Ablation of articular cartilage with an erbium:YAG laser: An ex vivo study using porcine models under real conditions—ablation measurement and histological examination
Authors:
- Jörg MeisterJMJörg Meister
- Norbert GutknechtNGNorbert Gutknecht
- 2 October 2009
- journal article
- case report
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 41 (9) , 674-685
Abstract
Background and Objectives: The use of an erbium:YAG laser in arthroscopic surgery has the advantage of a precise treatment of soft tissue. Due to the high absorption in water, the laser energy is perfectly matched to smoothing the hydrous, fibrillated articular cartilage surface. In minimal invasive surgery, the workspace is filled with aqueous liquids for enlargement. This appears contrary to the absorption characteristics of erbium:YAG laser radiation in water. The purpose of this study was to evaluate the ablated volume per pulse of cartilage lesions and the potential side effects including thermal damage and tissue necrosis.Study Design/Materials and Methods: Twenty‐four osteochondral specimens of porcine knee joints were irradiated with an Er:YAG laser completely submerged in water, with distances to the cartilage surface of 1, 3 and 5 mm and pulse durations of 75 and 100 microseconds. To keep a constant peak power of approximately 6 kW, pulse energies of 450 and 580 mJ were used at a pulse repetition rate of 15 Hz. After a histological preparation, ablated volumes, depths, and widths of the cuts were investigated. Additionally, laser protocols were correlated with different markers of cartilage tissue damage and apoptosis.Results: Ablation could be observed for every measurement. The influence of the distance showed a statistical significance (P < 0.001) for the volume, depth, and width of the cuts. For the pulse duration, statistical significance (P < 0.001) was found only for the volume and the depth. We observed no loss of proteoglycan or collagen type II. The total cell number, cell morphology, and number of apoptotic cells in an area close to the cutting edge and in a corresponding unaffected area of the same specimens revealed no differences regardless of the applied protocol.Conclusion: The use of an Er:YAG laser demonstrates the successful application in liquid environments for cartilage removal without any damage of the surrounding tissue. Lasers Surg. Med. 41:674–685, 2009.Keywords
Funding Information
- RWTH Aachen University (AZ 23/03)
This publication has 66 references indexed in Scilit:
- Mid-IR laser ablation of articular and fibro-cartilage:A wavelength dependence study of thermal injury and crater morphologyLasers in Surgery and Medicine, 2006
- Influence of the water content in dental enamel and dentin on ablation with erbium YAG and erbium YSGG lasersJournal of Biomedical Optics, 2006
- Free electron laser ablation of articular and fibro-cartilage at 2.79, 2.9, 6.1, and 6.45 ?m: Mass removal studiesLasers in Surgery and Medicine, 2005
- Laser cartilage reshaping in an in vivo rabbit model using a 1.54 μm Er:Glass laserLasers in Surgery and Medicine, 2004
- Rate process analysis of thermal damage in cartilagePhysics in Medicine & Biology, 2002
- Wavelength-scalable hollow optical fibres with large photonic bandgaps for CO2 laser transmissionNature, 2002
- In vitro model for the study of necrosis and apoptosis in native cartilageThe Journal of Pathology, 2002
- ARTHROSCOPIC TREATMENT OF THE DEGENERATIVE KNEE IN OLDER ATHLETESClinics in Sports Medicine, 1997
- Dynamics of laser-induced channel formation in water and influence of pulse duration on the ablation of biotissue under water with pulsed erbium-laser radiationApplied Physics B, 1994
- Experimentelle Ergebnisse der Knorpelabrasio mit einem Excimer-Laser. Histologische und elektronenmikroskopische UntersuchungenZeitschrift für Orthopädie und ihre Grenzgebiete, 1989