Juncheng Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juncheng Liang has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Haoran Liu
National Institute of Metrology, Beijing, 100029, CHINA
7 shared publicationsZhijie Yang
National Institute of Metrology, Beijing, 100029, CHINA
7 shared publicationsZihao Fan
National Institute of Metrology, Beijing, 100029, CHINA
4 shared publicationsQianqian Zhou
National Institute of Metrology, Beijing, 100029, China; State Key Laboratory of Chemistry for NBC Hazards Protection, P.O. Box 1044 Ext. 203, Beijing, 102205, China
3 shared publicationsYifan Tian
National Institute of Metrology, Beijing, 100029, China; China University of Geosciences, Beijing, 100083, China
3 shared publicationsChanghao Sun
National Institute of Metrology, Beijing, China
2 shared publications
Latest Publications
- 1 March 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 232, 112490
Development of SIRTI at National Institute of Metrology (NIM), China
- 1 March 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 232, 112490
Development of SIRTI at National Institute of Metrology (NIM), China
- Open Access
Development and Validation of a Digitizer-Based TCSPC System for Scintillation Decay Time Analysis via an Extended Convolution Model
The development of high-fidelity digital twins for scintillation spectrometer detectors demands precise experimental characterization of timing parameters. This work presents a comprehensive solution comprising a digitizer-based time-correlated single-photon counting (TCSPC) system and an extended convolution model for decay time analysis. We introduce a physics-driven calibration principle, validating the system response against an independent physical benchmark to ensure fidelity. The proposed convolution model advances beyond the conventional model by incorporating additional parameters to account for scintillator-induced timing broadening and delay, thereby decoupling this effect from instrumental response. The model’s descriptive power was statistically validated through its application to fast scintillators, while its physical accuracy was robustly confirmed through the precise extraction of typical decay times from slow scintillators. This methodology establishes a reliable workflow from measurement to parameterization, directly supplying the decoupled inputs required for the digital twins of scintillation detectors.
Open AccessDevelopment and Validation of a Digitizer-Based TCSPC System for Scintillation Decay Time Analysis via an Extended Convolution Model
The development of high-fidelity digital twins for scintillation spectrometer detectors demands precise experimental characterization of timing parameters. This work presents a comprehensive solution comprising a digitizer-based time-correlated single-photon counting (TCSPC) system and an extended convolution model for decay time analysis. We introduce a physics-driven calibration principle, validating the system response against an independent physical benchmark to ensure fidelity. The proposed convolution model advances beyond the conventional model by incorporating additional parameters to account for scintillator-induced timing broadening and delay, thereby decoupling this effect from instrumental response. The model’s descriptive power was statistically validated through its application to fast scintillators, while its physical accuracy was robustly confirmed through the precise extraction of typical decay times from slow scintillators. This methodology establishes a reliable workflow from measurement to parameterization, directly supplying the decoupled inputs required for the digital twins of scintillation detectors.
- 3 November 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112283
Enhanced α/β discrimination in liquid scintillation via UMAP-HDBSCAN
- 3 November 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112283
Enhanced α/β discrimination in liquid scintillation via UMAP-HDBSCAN
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05043
Performance optimizations and evaluations for the small direct currents measurement system
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the ionization current measurement capability of the 4πγ ionization chamber radioactivity standard at the National Institute of Metrology (NIM), China. Besides, it has broad application prospects in physical experiments and fundamental metrology. The design of the measurement system is optimized through circuit analysis and simulation. The structure of the integrating capacitor array is redesigned to reduce the error of the amplification gain, and a relay is used as the reset switch to achieve improved noise and leakage performance. The digital readout and control module is also enhanced in terms of flexibility and functionality. High-precision test platforms utilizing the standard small current source at NIM China and an ionization chamber were developed to evaluate the performance of the system. The results demonstrate an ultra-low noise floor (< 1 fA/√Hz) and a low current bias of fA-level, as well as a low temperature coefficient of the amplification gain of 2.1 ppm/°C. The short-term stability and linearity of the gain are also tested and exhibit comparable indicators to those of the Keithley 6430. Reasonable results are obtained in the long-term reproducibility test. Therefore, the system enables high-precision measurements for small direct currents and shows promise for applications in ionization chambers.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05043
Performance optimizations and evaluations for the small direct currents measurement system
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the ionization current measurement capability of the 4πγ ionization chamber radioactivity standard at the National Institute of Metrology (NIM), China. Besides, it has broad application prospects in physical experiments and fundamental metrology. The design of the measurement system is optimized through circuit analysis and simulation. The structure of the integrating capacitor array is redesigned to reduce the error of the amplification gain, and a relay is used as the reset switch to achieve improved noise and leakage performance. The digital readout and control module is also enhanced in terms of flexibility and functionality. High-precision test platforms utilizing the standard small current source at NIM China and an ionization chamber were developed to evaluate the performance of the system. The results demonstrate an ultra-low noise floor (< 1 fA/√Hz) and a low current bias of fA-level, as well as a low temperature coefficient of the amplification gain of 2.1 ppm/°C. The short-term stability and linearity of the gain are also tested and exhibit comparable indicators to those of the Keithley 6430. Reasonable results are obtained in the long-term reproducibility test. Therefore, the system enables high-precision measurements for small direct currents and shows promise for applications in ionization chambers.
