Abstract
Sacrificial anodes were electrodissolved, and hydroxometal product are formed as coagulants, in simple and efficient treatment method known as electrocoagulation. One of the most significant hydrocarbon products in the contemporary world is oil. During different phases of production, transit, refinement, and usage, it may contaminate the environment. This research investigates the potential the process of electrocoagulation employing parallel plate stainless-steel and aluminum electrodes to remove phenol from effluent in refinery solution in a batch electrocoagulation (EC) method. A number of operational factors, including pH, NaCl addition, Examined were applied voltage and reaction time in an attempt to improve the removal capacity. Six monopolarly linked stainless-steel, aluminum electrodes were used in a batch reactor to treat the effluents. It was discovered that, under ideal circumstances, more than 98.5% of phenol can be removed. At an applied voltage of 25 V, a reaction time of 60 min, an electrode distance of 1 cm, an electrolyte concentration of 1.5 g L −1 , and a pH of 5, the greatest efficiency of phenol removal was achieved. The outcomes listed above demonstrate the potential of electrocoagulation as a method for treating industrial waste water. that liquid wastes containing phenol can be treated by electrocoagulation.

This publication has 34 references indexed in Scilit: