Optimization of the Electric Field Distribution at the End of the Stator in a Large Generator
Open Access
- 20 September 2018
- Vol. 11 (10) , 2510
Abstract
The electric field distribution at the end of a large hydro-generator is highly nonuniform and prone to corona discharge, which damages the main insulation and significantly reduces the service life of the hydro-generator. In order to reduce the thickness of the main insulation and the physical size of a large hydro-generator, it is necessary to understand the distribution of the electric field at the end of its stator bar. In this paper, the stator bar at the end of a large generator is simulated using the finite element method to determine the distribution of the potential, electric field, and loss at the rated voltage, as well as to elucidate the differences between the linear corona protection, two-segment nonlinear corona protection, and three-segment nonlinear corona protection structures. The influences of the arc angle, length of each corona protection layer, intrinsic resistivity of the corona protection material, and nonlinear coefficient are also analyzed. The results manifest that the angle of the stator bar should be 22.5°, the difference in resistivity between the two adjacent corona protection coatings should not exceed two orders of magnitude, and the resistivity of the medium resistivity layer should be nearly 106 Ω·m or 107 Ω·m, for an optimal design of the corona protection structure.Keywords
Funding Information
- National Natural Science Foundation of China (51577045, 11801121)
- Natural Science Foundation of Heilongjiang Province (QC2018006)
This publication has 18 references indexed in Scilit:
- Improvement of Corona Discharge Model and Its Application on Simulating Corona Discharge in the Presence of WindMathematical Problems in Engineering, 2017
- 600 mesh silicon carbide corona protection varnish with epoxy/OMMT nano-composite adhesiveJournal of Wuhan University of Technology-Mater. Sci. Ed., 2016
- Computationally Efficient 3-D Finite-Element-Based Dynamic Thermal Models of Electric MachinesIEEE Transactions on Transportation Electrification, 2015
- 3D Numerical Simulation of Heat Transfer of a Heated Plate under the Electric Field Generated by a Needle ElectrodeMathematical Problems in Engineering, 2014
- Motor and Generator WindingsIEEE Industry Applications Magazine, 2011
- Stator end-winding currents in frequency-domain dielectric response measurementsIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Effectiveness of Stress Grading Coatings on Form Wound Stator Coil Groundwall Insulation Under Fast Rise Time Pulse VoltagesIEEE Transactions on Energy Conversion, 2005
- Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windingsIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Stress grading for high voltage motor and generator coilsIEEE Electrical Insulation Magazine, 1995
- A calculation method and some features of transient field under polarity reversal voltage in HVDC insulationIEEE Transactions on Power Delivery, 1993