Abstract
In permanent magnet (PM) machines, a turn-turn short-circuit (SC) fault is the most critical fault to eradicate. The fault introduces high SC current in the shorted turn, which may consequently lead to secondary faults unless the fault is appropriately controlled. This paper proposes feasible conductors' placement in a slot of a PM machine to minimize such turn-turn fault current. In order to minimize the fault current, the conductor arrangement in a slot is optimized using a multi-objective genetic algorithm incorporating with both analytical and finite-element numerical tool. The possible combinations of conductors' placement are set as variables and optimized for a given machine, which is designed for safety critical applications. It is shown that the fault current associated with a single turn fault can be significant for the random winding placement, even though the remedial strategies are put in place. It is also shown that the fault current can be significantly limited by rearranging the winding placement in a way to share slot-leakage fluxes. This is confirmed via experiment on E-core. Influences of the winding arrangement on both frequency-dependent resistances and winding's capacitances are experimented. It is demonstrated that adopting the winding arrangement that shares the slot-leakage flux effectively benefits to minimize the ac losses in addition to improved fault tolerance. But it increases the turn-turn capacitances whose effect, however, can be neglected as the resonance frequency occurs beyond the operational frequency range of the machines of interest.