Rong-Qin Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rong-Qin Zheng has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
5 shared publications Ping Wang
Department of Ultrasonography, The Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, P. R. China
4 shared publicationsYang Xiao
Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
4 shared publicationsJie Ren
Departments of Medical Ultrasonics, Third Affiliated Hospital, Sun Yat‐Sen University, Guangzhou, People's Republic of China
3 shared publicationsLili Niu
Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
3 shared publicationsLong Meng
Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
3 shared publications
Latest Publications
- Open Access
- 24 May 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (44) , 78153-78162
Nanobubbles as ultrasound contrast agent for facilitating small cell lung cancer imaging
Background: This study is to investigate whether liposome-loaded nanobubbles (NBs) have the potentials to carry anti-pro-gastrin releasing peptide (proGRP) antibody and enhance ultrasound imaging of small cell lung cancer (SCLC).
- 24 May 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (44) , 78153-78162
Open AccessNanobubbles as ultrasound contrast agent for facilitating small cell lung cancer imaging
Background: This study is to investigate whether liposome-loaded nanobubbles (NBs) have the potentials to carry anti-pro-gastrin releasing peptide (proGRP) antibody and enhance ultrasound imaging of small cell lung cancer (SCLC).
- Open Access
- 19 July 2016
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 15 (1) , 1-8
The relationship between HbA1c and ultrasound plaque textures in atherosclerotic patients
Diabetes mellitus (DM) is associated to the morphological and componential characteristics of atheromatous plaques. It has proven that plaque textures are related to plaque components and beneficial for atherosclerotic risk stratification. The aim of this study is to compare plaque textures in patients with and without DM, and examine the relationship between HbA1c levels and the ultrasound plaque textures in atherosclerotic patients. A total of 136 participants (among them 66 are diabetic and 70 are non-diabetic) suffering from carotid plaques were included. About 300 texture features were extracted from the ultrasound images of plaques using the algorithms of histogram, absolute gradient, run-length matrix, gray-level co-occurrence matrix, autoregressive model and wavelet transform, respectively. Thirty optimal features were selected by the Fisher coefficient and the mutual information measure. The most discriminating feature (MDF) was obtained from the linear discriminant analysis for the optimal features. Linear regression model was performed to investigate the relationship between HbA1c and MDF. The receiver operating characteristics (ROC) curve was further developed to validate the relation between the estimated HbA1c (models output) and diabetes status. A total of 12 texture features showed statistical difference between patients with and without DM. The MDF was significant higher in non-diabetic patients (0.326 ± 0.049) than diabetic patients (−0.346 ± 0.052) (p < 0.001). The optimal regression model (r = 0.348, p < 0.001) for HbA1c included a constant (p < 0.001) and the MDF (p < 0.001). The areas under ROC curve used to estimate HbA1c was 0.828. The results indicate that there is a quantitative relationship between the HbA1c levels and plaque textures in ultrasonic images of atherosclerotic patients, which may suggest that texture analysis of the ultrasonic image of plaque is a promising method for evaluating the cardiovascular risk caused by DM in patients with plaques.
- 19 July 2016
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 15 (1) , 1-8
Open AccessThe relationship between HbA1c and ultrasound plaque textures in atherosclerotic patients
Diabetes mellitus (DM) is associated to the morphological and componential characteristics of atheromatous plaques. It has proven that plaque textures are related to plaque components and beneficial for atherosclerotic risk stratification. The aim of this study is to compare plaque textures in patients with and without DM, and examine the relationship between HbA1c levels and the ultrasound plaque textures in atherosclerotic patients. A total of 136 participants (among them 66 are diabetic and 70 are non-diabetic) suffering from carotid plaques were included. About 300 texture features were extracted from the ultrasound images of plaques using the algorithms of histogram, absolute gradient, run-length matrix, gray-level co-occurrence matrix, autoregressive model and wavelet transform, respectively. Thirty optimal features were selected by the Fisher coefficient and the mutual information measure. The most discriminating feature (MDF) was obtained from the linear discriminant analysis for the optimal features. Linear regression model was performed to investigate the relationship between HbA1c and MDF. The receiver operating characteristics (ROC) curve was further developed to validate the relation between the estimated HbA1c (models output) and diabetes status. A total of 12 texture features showed statistical difference between patients with and without DM. The MDF was significant higher in non-diabetic patients (0.326 ± 0.049) than diabetic patients (−0.346 ± 0.052) (p < 0.001). The optimal regression model (r = 0.348, p < 0.001) for HbA1c included a constant (p < 0.001) and the MDF (p < 0.001). The areas under ROC curve used to estimate HbA1c was 0.828. The results indicate that there is a quantitative relationship between the HbA1c levels and plaque textures in ultrasonic images of atherosclerotic patients, which may suggest that texture analysis of the ultrasonic image of plaque is a promising method for evaluating the cardiovascular risk caused by DM in patients with plaques.
