Abstract
The current study proposed and evaluated “residual squeeze and excitation attention gate” (rSEAG), a novel network that can improve image quality by reducing distortion attributed to artifacts. This method was established by modifying the Cycle Generative Adversarial Network (cycleGAN)-based generator network using projection data for pre-reconstruction processing in digital breast tomosynthesis. Residual squeeze and excitation were installed in the bridge of the generator network, and the attention gate was installed in the skip connection between the encoder and decoder. Based on the radiation dose index (exposure index and division index) incident on the detector, the cases approved by the ethics committee and used for the study were classified as reference (675 projection images) and object (675 projection images). For the cases, unsupervised data containing a mixture of cases with and without masses were used. The cases were trained using cycleGAN with rSEAG and the conventional networks (ResUNet and U-Net). For testing, predictive processing was performed on cases (60 projection images) that were not used for learning. Images were generated using filtered backprojection reconstruction (kernel: Ramachandran and Lakshminarayanan) from projection data for testing data and without pre-reconstruction processing data (evaluation: in-focus plane). The distortion was evaluated using perception-based image quality evaluation (PIQE) analysis, texture analysis (feature: “Homogeneity” and “Contrast”), and a statistical model with a Gumbel distribution. PIQE has a low rSEAG value. Texture analysis showed that rSEAG and a network without cycleGAN were similar in terms of the “Contrast” feature. In dense breasts, ResUNet had the lowest “Contrast” feature and U-Net had differences between cases. The maximal variations in the Gumbel plot, rSEAG reduced the high-frequency ripple artifacts. In this study, rSEAG could improve distortion and reduce ripple artifacts.Keywords
This publication has 45 references indexed in Scilit:
- Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI‐guided radiation therapyMedical Physics, 2023
- A lightweight multi-modality medical image semantic segmentation network base on the novel UNeXt and Wave-MLPComputerized Medical Imaging and Graphics, 2023
- Visual and quantitative evaluation of microcalcifications in mammograms with deep learning-based super-resolutionEuropean Journal of Radiology, 2022
- A Data Set and Deep Learning Algorithm for the Detection of Masses and Architectural Distortions in Digital Breast Tomosynthesis ImagesJAMA Network Open, 2021
- Attention gated networks: Learning to leverage salient regions in medical imagesMedical Image Analysis, 2019
- Development of a novel algorithm for metal artifact reduction in digital tomosynthesis using projection-based dual-energy material decomposition for arthroplasty: A phantom studyPhysica Medica, 2018
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D imagesEuropean Radiology, 2010
- Digital breast tomosynthesis versus digital mammography: a clinical performance studyEuropean Radiology, 2009
- Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose indexEuropean Radiology, 2001