Experimental investigation of the effective point of measurement for plane‐parallel chambers used in electron beam dosimetry
Authors:
Open Access
- 12 June 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (7) , e14059
Abstract
In this study, the effective point of measurement (EPOM) for plane‐parallel ionization chambers in clinical high‐energy electron beams was determined experimentally. Previous studies have reported that the EPOM of plane‐parallel chambers is shifted several tens of millimeters downstream from the inner surface of the entrance window to the cavity. These findings were based on the Monte Carlo (MC) simulation, and few experimental studies have been performed. Thus, additional experimental validations of the reported EPOMs were required. In this study, we investigated the EPOMs of three plane‐parallel chambers (NACP‐02, Roos and Advanced Markus) for clinical electron beams. The EPOMs were determined by comparing the measured percentage depth‐dose (PDD) of the plane‐parallel chambers and the PDD obtained using the microDiamond detector. The optimal shift to the EPOM was energy‐dependent. The determined EPOM showed no chamber‐to‐chamber variation, thereby allowing the use of a single value. The mean optimal shifts were 0.104 ± 0.011, 0.040 ± 0.012, and 0.012 ± 0.009 cm for NACP‐02, Roos, and Advanced Markus, respectively. These values are valid in the R50 range from 2.40 to 8.82 cm, which correspond to 6–22 MeV. Roos and Advanced Markus exhibited similar results to those of the previous studies, but NACP‐02 showed a larger shift. This is probably due to the uncertainty of the entrance window of NACP‐02. Therefore, it is necessary to carefully consider where the optimal EPOM is located when using this chamber.Keywords
This publication has 24 references indexed in Scilit:
- Effective point of measurement for parallel plate and cylindrical ion chambers in megavoltage electron beamsZeitschrift für Medizinische Physik, 2014
- Beam quality corrections for parallel-plate ion chambers in electron reference dosimetryPhysics in Medicine & Biology, 2012
- Experimental determination of the effective point of measurement for various detectors used in photon and electron beam dosimetryPhysics in Medicine & Biology, 2011
- On the wall perturbation correction for a parallel‐plate NACP‐02 chamber in clinical electron beamsMedical Physics, 2011
- Extraction of depth‐dependent perturbation factors for parallel‐plate chambers in electron beams using a plastic scintillation detectorMedical Physics, 2010
- Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulationMedical Physics, 2009
- Positioning of a plane-parallel ionization chamber in clinical electron beams and the impact on perturbation factorsPhysics in Medicine & Biology, 2009
- Validation of a Monte Carlo model of a NACP-02 plane-parallel ionization chamber model using electron backscatter experimentsPhysics in Medicine & Biology, 2008
- Determination of the recombination correction factorkSfor some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beamsPhysics in Medicine & Biology, 2006
- Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water; Technical Reports Series No. 398,Health Physics, 2001