YKYukio Koibuchi

Yukio Koibuchi

*This is an algorithmically generated author record based on publicly available information.

Yukio Koibuchi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pre-Reconstruction Processing with the Cycle-Consist Generative Adversarial Network Combined with Attention Gate to Improve Image Quality in Digital Breast Tomosynthesis

    by Tsutomu Gomi, Kotomi Ishihara, Satoko Yamada, Yukio Koibuchi

    The current study proposed and evaluated “residual squeeze and excitation attention gate” (rSEAG), a novel network that can improve image quality by reducing distortion attributed to artifacts. This method was established by modifying the Cycle Generative Adversarial Network (cycleGAN)-based generator network using projection data for pre-reconstruction processing in digital breast tomosynthesis. Residual squeeze and excitation were installed in the bridge of the generator network, and the attention gate was installed in the skip connection between the encoder and decoder. Based on the radiation dose index (exposure index and division index) incident on the detector, the cases approved by the ethics committee and used for the study were classified as reference (675 projection images) and object (675 projection images). For the cases, unsupervised data containing a mixture of cases with and without masses were used. The cases were trained using cycleGAN with rSEAG and the conventional networks (ResUNet and U-Net). For testing, predictive processing was performed on cases (60 projection images) that were not used for learning. Images were generated using filtered backprojection reconstruction (kernel: Ramachandran and Lakshminarayanan) from projection data for testing data and without pre-reconstruction processing data (evaluation: in-focus plane). The distortion was evaluated using perception-based image quality evaluation (PIQE) analysis, texture analysis (feature: “Homogeneity” and “Contrast”), and a statistical model with a Gumbel distribution. PIQE has a low rSEAG value. Texture analysis showed that rSEAG and a network without cycleGAN were similar in terms of the “Contrast” feature. In dense breasts, ResUNet had the lowest “Contrast” feature and U-Net had differences between cases. The maximal variations in the Gumbel plot, rSEAG reduced the high-frequency ripple artifacts. In this study, rSEAG could improve distortion and reduce ripple artifacts.


  • Open Access

    Evaluation of a Generative Adversarial Network to Improve Image Quality and Reduce Radiation-Dose during Digital Breast Tomosynthesis

    by Tsutomu Gomi, Yukie Kijima, Takayuki Kobayashi, Yukio Koibuchi

    In this study, we evaluated the improvement of image quality in digital breast tomosynthesis under low-radiation dose conditions of pre-reconstruction processing using conditional generative adversarial networks [cGAN (pix2pix)]. Pix2pix pre-reconstruction processing with filtered back projection (FBP) was compared with and without multiscale bilateral filtering (MSBF) during pre-reconstruction processing. Noise reduction and preserve contrast rates were compared using full width at half-maximum (FWHM), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) in the in-focus plane using a BR3D phantom at various radiation doses [reference-dose (automatic exposure control reference dose: AECrd), 50% and 75% reduction of AECrd] and phantom thicknesses (40 mm, 50 mm, and 60 mm). The overall performance of pix2pix pre-reconstruction processing was effective in terms of FWHM, PSNR, and SSIM. At ~50% radiation-dose reduction, FWHM yielded good results independently of the microcalcification size used in the BR3D phantom, and good noise reduction and preserved contrast. PSNR results showed that pix2pix pre-reconstruction processing represented the minimum in the error with reference FBP images at an approximately 50% reduction in radiation-dose. SSIM analysis indicated that pix2pix pre-reconstruction processing yielded superior similarity when compared with and without MSBF pre-reconstruction processing at ~50% radiation-dose reduction, with features most similar to the reference FBP images. Thus, pix2pix pre-reconstruction processing is promising for reducing noise with preserve contrast and radiation-dose reduction in clinical practice.