- 30 April 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (5) , 3683-3687
Activity determination of 131I solution
- 30 April 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (5) , 3683-3687
Activity determination of 131I solution
- 6 December 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 958, 177766
Effects of tritium pollution on photosynthesis, respiration and redox of microalgae under rising temperature
- 6 December 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 958, 177766
Effects of tritium pollution on photosynthesis, respiration and redox of microalgae under rising temperature
- 1 October 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 214, 111537
Development of a TDCR counting system with anti-coincidence detectors
- 1 October 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 214, 111537
Development of a TDCR counting system with anti-coincidence detectors
- 2 August 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110971
The calibration of transfer standards for the measurement of 222Rn at NIM
- 2 August 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110971
The calibration of transfer standards for the measurement of 222Rn at NIM
- 7 September 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 189, 110449
Influence of the detector on calculation of self-attenuation correction factor of volume sources
- 7 September 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 189, 110449
Influence of the detector on calculation of self-attenuation correction factor of volume sources
- Open Access
- 3 August 2022
- Published by Elsevier in SSRN Electronic Journal
Assessing Obt Formation and Enrichment: ROS Signaling is Involved in the Radiation Hormesis Induced by Low- Dose Tritium Exposure in Algae
Tritium is the main component of radioactive wastewater and can be migrated into organisms to form OBT, which may pose a potential risk to aquatic ecosystem. Hence, it is essential to monitor OBT conversion in the presence of tritium exposure. In this study, the effects of pretreatment methods such as digestion on the recovery of tritium were discussed. It was found that microwave digestion pretreatment could improve the recovery of tritium by up to 90% and allow OBT measurement with a small sample size equivalent to about 60 mg (dry weight). In addition, the efficiency of OBT transformation was different among biological samples, and the radiation hormesis phenomenon was induced by low-dose tritium exposure in microalgae Chlorella vulgaris . Low-dose tritium exposure may induce radiation hormesis through the reactive oxygen species signaling pathway, thus improving the photosynthetic capacity and metabolism level of C. vulgaris . Furthermore, enhancement of photorespiration metabolism and the antioxidation system may be important means for C. vulgaris to balance damage by low doses of tritium radiation. This study provides insights for further investigating OBT behavior, and will contribute to understanding the equilibrium damage mechanism of algae exposed to low doses of tritium.
- 3 August 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessAssessing Obt Formation and Enrichment: ROS Signaling is Involved in the Radiation Hormesis Induced by Low- Dose Tritium Exposure in Algae
Tritium is the main component of radioactive wastewater and can be migrated into organisms to form OBT, which may pose a potential risk to aquatic ecosystem. Hence, it is essential to monitor OBT conversion in the presence of tritium exposure. In this study, the effects of pretreatment methods such as digestion on the recovery of tritium were discussed. It was found that microwave digestion pretreatment could improve the recovery of tritium by up to 90% and allow OBT measurement with a small sample size equivalent to about 60 mg (dry weight). In addition, the efficiency of OBT transformation was different among biological samples, and the radiation hormesis phenomenon was induced by low-dose tritium exposure in microalgae Chlorella vulgaris . Low-dose tritium exposure may induce radiation hormesis through the reactive oxygen species signaling pathway, thus improving the photosynthetic capacity and metabolism level of C. vulgaris . Furthermore, enhancement of photorespiration metabolism and the antioxidation system may be important means for C. vulgaris to balance damage by low doses of tritium radiation. This study provides insights for further investigating OBT behavior, and will contribute to understanding the equilibrium damage mechanism of algae exposed to low doses of tritium.