- 28 April 2016
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 4 (6) , 979-988
Perfluorooctyl bromide traces self-assembled with polymeric nanovesicles for blood pool ultrasound imaging
A novel perfluorooctyl bromide (PFOB)-loaded nanovesicle with a size of about 500 nm was prepared by self-assembly of an amphiphilic block copolymer, poly(ethylene oxide)-b-poly(D,L-lactic acid) (PEG-PDLLA), for blood pool ultrasound imaging. The excellent compatibility of PFOB with the hydrophobic PDLLA block makes PFOB uniformly distribute and integrate well within the nanovesicle shell. In theory, both the compressibility and shell density of the nanovesicle as ultrasound scatterers are enhanced, resulting in much higher echo intensity compared to the other PFOB nanoparticles. In vitro and in vivo imaging results illustrate that these polymeric nanovesicles with extremely low content of PFOB show quite a good contrast-enhancing effect even if highly diluted in blood. Therefore this PFOB-loaded polymeric nanovesicle is anticipated to be applicable as an ultrasound contrast agent for normal angiography and specific imaging of capillary-abundant organs or tissues (e.g. tumors).
- 28 April 2016
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 4 (6) , 979-988
Perfluorooctyl bromide traces self-assembled with polymeric nanovesicles for blood pool ultrasound imaging
A novel perfluorooctyl bromide (PFOB)-loaded nanovesicle with a size of about 500 nm was prepared by self-assembly of an amphiphilic block copolymer, poly(ethylene oxide)-b-poly(D,L-lactic acid) (PEG-PDLLA), for blood pool ultrasound imaging. The excellent compatibility of PFOB with the hydrophobic PDLLA block makes PFOB uniformly distribute and integrate well within the nanovesicle shell. In theory, both the compressibility and shell density of the nanovesicle as ultrasound scatterers are enhanced, resulting in much higher echo intensity compared to the other PFOB nanoparticles. In vitro and in vivo imaging results illustrate that these polymeric nanovesicles with extremely low content of PFOB show quite a good contrast-enhancing effect even if highly diluted in blood. Therefore this PFOB-loaded polymeric nanovesicle is anticipated to be applicable as an ultrasound contrast agent for normal angiography and specific imaging of capillary-abundant organs or tissues (e.g. tumors).
- 22 March 2016
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (6) , 682-687
Standard deviation of carotid young's modulus and presence or absence of plaque improves prediction of coronary heart disease risk
Summary: Introduction: The stiffness of large arteries and the presence or absence of plaque are associated with coronary heart disease (CHD). Because arterial walls are biologically heterogeneous, the standard deviation of Young's modulus (YM‐std) of the large arteries may better predict coronary atherosclerosis. However, the role of YM‐std in the occurrence of coronary events has not been addressed so far. Therefore, this study investigated whether the carotid YM‐std and the presence or absence of plaque improved CHD risk prediction.Methods: One hundred and three patients with CHD (age 66 ± 11 years) and 107 patients at high risk of atherosclerosis (age 61 ± 7 years) were recruited. Carotid YM was measured by the vessel texture matching method, and YM‐std was calculated. Carotid intima‐media thickness was measured by the MyLab 90 ultrasound Platform employed dedicated software RF‐tracking technology.Results: In logistic regression analysis, YM‐std (OR = 1·010; 95% CI = 1·003–1·016), carotid plaque (OR = 16·759; 95% CI = 3·719–75·533) and YM‐std plus plaque (OR = 0·989; 95% CI = 0·981–0·997) were independent predictors of CHD. The traditional risk factors (TRF) plus YM‐std plus plaque model showed a significant improvement in area under the receiver‐operating characteristic curve (AUC), which increased from 0·717 (TRF only) to 0·777 (95% CI for the difference in adjusted AUC: 0·010–0·110).Conclusions: Carotid YM‐std is a powerful independent predictor of CHD. Adding plaque and YM‐std to TRF improves CHD risk prediction.
