Shatha Younes Al-Samarrai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shatha Younes Al-Samarrai has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Anas Y. Al Hayawi2 shared publications
Ayoub I. Owed
2 shared publications- Kadhim Kh. Hashim
Al-Qasim Green University, Hillah, Babylon, Iraq
2 shared publications - Osamah J. Al-Sareji
Environmental Research and Studies Center, University of Babylon, Al-Hillah, Iraq
2 shared publications - Abdulkhaliq A. Moheimeed
Tikrit University
1 shared publication Abdulwahed A. Al – Jubouri
1 shared publication
Latest Publications
- 12 October 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 43, 397-405
Electrocoagulation Technology to Remove Phenol from Petroleum Wastewater
Sacrificial anodes were electrodissolved, and hydroxometal product are formed as coagulants, in simple and efficient treatment method known as electrocoagulation. One of the most significant hydrocarbon products in the contemporary world is oil. During different phases of production, transit, refinement, and usage, it may contaminate the environment. This research investigates the potential the process of electrocoagulation employing parallel plate stainless-steel and aluminum electrodes to remove phenol from effluent in refinery solution in a batch electrocoagulation (EC) method. A number of operational factors, including pH, NaCl addition, Examined were applied voltage and reaction time in an attempt to improve the removal capacity. Six monopolarly linked stainless-steel, aluminum electrodes were used in a batch reactor to treat the effluents. It was discovered that, under ideal circumstances, more than 98.5% of phenol can be removed. At an applied voltage of 25 V, a reaction time of 60 min, an electrode distance of 1 cm, an electrolyte concentration of 1.5 g L −1 , and a pH of 5, the greatest efficiency of phenol removal was achieved. The outcomes listed above demonstrate the potential of electrocoagulation as a method for treating industrial waste water. that liquid wastes containing phenol can be treated by electrocoagulation.
- 12 October 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 43, 397-405
Electrocoagulation Technology to Remove Phenol from Petroleum Wastewater
Sacrificial anodes were electrodissolved, and hydroxometal product are formed as coagulants, in simple and efficient treatment method known as electrocoagulation. One of the most significant hydrocarbon products in the contemporary world is oil. During different phases of production, transit, refinement, and usage, it may contaminate the environment. This research investigates the potential the process of electrocoagulation employing parallel plate stainless-steel and aluminum electrodes to remove phenol from effluent in refinery solution in a batch electrocoagulation (EC) method. A number of operational factors, including pH, NaCl addition, Examined were applied voltage and reaction time in an attempt to improve the removal capacity. Six monopolarly linked stainless-steel, aluminum electrodes were used in a batch reactor to treat the effluents. It was discovered that, under ideal circumstances, more than 98.5% of phenol can be removed. At an applied voltage of 25 V, a reaction time of 60 min, an electrode distance of 1 cm, an electrolyte concentration of 1.5 g L −1 , and a pH of 5, the greatest efficiency of phenol removal was achieved. The outcomes listed above demonstrate the potential of electrocoagulation as a method for treating industrial waste water. that liquid wastes containing phenol can be treated by electrocoagulation.
- 2 September 2026
- Published by Springer Nature
- p. 417-422
Dye Removal from Solutions Using the Electrocoagulation Method
- 2 September 2026
- Published by Springer Nature
- p. 417-422
Dye Removal from Solutions Using the Electrocoagulation Method
- 1 April 2026
- Published by Springer Nature
- p. 189-198
Green Synthesis of Ion Selective Electrode Nano Coated with Mint Leaf Extract for Efficient Copper Analysis in Wastewater
- 1 April 2026
- Published by Springer Nature
- p. 189-198
Green Synthesis of Ion Selective Electrode Nano Coated with Mint Leaf Extract for Efficient Copper Analysis in Wastewater
- 1 April 2026
- Published by Springer Nature
- p. 295-305
Design and Development of a Green Chemistry-Enabled Cobalt Oxide-Based Nano-Sensor Through Innovative Organic Precipitants
- 1 April 2026
- Published by Springer Nature
- p. 295-305
Design and Development of a Green Chemistry-Enabled Cobalt Oxide-Based Nano-Sensor Through Innovative Organic Precipitants
- Open Access
- 30 June 2025
- Published by University of Diyala, College of Education for Pure Sciences in Iraqi Journal for Applied Sciences
- Vol. 2 (2) , 71-82
Detection of Nickel Ions in Industrial Water by Fabricating Carbon Paste Electrode modified with Nanoparticles
Nickel must be carefully monitored due to its severe health and environmental impacts. Many innovative nickel ion detection (Ni+2) methods have been developed. These methods vary from fluorescent and nanoscale sensors to biosensors, optical electronics, and larger devices. In this research, a new detector electrode sensor was developed to detect and estimate nickel in industrial and well-water. Nickel oxide II (NiO) nanoparticles were synthesized using an extract of Capparis Spinosa leaves, washed, and dried. Then, the material from fresh green leaves has been extracted. The synthesized NiONPs were incorporated into a carbon paste matrix, forming a modified electrode for the selective detection of Ni+2 ions in aqueous samples. NiONPs and their external characteristics have been studied by various techniques. The particle size measured was approximately (15.57) nm. Scanning Electron Microscope SEM analysis revealed that the nanoparticles exhibited both spherical and irregular shapes. In the UV-VIS spectrometry, the peak was at the wavelength (366) nm; this confirms that nickel particles have been obtained. The electrode demonstrated selectivity and good sensitivity with linear response (10-1 - 10-9), correlation coefficient (0.9987), electrode lifespan (130) days, and the ideal temperatures for the electrode were measured and determined (15-40) °C. The best degree of acidity (pH) to work (5-8), with a slope value at (25) °C, was (28.5) mV/decade. Limit of detection 8.335x10-9 mol/L. The recovery percentage is 100.8%. This work successfully estimated nickel ions in wells and industrial waters.
