Extended scan depth optical coherence tomography for evaluating ocular surface shape
Authors:
- 1 January 2011
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (5) , 056007-056007-10
Abstract
Spectral domain optical coherence tomography (SD-OCT) with extended scan depth makes it possible for quantitative measurement of the entire ocular surface shape. We proposed a novel method for ocular surface shape measurement using a custom-built anterior segment SD-OCT, which will serve on the contact lens fitting. A crosshair alignment system was applied to reduce the misalignment and tilting of the eye. An algorithm was developed to automatically segment the ocular surface. We also described the correction of the image distortion from the segmented dataset induced by the nontelecentric scanning system and tested the accuracy and repeatability. The results showed high accuracy of SD-OCT in measuring a bicurved test surface with a maximum height error of 17.4 μm. The repeatability of in vivo measurement was also good. The standard deviations of the height measurement within a 14-mm wide range were all less than 35 μm. This work demonstrates the feasibility of using extended depth SD-OCT to perform noninvasive evaluation of the ocular surface shape.Keywords
This publication has 44 references indexed in Scilit:
- Application of optical coherence tomography to automated contact lens metrologyJournal of Biomedical Optics, 2010
- Extended in vivo anterior eye-segment imaging with full-range complex spectral domain optical coherence tomographyJournal of Biomedical Optics, 2009
- Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging rangeOptics Express, 2009
- Anterior segment imaging with Spectral OCT system using a high-speed CMOS cameraOptics Express, 2009
- Imaging the Ocular Anterior Segment With Real-Time, Full-Range Fourier-Domain Optical Coherence TomographyArchives of Ophthalmology (1950), 2008
- Compensating technique of field-distorting error for the CO2 laser galvanometric scanning drilling machinesInternational Journal of Machine Tools and Manufacture, 2007
- Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 13 µmOptics Express, 2005
- In Vivo Dehydration of Silicone Hydrogel Contact LensesEye & Contact Lens: Science & Clinical Practice, 2003
- Corneal topography and computerized contact lens-fitting modulesInternational Contact Lens Clinic, 1994
- Corneal Topography of KeratoconusCornea, 1991