- 22 March 2016
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (6) , 682-687
Standard deviation of carotid young's modulus and presence or absence of plaque improves prediction of coronary heart disease risk
Summary: Introduction: The stiffness of large arteries and the presence or absence of plaque are associated with coronary heart disease (CHD). Because arterial walls are biologically heterogeneous, the standard deviation of Young's modulus (YM‐std) of the large arteries may better predict coronary atherosclerosis. However, the role of YM‐std in the occurrence of coronary events has not been addressed so far. Therefore, this study investigated whether the carotid YM‐std and the presence or absence of plaque improved CHD risk prediction.Methods: One hundred and three patients with CHD (age 66 ± 11 years) and 107 patients at high risk of atherosclerosis (age 61 ± 7 years) were recruited. Carotid YM was measured by the vessel texture matching method, and YM‐std was calculated. Carotid intima‐media thickness was measured by the MyLab 90 ultrasound Platform employed dedicated software RF‐tracking technology.Results: In logistic regression analysis, YM‐std (OR = 1·010; 95% CI = 1·003–1·016), carotid plaque (OR = 16·759; 95% CI = 3·719–75·533) and YM‐std plus plaque (OR = 0·989; 95% CI = 0·981–0·997) were independent predictors of CHD. The traditional risk factors (TRF) plus YM‐std plus plaque model showed a significant improvement in area under the receiver‐operating characteristic curve (AUC), which increased from 0·717 (TRF only) to 0·777 (95% CI for the difference in adjusted AUC: 0·010–0·110).Conclusions: Carotid YM‐std is a powerful independent predictor of CHD. Adding plaque and YM‐std to TRF improves CHD risk prediction.
- Open Access
- 4 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e111926
Detection of Subclinical Atherosclerosis in Asymptomatic Subjects Using Ultrasound Radiofrequency-Tracking Technology
Atherosclerosis is a chronic and systemic disease and its developmental process involves the synergism of multiple risk factors such as hypertension, dyslipidemia, diabetes, obesity and smoking. The diagnosis of subclinical atherosclerosis is essential for strategic guidance towards suitable treatments and efficient prevention against acute cardiovascular events. This study employed ultrasound radiofrequency (RF) tracking technology to characterize human carotid arteries in vivo in terms of intima-media thickness (IMT) and artery stiffness, and evaluated the statistical correlation between carotid IMT and stiffness, and the number of risk factors for atherosclerosis. A total of 160 asymptomatic subjects were enrolled. Ultrasound RF-tracking technology was employed to acquire carotid IMT and stiffness parameters: maximum IMT (MAXIMT), RF Quality IMT (RFQIMT), distensibility coefficient ( ), compliance coefficient ( ), index, index and local pulse wave velocity ( ). The subjects were categorized in four groups in terms of the number of risk factors: ‘zero’, ‘single’, ‘double’, and ‘multiple’, and statistical analyses of carotid IMT and stiffness parameters were performed between these different groups. The subjects (n = 145) with MAXIMT smaller than 1.0 mm matched the IMT criteria for non-atherosclerosis and were named as NA-subjects. Spearman’s rho correlation analysis of the whole group and the NA-subjects both showed that MAXIMT correlated positively with RFQIMT, , , and , and negatively with and (p<0.01). The analysis of covariance of NA-subjects showed significant differences between subjects with and without risk factors, and also showed significant differences between the ‘zero’, ‘single’, ‘double’, and ‘multiple’ groups. The carotid IMT and stiffness parameters obtained by the ultrasound RF-tracking technology were demonstrated to possess significant statistical correlation with the number of risk factors from 160 subjects, and these anatomical and mechanical parameters may potentially be used together with the IMT criteria to support subclinical atherosclerosis diagnosis.