- 30 June 2025
- Published by University of Diyala, College of Education for Pure Sciences in Iraqi Journal for Applied Sciences
- Vol. 2 (2) , 71-82
Open AccessDetection of Nickel Ions in Industrial Water by Fabricating Carbon Paste Electrode modified with Nanoparticles
Nickel must be carefully monitored due to its severe health and environmental impacts. Many innovative nickel ion detection (Ni+2) methods have been developed. These methods vary from fluorescent and nanoscale sensors to biosensors, optical electronics, and larger devices. In this research, a new detector electrode sensor was developed to detect and estimate nickel in industrial and well-water. Nickel oxide II (NiO) nanoparticles were synthesized using an extract of Capparis Spinosa leaves, washed, and dried. Then, the material from fresh green leaves has been extracted. The synthesized NiONPs were incorporated into a carbon paste matrix, forming a modified electrode for the selective detection of Ni+2 ions in aqueous samples. NiONPs and their external characteristics have been studied by various techniques. The particle size measured was approximately (15.57) nm. Scanning Electron Microscope SEM analysis revealed that the nanoparticles exhibited both spherical and irregular shapes. In the UV-VIS spectrometry, the peak was at the wavelength (366) nm; this confirms that nickel particles have been obtained. The electrode demonstrated selectivity and good sensitivity with linear response (10-1 - 10-9), correlation coefficient (0.9987), electrode lifespan (130) days, and the ideal temperatures for the electrode were measured and determined (15-40) °C. The best degree of acidity (pH) to work (5-8), with a slope value at (25) °C, was (28.5) mV/decade. Limit of detection 8.335x10-9 mol/L. The recovery percentage is 100.8%. This work successfully estimated nickel ions in wells and industrial waters.
- Open Access
- 30 June 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (2)
A nano-sensor for copper oxide was manufactured and developed using a new organic precipitant via green chemistry methods
Green chemistry methods were applied to fabricate a nanoelectrode to capture copper ions for the first time using the new organic reagent (4-(3-(2-(3-nitrophenyl)-4,7-dioxo-1,3-oxazepin-3(2H, 4H, (7H)- yl) thioureido. The ionic double was prepared to manufacture the new copper oxide nanoelectrode from the reaction of the new organic reagent and used it as an organic precipitant with CuO-NP nanoparticles prepared from cinnamon extract using the simple green aqueous method. Several techniques were used (XRD, FTIR, SEM) to characterize these particles. This electrode shows excellent selectivity and sensitivity with a linear range of (10-3 -10-13) M, correlation coefficient (0.9998), electrode life of 77 days, ideal temperatures (30) °C and range Optimum pH (3-9), slope (11.082 mV/decade), limit of detection (9.79×10-13) M. The average crystal size measured by the XRD device was (25) nm. The particles were seen by SEM as spherical. Or almost spherical in shape. UV-Visible spectroscopy, the peak was at wave length at (798) nm. This confirms that nanoparticles have been obtained for Copper material. Functional aggregates were determined by FTIR measurement. Recovery value of (101.1) %. This method was successfully applied to estimate copper ions in polluted water.
