleri konum verilerinin ters kinematik analiziyle eklem açıları, ters dinamik analiziyle ise eklem torkları elde edilmiştir. Daha sonra eklem reaksiyon analizi yapılarak L5/S1 eklemine binen yükler değerlendirilmiştir. Deneyler sonucunda küçük, orta ve büyük kutularda çömelerek kaldırma hareketinde L5/S1 eklemine etkiyen kompresyon kuvvetleri eğilerek kaldırmaya göre %8.8-9.1-9.6 oranında artış, eğilerek kaldırma hareketinde L5/S1 eklemine etkiyen kesme kuvvetleri çömelerek kaldırmaya göre %24.5-25.7-27.4 oranında artış göstermiştir.