- 4 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e111926
Open AccessDetection of Subclinical Atherosclerosis in Asymptomatic Subjects Using Ultrasound Radiofrequency-Tracking Technology
Atherosclerosis is a chronic and systemic disease and its developmental process involves the synergism of multiple risk factors such as hypertension, dyslipidemia, diabetes, obesity and smoking. The diagnosis of subclinical atherosclerosis is essential for strategic guidance towards suitable treatments and efficient prevention against acute cardiovascular events. This study employed ultrasound radiofrequency (RF) tracking technology to characterize human carotid arteries in vivo in terms of intima-media thickness (IMT) and artery stiffness, and evaluated the statistical correlation between carotid IMT and stiffness, and the number of risk factors for atherosclerosis. A total of 160 asymptomatic subjects were enrolled. Ultrasound RF-tracking technology was employed to acquire carotid IMT and stiffness parameters: maximum IMT (MAXIMT), RF Quality IMT (RFQIMT), distensibility coefficient ( ), compliance coefficient ( ), index, index and local pulse wave velocity ( ). The subjects were categorized in four groups in terms of the number of risk factors: ‘zero’, ‘single’, ‘double’, and ‘multiple’, and statistical analyses of carotid IMT and stiffness parameters were performed between these different groups. The subjects (n = 145) with MAXIMT smaller than 1.0 mm matched the IMT criteria for non-atherosclerosis and were named as NA-subjects. Spearman’s rho correlation analysis of the whole group and the NA-subjects both showed that MAXIMT correlated positively with RFQIMT, , , and , and negatively with and (p<0.01). The analysis of covariance of NA-subjects showed significant differences between subjects with and without risk factors, and also showed significant differences between the ‘zero’, ‘single’, ‘double’, and ‘multiple’ groups. The carotid IMT and stiffness parameters obtained by the ultrasound RF-tracking technology were demonstrated to possess significant statistical correlation with the number of risk factors from 160 subjects, and these anatomical and mechanical parameters may potentially be used together with the IMT criteria to support subclinical atherosclerosis diagnosis.
- Open Access
- 28 July 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 20 (28) , 9578-9584
Study of detection times for liver stiffness evaluation by shear wave elastography
AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB). METHODS: One hundred and twelve CHB patients (25 women, 87 men) with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs. All patients underwent liver biopsy. Based on the biopsy pathology, the liver stiffness data obtained from different VMs (1, 2, 3, 5 and 10 times) were compared for the evaluation of liver fibrosis. The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed. The receiver operating characteristic (ROC) curve was employed to determine the diagnostic performance of different VMs of detection, and the areas under the ROC curve of different groups were compared. RESULTS: The liver stiffness values obtained from 1 VM, 2 VMs, 3 VMs, 5 VMs and all 10 VMs for stage F0 were 6.95 ± 2.01 kPa, 6.87 ± 1.83 kPa, 6.90 ± 1.88 kPa, 6.95 ± 1.93 kPa and 7.15 ± 1.89 kPa, respectively (F = 0.043, P = 0.996). For stage F1, these values were 7.12 ± 1.72 kPa, 7.24 ± 1.72 kPa, 7.21 ± 1.74 kPa, 7.10 ± 1.78 kPa and 7.04 ± 1.70 kPa, respectively (F = 0.075, P = 0.990). For stage F2, they were 9.37 ± 3.87 kPa, 9.18 ± 3.68 kPa, 9.19 ± 3.81 kPa, 9.18 ± 3.81 kPa and 9.19 ± 3.53 kPa, respectively (F = 0.012, P = 1.000). For stage F3, these were 11.91 ± 3.88 kPa, 11.78 ± 4.04 kPa, 11.83 ± 4.07 kPa, 11.94 ± 4.17 kPa and 12.00 ± 4.02 kPa, respectively (F = 0.010, P = 1.000). For stage F4, the readings were 19.30 ± 7.63 kPa, 19.40 ± 7.36 kPa, 19.54 ± 7.43 kPa, 19.73 ± 7.21 kPa and 20.25 ± 7.22 kPa, respectively (F = 0.054, P = 0.995). There were no significant differences between these groups. Intraclass correlation coefficients among different pathological stages (F0-F4) with different detection VMs were 0.995, 0.993, 0.996, 0.994 and 0.996, respectively. The mean elasticity values from 1 VM, 2 VMs, 3 VMs, 5 VMs and 10 VMs can accurately distinguish fibrosis stages (F0 vs F1234, F01 vs F234, F012 vs F34 and F0123 vs F4) with no significant differences in the five groups (P > 0.05 for all). CONCLUSION: One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB. However, future studies of larger patient samples are necessary for the validation of this method.