- 30 June 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (2)
Open AccessA nano-sensor for copper oxide was manufactured and developed using a new organic precipitant via green chemistry methods
Green chemistry methods were applied to fabricate a nanoelectrode to capture copper ions for the first time using the new organic reagent (4-(3-(2-(3-nitrophenyl)-4,7-dioxo-1,3-oxazepin-3(2H, 4H, (7H)- yl) thioureido. The ionic double was prepared to manufacture the new copper oxide nanoelectrode from the reaction of the new organic reagent and used it as an organic precipitant with CuO-NP nanoparticles prepared from cinnamon extract using the simple green aqueous method. Several techniques were used (XRD, FTIR, SEM) to characterize these particles. This electrode shows excellent selectivity and sensitivity with a linear range of (10-3 -10-13) M, correlation coefficient (0.9998), electrode life of 77 days, ideal temperatures (30) °C and range Optimum pH (3-9), slope (11.082 mV/decade), limit of detection (9.79×10-13) M. The average crystal size measured by the XRD device was (25) nm. The particles were seen by SEM as spherical. Or almost spherical in shape. UV-Visible spectroscopy, the peak was at wave length at (798) nm. This confirms that nanoparticles have been obtained for Copper material. Functional aggregates were determined by FTIR measurement. Recovery value of (101.1) %. This method was successfully applied to estimate copper ions in polluted water.
- Open Access
- 31 March 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Development and application of a nano-coated selective electrode for detection of iron in wastewater
This study investigates the possibility of determining iron in wastewater by green chemistry method, including developing an iron selective electrode coated with nano CG-FeO- NPs extracted from mint leaves. The developed electrode was characterised using AFM, SEM, XRD and IR technologies. The performance of the new electrode was optimised for the effects of the pH, temperature and response time. The results showed that the electrode works efficiently in a pH range of 5-8, a temperature range of 20-30 oC, and a response time of 6-88 seconds. The calibration curve was range line response from 10-1 to 10-11 with a slope of -28.727 mV/decade, a correlation coefficient of 0.9997, a detection limit of 2.4×10-10 M, a lifetime of 48 days and a recovery percentage of 98.5-99,80 for concentrations of 10-2,10-3 and 10-4. A selectivity test was also carried out to ensure no interferences with other elements such as zinc, potassium, sulfate, lead, calcium and manganese. Measurements proved that the electrode has high selectivity towards iron ions only and not other elements. Applications were carried out using the standard addition method on an industrial water model and gave a correlation coefficient of 0.9999.
- 31 March 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Open AccessDevelopment and application of a nano-coated selective electrode for detection of iron in wastewater
This study investigates the possibility of determining iron in wastewater by green chemistry method, including developing an iron selective electrode coated with nano CG-FeO- NPs extracted from mint leaves. The developed electrode was characterised using AFM, SEM, XRD and IR technologies. The performance of the new electrode was optimised for the effects of the pH, temperature and response time. The results showed that the electrode works efficiently in a pH range of 5-8, a temperature range of 20-30 oC, and a response time of 6-88 seconds. The calibration curve was range line response from 10-1 to 10-11 with a slope of -28.727 mV/decade, a correlation coefficient of 0.9997, a detection limit of 2.4×10-10 M, a lifetime of 48 days and a recovery percentage of 98.5-99,80 for concentrations of 10-2,10-3 and 10-4. A selectivity test was also carried out to ensure no interferences with other elements such as zinc, potassium, sulfate, lead, calcium and manganese. Measurements proved that the electrode has high selectivity towards iron ions only and not other elements. Applications were carried out using the standard addition method on an industrial water model and gave a correlation coefficient of 0.9999.
- Open Access
- 31 March 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Green nano-coated carbon electrodes for detecting furosemide drug
In this study, new coated carbon electrodes were created and utilized to estimate the furosemide (FUR) drug. Ion-pair preparation for the electrode construction involved a reaction of furosemide drug with silver nanoparticles (Ag-NPs) made from pomegranate peel extract, plasticizers that use dibutyl phthalate (DBP) without the use of any organic precipitant. Several techniques (AFM, XRD, FTIR, SEM) were used to characterize the characteristics. This electrode shows excellent sensitivity to furosemide (FUR) with a linear range of 10-6 -10-1 M and a correlation coefficient of 0.9798. The electrode has a lifetime of 45 days, ideal temperatures of 20-45 ºC, an optimum pH range of 3-6, a slope of 61.286 mv/decade, and a detection limit of 3.62×10-8 M. The AFM was measured, the total height was 2.53 nm, and the shape was spherical or semi-spherical. The average crystal size measured by XRD was 43.52, 47, and 55.03 nm with an average size of 14.25067 nm; the particles were spherical or semi-spherical in shape, as seen using the SEM. The identification of functional aggregates was conducted by measuring them using FTIR. In conclusion, this method could be an efficient tool for determining the drug in pharmaceutical formulations.
