Development and Validation of a Digitizer-Based TCSPC System for Scintillation Decay Time Analysis via an Extended Convolution Model
Open Access
Abstract
The development of high-fidelity digital twins for scintillation spectrometer detectors demands precise experimental characterization of timing parameters. This work presents a comprehensive solution comprising a digitizer-based time-correlated single-photon counting (TCSPC) system and an extended convolution model for decay time analysis. We introduce a physics-driven calibration principle, validating the system response against an independent physical benchmark to ensure fidelity. The proposed convolution model advances beyond the conventional model by incorporating additional parameters to account for scintillator-induced timing broadening and delay, thereby decoupling this effect from instrumental response. The model’s descriptive power was statistically validated through its application to fast scintillators, while its physical accuracy was robustly confirmed through the precise extraction of typical decay times from slow scintillators. This methodology establishes a reliable workflow from measurement to parameterization, directly supplying the decoupled inputs required for the digital twins of scintillation detectors.Keywords
Funding Information
- National Institute of Metrology, China (AKYZZ2528)
- National Natural Science Foundation of China (12441508)
This publication has 23 references indexed in Scilit:
- Silicon Photomultipliers and SPAD imagers in biophotonics: Advances and perspectivesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Precise rise and decay time measurements of inorganic scintillators by means of X-ray and 511 keV excitationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- AIC under the framework of least squares estimationApplied Mathematics Letters, 2017
- Modeling crosstalk and afterpulsing in silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- On the comparison of analog and digital SiPM readout in terms of expected timing performanceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- A new pulse model for NaI(Tl) detection systemsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Time resolution deterioration with increasing crystal length in a TOF-PET systemNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- New Photonis XP20D0 photomultiplier for fast timing in nuclear medicineNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- A method to increase optical timing spectra measurement rates using a multi-hit TDCNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- Timing properties of BGO scintillatorNuclear Instruments and Methods in Physics Research, 1981