- 28 July 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 20 (28) , 9578-9584
Open AccessStudy of detection times for liver stiffness evaluation by shear wave elastography
AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB). METHODS: One hundred and twelve CHB patients (25 women, 87 men) with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs. All patients underwent liver biopsy. Based on the biopsy pathology, the liver stiffness data obtained from different VMs (1, 2, 3, 5 and 10 times) were compared for the evaluation of liver fibrosis. The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed. The receiver operating characteristic (ROC) curve was employed to determine the diagnostic performance of different VMs of detection, and the areas under the ROC curve of different groups were compared. RESULTS: The liver stiffness values obtained from 1 VM, 2 VMs, 3 VMs, 5 VMs and all 10 VMs for stage F0 were 6.95 ± 2.01 kPa, 6.87 ± 1.83 kPa, 6.90 ± 1.88 kPa, 6.95 ± 1.93 kPa and 7.15 ± 1.89 kPa, respectively (F = 0.043, P = 0.996). For stage F1, these values were 7.12 ± 1.72 kPa, 7.24 ± 1.72 kPa, 7.21 ± 1.74 kPa, 7.10 ± 1.78 kPa and 7.04 ± 1.70 kPa, respectively (F = 0.075, P = 0.990). For stage F2, they were 9.37 ± 3.87 kPa, 9.18 ± 3.68 kPa, 9.19 ± 3.81 kPa, 9.18 ± 3.81 kPa and 9.19 ± 3.53 kPa, respectively (F = 0.012, P = 1.000). For stage F3, these were 11.91 ± 3.88 kPa, 11.78 ± 4.04 kPa, 11.83 ± 4.07 kPa, 11.94 ± 4.17 kPa and 12.00 ± 4.02 kPa, respectively (F = 0.010, P = 1.000). For stage F4, the readings were 19.30 ± 7.63 kPa, 19.40 ± 7.36 kPa, 19.54 ± 7.43 kPa, 19.73 ± 7.21 kPa and 20.25 ± 7.22 kPa, respectively (F = 0.054, P = 0.995). There were no significant differences between these groups. Intraclass correlation coefficients among different pathological stages (F0-F4) with different detection VMs were 0.995, 0.993, 0.996, 0.994 and 0.996, respectively. The mean elasticity values from 1 VM, 2 VMs, 3 VMs, 5 VMs and 10 VMs can accurately distinguish fibrosis stages (F0 vs F1234, F01 vs F234, F012 vs F34 and F0123 vs F4) with no significant differences in the five groups (P > 0.05 for all). CONCLUSION: One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB. However, future studies of larger patient samples are necessary for the validation of this method.
- 1 March 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (3) , 461-469
Influence of Measurement Depth on the Stiffness Assessment of Healthy Liver with Real-Time Shear Wave Elastography
- 1 March 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (3) , 461-469
Influence of Measurement Depth on the Stiffness Assessment of Healthy Liver with Real-Time Shear Wave Elastography
- Open Access
- 2 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e67809
Impact of Multiple Cardiovascular Risk Factors on Carotid Intima-Media Thickness and Elasticity
Carotid intima-media thickness (IMT) and elasticity have been shown to be independent predictors of cardiovascular disease (CVD). Cardiovascular risk factors (CVRFs) includes hypertension, dyslipidemia, diabetes, overweight and smoking. The objective was to investigate whether the clustering of three or more components of CVRFs has a greater impact on carotid IMT and elasticity than individual components of CVRFs. One hundred and seventy-three participants without clinical CVD were classified as the multiple CVRFs patients with three or more CVRFs (n = 55) and control group with two or less CVRFs (n = 118). Carotid IMT and elastic modulus were measured by B-mode ultrasound and vessel texture matching method (VTMM), respectively. The multiple CVRFs conferred a disproportionate increase in carotid IMT (43%, p<0.0001) and elastic modulus (60%, p<0.0001), compared with control group. Multiple regression models, which included age, gender, as well as each individual component of CVRFs as continuous variables, showed that multiple CVRFs was an independent determinant of both IMT (p = 0.042) and elasticity (p = 0.008). In the analysis of variance adjusted with age, subjects with single, double, and multiple CVRFs, increased by 8.1%, 42.2%, and 66% for IMT, 54.6%, 94.3%, and 125.2% for elastic modulus, respectively, compared to subjects without CVRFs. The clustering of multiple CVRFs has a greater impact on carotid IMT and elasticity than individual components of CVRFs. This suggests that the components of CVRFs interact to synergistically impact carotid IMT and elasticity.
