Study of detection times for liver stiffness evaluation by shear wave elastography
Open Access
- 28 July 2014
- journal article
- research article
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 20 (28) , 9578-9584
Abstract
AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB). METHODS: One hundred and twelve CHB patients (25 women, 87 men) with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs. All patients underwent liver biopsy. Based on the biopsy pathology, the liver stiffness data obtained from different VMs (1, 2, 3, 5 and 10 times) were compared for the evaluation of liver fibrosis. The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed. The receiver operating characteristic (ROC) curve was employed to determine the diagnostic performance of different VMs of detection, and the areas under the ROC curve of different groups were compared. RESULTS: The liver stiffness values obtained from 1 VM, 2 VMs, 3 VMs, 5 VMs and all 10 VMs for stage F0 were 6.95 ± 2.01 kPa, 6.87 ± 1.83 kPa, 6.90 ± 1.88 kPa, 6.95 ± 1.93 kPa and 7.15 ± 1.89 kPa, respectively (F = 0.043, P = 0.996). For stage F1, these values were 7.12 ± 1.72 kPa, 7.24 ± 1.72 kPa, 7.21 ± 1.74 kPa, 7.10 ± 1.78 kPa and 7.04 ± 1.70 kPa, respectively (F = 0.075, P = 0.990). For stage F2, they were 9.37 ± 3.87 kPa, 9.18 ± 3.68 kPa, 9.19 ± 3.81 kPa, 9.18 ± 3.81 kPa and 9.19 ± 3.53 kPa, respectively (F = 0.012, P = 1.000). For stage F3, these were 11.91 ± 3.88 kPa, 11.78 ± 4.04 kPa, 11.83 ± 4.07 kPa, 11.94 ± 4.17 kPa and 12.00 ± 4.02 kPa, respectively (F = 0.010, P = 1.000). For stage F4, the readings were 19.30 ± 7.63 kPa, 19.40 ± 7.36 kPa, 19.54 ± 7.43 kPa, 19.73 ± 7.21 kPa and 20.25 ± 7.22 kPa, respectively (F = 0.054, P = 0.995). There were no significant differences between these groups. Intraclass correlation coefficients among different pathological stages (F0-F4) with different detection VMs were 0.995, 0.993, 0.996, 0.994 and 0.996, respectively. The mean elasticity values from 1 VM, 2 VMs, 3 VMs, 5 VMs and 10 VMs can accurately distinguish fibrosis stages (F0 vs F1234, F01 vs F234, F012 vs F34 and F0123 vs F4) with no significant differences in the five groups (P > 0.05 for all). CONCLUSION: One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB. However, future studies of larger patient samples are necessary for the validation of this method.Keywords
This publication has 20 references indexed in Scilit:
- Evolving therapies for liver fibrosisJournal of Clinical Investigation, 2013
- Factors that affect the diagnostic accuracy of liver fibrosis measurement by Fibroscan in patients with chronic hepatitis BAlimentary Pharmacology & Therapeutics, 2010
- Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability StudyUltrasound in Medicine & Biology, 2009
- Features associated with success rate and performance of fibroscan measurements for the diagnosis of cirrhosis in HCV patients: A prospective study of 935 patientsJournal of Hepatology, 2007
- Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinationsEuropean Journal of Gastroenterology & Hepatology, 2006
- Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis CGastroenterology, 2005
- Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis CHepatology, 2004
- Supersonic shear imaging: a new technique for soft tissue elasticity mappingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infectionAmerican Journal of Gastroenterology, 2002
- An Algorithm for the Grading of Activity in Chronic Hepatitis CHepatology, 1996