- 31 March 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Open AccessGreen nano-coated carbon electrodes for detecting furosemide drug
In this study, new coated carbon electrodes were created and utilized to estimate the furosemide (FUR) drug. Ion-pair preparation for the electrode construction involved a reaction of furosemide drug with silver nanoparticles (Ag-NPs) made from pomegranate peel extract, plasticizers that use dibutyl phthalate (DBP) without the use of any organic precipitant. Several techniques (AFM, XRD, FTIR, SEM) were used to characterize the characteristics. This electrode shows excellent sensitivity to furosemide (FUR) with a linear range of 10-6 -10-1 M and a correlation coefficient of 0.9798. The electrode has a lifetime of 45 days, ideal temperatures of 20-45 ºC, an optimum pH range of 3-6, a slope of 61.286 mv/decade, and a detection limit of 3.62×10-8 M. The AFM was measured, the total height was 2.53 nm, and the shape was spherical or semi-spherical. The average crystal size measured by XRD was 43.52, 47, and 55.03 nm with an average size of 14.25067 nm; the particles were spherical or semi-spherical in shape, as seen using the SEM. The identification of functional aggregates was conducted by measuring them using FTIR. In conclusion, this method could be an efficient tool for determining the drug in pharmaceutical formulations.
- RetractedOpen Access
- 29 February 2024
- Published by Elsevier in Environmental Research
- Vol. 251, 118565
RETRACTED: A novel and sustainable composite of L@PSAC for superior removal of pharmaceuticals from different water matrices: Production, characterization, and application
- 29 February 2024
- Published by Elsevier in Environmental Research
- Vol. 251, 118565
RetractedOpen AccessRETRACTED: A novel and sustainable composite of L@PSAC for superior removal of pharmaceuticals from different water matrices: Production, characterization, and application
- Open Access
- 10 January 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Determination, Manufacturing and application of a nanoparticle lead ion-selective electrode as a sensor in flow injection systems
This study involves the construction of ion-selective electrodes for the determination of lead (II) ions and their utilization as sensors in a flow-injection analysis (FIA) system. The electrode was constructed using a simple environmentally friendly method from a green tea extract, and a Lead acetate solution of the cited ions as a cylindrical disc. A vertical, side-to-side cylinder, the whole is created in its centre and another lateral hole is created for the electrical attachment of the electrode, so the prepared electrode is suitable for use with the FIA system. The electrode was studied surface properties and characteristics of this electrode were analysed using X-ray diffraction and Fourier-transform infrared spectroscopy (FTR). via selection of the optimum conditions (i.e. linear calibration range, lowest Nernstian response, lowest detection limit, degree of dilution, and precision and accuracy of their analytical uses). Electrode which gave the best Nernstian response1.00×10-1 to 1.00×10-10 M, a correlation coefficient of 0.9980, with lower Nernstian response of 1×10-10 M and detection limit of 1×10-11 M. The sampling rate was 120 samples per hour the calculated time of the contact of the sample with the electrode surface is 6 seconds and the degree of dilution is 2.37625.
- 10 January 2024
- Published by ScienVerse Ltd in Sensors and Machine Learning Applications
- Vol. 3 (1)
Open AccessDetermination, Manufacturing and application of a nanoparticle lead ion-selective electrode as a sensor in flow injection systems
This study involves the construction of ion-selective electrodes for the determination of lead (II) ions and their utilization as sensors in a flow-injection analysis (FIA) system. The electrode was constructed using a simple environmentally friendly method from a green tea extract, and a Lead acetate solution of the cited ions as a cylindrical disc. A vertical, side-to-side cylinder, the whole is created in its centre and another lateral hole is created for the electrical attachment of the electrode, so the prepared electrode is suitable for use with the FIA system. The electrode was studied surface properties and characteristics of this electrode were analysed using X-ray diffraction and Fourier-transform infrared spectroscopy (FTR). via selection of the optimum conditions (i.e. linear calibration range, lowest Nernstian response, lowest detection limit, degree of dilution, and precision and accuracy of their analytical uses). Electrode which gave the best Nernstian response1.00×10-1 to 1.00×10-10 M, a correlation coefficient of 0.9980, with lower Nernstian response of 1×10-10 M and detection limit of 1×10-11 M. The sampling rate was 120 samples per hour the calculated time of the contact of the sample with the electrode surface is 6 seconds and the degree of dilution is 2.37625.