- 2 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e67809
Open AccessImpact of Multiple Cardiovascular Risk Factors on Carotid Intima-Media Thickness and Elasticity
Carotid intima-media thickness (IMT) and elasticity have been shown to be independent predictors of cardiovascular disease (CVD). Cardiovascular risk factors (CVRFs) includes hypertension, dyslipidemia, diabetes, overweight and smoking. The objective was to investigate whether the clustering of three or more components of CVRFs has a greater impact on carotid IMT and elasticity than individual components of CVRFs. One hundred and seventy-three participants without clinical CVD were classified as the multiple CVRFs patients with three or more CVRFs (n = 55) and control group with two or less CVRFs (n = 118). Carotid IMT and elastic modulus were measured by B-mode ultrasound and vessel texture matching method (VTMM), respectively. The multiple CVRFs conferred a disproportionate increase in carotid IMT (43%, p<0.0001) and elastic modulus (60%, p<0.0001), compared with control group. Multiple regression models, which included age, gender, as well as each individual component of CVRFs as continuous variables, showed that multiple CVRFs was an independent determinant of both IMT (p = 0.042) and elasticity (p = 0.008). In the analysis of variance adjusted with age, subjects with single, double, and multiple CVRFs, increased by 8.1%, 42.2%, and 66% for IMT, 54.6%, 94.3%, and 125.2% for elastic modulus, respectively, compared to subjects without CVRFs. The clustering of multiple CVRFs has a greater impact on carotid IMT and elasticity than individual components of CVRFs. This suggests that the components of CVRFs interact to synergistically impact carotid IMT and elasticity.
- Open Access
- 1 February 2012
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 7, 895-904
Nanobubbles for enhanced ultrasound imaging of tumors
The fabrication and initial applications of nanobubbles (NBs) have shown promising results in recent years. A small particle size is a basic requirement for ultrasound contrast-enhanced agents that penetrate tumor blood vessel pores to allow for targeted imaging and therapy. However, the nanoscale size of the particles used has the disadvantage of weakening the imaging ability of clinical diagnostic ultrasound. In this work, we fabricated a lipid NBs contrast-enhanced ultrasound agent and evaluated its passive targeting ability in vivo. The results showed that the NBs were small (436.8 ± 5.7 nm), and in vitro ultrasound imaging suggested that the ultrasonic imaging ability is comparable to that of microbubbles (MBs). In vivo experiments confirmed the ability of NBs to passively target tumor tissues. The NBs remained in the tumor area for a longer period because they exhibited enhanced permeability and retention. Direct evidence was obtained by direct observation of red fluorescence-dyed NBs in tumor tissue using confocal laser scanning microscopy. We have demonstrated the ability to fabricate NBs that can be used for the in vivo contrast-enhanced imaging of tumor tissue and that have potential for drug/gene delivery.
