Impact of errors in recorded compressed breast thickness measurements on volumetric density classification using volpara v1.5.0 software
- 16 May 2016
- journal article
- quantitative imaging-and-image-processing
- Published by Wiley in Medical Physics
- Vol. 43 (6Part1) , 2870-2876
Abstract
Purpose: Mammographic density has been demonstrated to predict breast cancer risk. It has been proposed that it could be used for stratifying screening pathways and recommending additional imaging. Volumetric density tools use the recorded compressed breast thickness (CBT) of the breast measured at the x‐ray unit in their calculation; however, the accuracy of the recorded thickness can vary. The aim of this study was to investigate whether inaccuracies in recorded CBT impact upon volumetric density classification and to examine whether the current quality control (QC) standard is sufficient for assessing mammographic density.Methods: Raw data from 52 digital screening mammograms were included in the study. For each image, the clinically recorded CBT was artificially increased and decreased in increments of 1 mm to simulate measurement error, until ±15% from the recorded CBT was reached. New images were created for each 1 mm step in thickness resulting in a total of 974 images which then had volpara density grade (VDG) and volumetric density percentage assigned.Results: A change in VDG was observed in 38.5% (n = 20) of mammograms when applying ±15% error to the recorded CBT and 11.5% (n = 6) was within the QC standard prescribed error of ±5 mm.Conclusions: The current QC standard of ±5 mm error in recorded CBT creates the potential for error in mammographic density measurement. This may lead to inaccurate classification of mammographic density. The current QC standard for assessing mammographic density should be reconsidered.Keywords
This publication has 37 references indexed in Scilit:
- AutoDensity: an automated method to measure mammographic breast density that predicts breast cancer risk and screening outcomesBreast Cancer Research, 2013
- Outcomes of Screening Mammography by Frequency, Breast Density, and Postmenopausal Hormone TherapyJAMA Internal Medicine, 2013
- Screening Outcomes in Older US Women Undergoing Multiple Mammograms in Community Practice: Does Interval, Age, or Comorbidity Score Affect Tumor Characteristics or False Positive Rates?JNCI: Journal of the National Cancer Institute, 2013
- Clinical Digital Breast Tomosynthesis System: Dosimetric CharacterizationRadiology, 2012
- The readout thickness versus the measured thickness for a range of screen film mammography and full-field digital mammography unitsMedical Physics, 2011
- Breast Tissue Composition and Susceptibility to Breast CancerJNCI: Journal of the National Cancer Institute, 2010
- Screen-Film Mammographic Density and Breast Cancer Risk: A Comparison of the Volumetric Standard Mammogram Form and the Interactive Threshold Measurement MethodsCancer Epidemiology, Biomarkers & Prevention, 2010
- The myth of the 50‐50 breastMedical Physics, 2009
- Combined Screening With Ultrasound and Mammography vs Mammography Alone in Women at Elevated Risk of Breast CancerJAMA, 2008
- Mammographic Density and the Risk and Detection of Breast CancerThe New England journal of medicine, 2007