JKJudith Kelly

Judith Kelly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Judith Kelly has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Supplementary Projections

    by Judith Kelly, Hannah Kearsley, Lyndsay A. Kinnear, Sheetal Ruparelia


  • The impact of simulated motion blur on lesion detection performance in full-field digital mammography

    by Ahmed K Abdullah, Judith Kelly, John D Thompson, Claire E Mercer, Rob Aspin, Peter Hogg

    Objective: Motion blur is a known phenomenon in full-field digital mammography, but the impact on lesion detection is unknown. This is the first study to investigate detection performance with varying magnitudes of simulated motion blur. Methods: 7 observers (15 ± 5 years' reporting experience) evaluated 248 cases (62 containing malignant masses, 62 containing malignant microcalcifications and 124 normal cases) for 3 conditions: no blurring (0 mm) and 2 magnitudes of simulated blurring (0.7 and 1.5 mm). Abnormal cases were biopsy proven. Mathematical simulation was used to provide a pixel shift in order to simulate motion blur. A free-response observer study was conducted to compare lesion detection performance for the three conditions. The equally weighted jackknife alternative free-response receiver operating characteristic was used as the figure of merit. Test alpha was set at 0.05 to control probability of Type I error. Results: The equally weighted jackknife alternative free-response receiver operating characteristic analysis found a statistically significant difference in lesion detection performance for both masses [F(2,22) = 6.01, p = 0.0084] and microcalcifications [F(2,49) = 23.14, p < 0.0001]. The figures of merit reduced as the magnitude of simulated blurring increased. Statistical differences were found between some of the pairs investigated for the detection of masses (0.0 vs 0.7 and 0.0 vs 1.5 mm) and all pairs for microcalcifications (0.0 vs 0.7, 0.0 vs 1.5 and 0.7 vs 1.5 mm). No difference was detected between 0.7 and 1.5 mm for masses. Conclusion: The mathematical simulation of motion blur caused a statistically significant reduction in lesion detection performance. These false-negative decisions could have implications for clinical practice. Advances in knowledge: This research demonstrates for the first time that motion blur has a negative and statistically significant impact on lesion detection performance in digital mammography.


  • Blurred digital mammography images: an analysis of technical recall and observer detection performance

    by Wang Kei Ma, Rita Borgen, Judith Kelly, Sara Millington, Beverley Hilton, Rob Aspin, Carla Lança, Peter Hogg

    Objective: Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. Methods: 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ 2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. Results: The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ 2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. Conclusion: According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring.


  • Impact of errors in recorded compressed breast thickness measurements on volumetric density classification using volpara v1.5.0 software

    by Gunvor Gipling Waade, Ralph Highnam, Ingrid H. R. Hauge, Mark F. McEntee, Solveig Hofvind, Erika Denton, Judith Kelly, Jasmine J. Sarwar, Peter Hogg

    Purpose: Mammographic density has been demonstrated to predict breast cancer risk. It has been proposed that it could be used for stratifying screening pathways and recommending additional imaging. Volumetric density tools use the recorded compressed breast thickness (CBT) of the breast measured at the x‐ray unit in their calculation; however, the accuracy of the recorded thickness can vary. The aim of this study was to investigate whether inaccuracies in recorded CBT impact upon volumetric density classification and to examine whether the current quality control (QC) standard is sufficient for assessing mammographic density.Methods: Raw data from 52 digital screening mammograms were included in the study. For each image, the clinically recorded CBT was artificially increased and decreased in increments of 1 mm to simulate measurement error, until ±15% from the recorded CBT was reached. New images were created for each 1 mm step in thickness resulting in a total of 974 images which then had volpara density grade (VDG) and volumetric density percentage assigned.Results: A change in VDG was observed in 38.5% (n = 20) of mammograms when applying ±15% error to the recorded CBT and 11.5% (n = 6) was within the QC standard prescribed error of ±5 mm.Conclusions: The current QC standard of ±5 mm error in recorded CBT creates the potential for error in mammographic density measurement. This may lead to inaccurate classification of mammographic density. The current QC standard for assessing mammographic density should be reconsidered.


  • What is the minimum amount of simulated breast movement required for visual detection of blurring? An exploratory investigation

    by W K Ma, R Aspin, J Kelly, S Millington, P Hogg

    Objective:Image blurring in mammography can cause significant image degradation and interpretational problems. A potential source is due to paddle movement during image formation. Paddle movement has been shown to be as much as 1.5 mm. No study has yet been performed to determine how much motion would be noticeable visually. The aim of this study is to determine the minimum amount of simulated breast movement at which blurring can be detected visually.Methods:25 artefact-free mammogram images were selected. Mathematical simulation software was created to mimic the effect of blurring produced by breast movement during exposure. Motion simulation was imposed to 15 levels, from 0.1 to 1.5 mm stepping through 0.1 mm increments. 15 degraded images and 1 without blurring were de-identified, randomized and assessed on a blinded basis by two clinical experts to determine the presence or absence of blurring. Statistical testing was carried out to determine the consistency between the two observers.Results:The prob...


  • A 6-year study of mammographic compression force: Practitioner variability within and between screening sites

    by Claire E. Mercer, Katy Szczepura, Judith Kelly, Sara R. Millington, Erika R.E. Denton, Rita Borgen, Beverley Hilton, Peter Hogg


  • Extra patient movement during mammographic imaging: an experimental study

    by W K Ma, D Brettle, D Howard, J Kelly, S Millington, P Hogg

    Objective: To determine if movement external to the patient occurring during mammography may be a source of image blur. Methods: Four mammography machines with eight flexible and eight fixed paddles were evaluated. In the first stage, movement at the paddle was measured mechanically using two calibrated linear potentiometers. A deformable breast phantom was used to mimic a female breast. For each paddle, the movement in millimetres and change in compression force in Newton was recorded at 0.5- and 1-s intervals, respectively, for 40 s with the phantom in an initially compressed state under a load of 80 N. In the second stage, clinical audit on 28 females was conducted on one mammography machine with the 18 × 24- and 24 × 29-cm flexible paddles. Results: Movement at the paddle followed an exponential decay with a settling period of approximately 40 s. The compression force readings for both fixed and flexible paddles decreased exponentially with time, while fixed paddles had a larger drop in compression force than did flexible paddles. There is a linear relationship between movement at the paddle and change in compression force. Conclusion: Movement measured at the paddle during an exposure can be represented by a second order system. The amount of extra patient movement during the actual exposure can be estimated using the linear relationship between movement at the paddle and the change in compression force. Advances in knowledge: This research provides a possible explanation to mammography image blurring caused by extra patient movement and proposes a theoretical model to analyse the movement.