- 1 February 2012
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 7, 895-904
Open AccessNanobubbles for enhanced ultrasound imaging of tumors
The fabrication and initial applications of nanobubbles (NBs) have shown promising results in recent years. A small particle size is a basic requirement for ultrasound contrast-enhanced agents that penetrate tumor blood vessel pores to allow for targeted imaging and therapy. However, the nanoscale size of the particles used has the disadvantage of weakening the imaging ability of clinical diagnostic ultrasound. In this work, we fabricated a lipid NBs contrast-enhanced ultrasound agent and evaluated its passive targeting ability in vivo. The results showed that the NBs were small (436.8 ± 5.7 nm), and in vitro ultrasound imaging suggested that the ultrasonic imaging ability is comparable to that of microbubbles (MBs). In vivo experiments confirmed the ability of NBs to passively target tumor tissues. The NBs remained in the tumor area for a longer period because they exhibited enhanced permeability and retention. Direct evidence was obtained by direct observation of red fluorescence-dyed NBs in tumor tissue using confocal laser scanning microscopy. We have demonstrated the ability to fabricate NBs that can be used for the in vivo contrast-enhanced imaging of tumor tissue and that have potential for drug/gene delivery.
- Open Access
- 1 March 2010
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 16 (6) , 729-735
Contrast-enhanced ultrasound for the evaluation of hepatic artery stenosis after liver transplantation: potential role in changing the clinical algorithm
Hepatic artery stenosis (HAS) is a common complication in liver transplant patients. Conventional angiography remains the gold standard for diagnosis. Recently, contrast-enhanced ultrasound (CEUS) has begun providing real-time angiographic-like images of vessels and allowing the accurate diagnosis of arterial diseases such as hepatic artery thrombosis. The purpose of this study was to evaluate the efficacy of CEUS in depicting HAS after liver transplantation. Forty-seven liver transplant recipients underwent CEUS examinations with the intravenous injection of microbubble contrast agents. The reference standard was conventional angiography for 15 patients and computed tomographic angiography for 32 patients. The presence, degree, location, and type of HAS were evaluated. For the detection of HAS by CEUS, the following was found: an accuracy of 91.5% (43/47), a sensitivity of 92.3% (36/39), a specificity of 87.5% (7/8), a positive predictive value of 97.3% (36/37), and a negative predictive value of 70% (7/10). CEUS corrected false-positive findings on color Doppler ultrasound in 7 of 47 cases (14.9%). The accuracy of CEUS in identifying the location and type of HAS was 92.3% (36/39) and 84.6% (33/39), respectively. CEUS is a useful noninvasive technique for the detection of HAS in liver transplant patients because it provides comprehensive information, including the presence, location, degree, and type. A positive CEUS finding suggests angiography as the next step rather than a computed tomography scan and may thereby alter the clinical imaging algorithm. Liver Transpl 16:729-735, 2010. © 2010 AASLD.
- 1 March 2010
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 16 (6) , 729-735
Open AccessContrast-enhanced ultrasound for the evaluation of hepatic artery stenosis after liver transplantation: potential role in changing the clinical algorithm
Hepatic artery stenosis (HAS) is a common complication in liver transplant patients. Conventional angiography remains the gold standard for diagnosis. Recently, contrast-enhanced ultrasound (CEUS) has begun providing real-time angiographic-like images of vessels and allowing the accurate diagnosis of arterial diseases such as hepatic artery thrombosis. The purpose of this study was to evaluate the efficacy of CEUS in depicting HAS after liver transplantation. Forty-seven liver transplant recipients underwent CEUS examinations with the intravenous injection of microbubble contrast agents. The reference standard was conventional angiography for 15 patients and computed tomographic angiography for 32 patients. The presence, degree, location, and type of HAS were evaluated. For the detection of HAS by CEUS, the following was found: an accuracy of 91.5% (43/47), a sensitivity of 92.3% (36/39), a specificity of 87.5% (7/8), a positive predictive value of 97.3% (36/37), and a negative predictive value of 70% (7/10). CEUS corrected false-positive findings on color Doppler ultrasound in 7 of 47 cases (14.9%). The accuracy of CEUS in identifying the location and type of HAS was 92.3% (36/39) and 84.6% (33/39), respectively. CEUS is a useful noninvasive technique for the detection of HAS in liver transplant patients because it provides comprehensive information, including the presence, location, degree, and type. A positive CEUS finding suggests angiography as the next step rather than a computed tomography scan and may thereby alter the clinical imaging algorithm. Liver Transpl 16:729-735, 2010. © 2010 AASLD.