Detection and Location of Stator Winding Interturn Fault at Different Slots of DFIG
Authors:
Open Access
- 3 July 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 89342-89353
Abstract
Generators are critical components for the wind power generation system and process industries. Generating units or production lines may be shut down by generator failure. Most of the methods used in previous research have analyzed the rotor winding interturn fault in the slot location or the stator winding interturn fault in the phase location, but the doubly-fed induction generator (DFIG) stator fault in the slot location still needs to be studied further because of the special topological structure and the real factors of the generator model. To solve this problem, this work determines the pulsating magnetomotive force (MMF) expressions mapped to the shorted position in two forms. Based on twodimensional discretization and piecewise interpolation, by taking the short-circuit number and the position of short-circuit slot as model parameters, the modified fault model is developed. Simulations show that as an interturn short-circuit fault occurs, the stator’s three-phase current is no longer symmetric, where the fault-phase current is bigger than that in healthy operation. In addition, the results show that interturn shortcircuit faults induce negative sequence current that increases with the gravity of fault in DFIG stator and that the phase difference of the fault-phase and its lagging phase is more than 120°. Moreover, commonality and heterogeneity existing in the current amplitude and negative sequence features for detecting stator interturn faults at different slots of the DFIG are proposed and analyzed. The results obtained in this paper are important complements to the stator interturn short-circuit analysis and help the practical monitoring and diagnosis of this fault.Keywords
Funding Information
- National Natural Science Foundation of China (51565008)
- Innovation-Driven Development Special Fund Project of Guangxi (Guike AA18242033, Guike AA18242036)
- GUET Excellent Graduate Thesis (17YJPYSS02)
- Innovation Project of GUET Graduate Education (2019YCXS001)
This publication has 25 references indexed in Scilit:
- Wavelet‐based index to discriminate between minor inter‐turn short‐circuit and resistive asymmetrical faults in stator windings of doubly fed induction generators: a simulation studyIET Generation, Transmission & Distribution, 2016
- Inter-turn short-circuit fault detection in saturable squirrel-cage induction motor using magnetic equivalent circuit modelCOMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2016
- Application of Ensemble Empirical Mode Decomposition on Stator Inter-turn Short-Circuit Fault in Doubly Fed Induction Generators2015
- Analysis of rotor and stator winding inter-turn faults in WRIM using simulated MEC model and experimental resultsElectric Power Systems Research, 2015
- Magnetic Field Finite Element Analysis of Generator with Rotor Inter-Turn Short-Circuit FaultApplied Mechanics and Materials, 2014
- FEM analysis on interturn fault of rotor wingding in DFIG2013
- Hybrid modelling of doubly fed induction generators with inter‐turn stator fault and its detection method using wavelet analysisIET Generation, Transmission & Distribution, 2013
- Voltage and frequency control in power generating system using hybrid evolutionary algorithmsJournal of Vibration and Control, 2011
- Finite element analysis of stiffness characteristics of an electromagnetic deviceJournal of Vibration and Control, 2011
- Operation of fault tolerant machines with winding failuresIEEE Transactions on Energy Conversion, 1999