Puvan Arumugam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Puvan Arumugam has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Chris Gerada
University of Nottingham
18 shared publications Tahar Hamiti
12 shared publications- Serhiy Bozhko
Power Electronics Machines and Control Institute, University of Nottingham, Nottingham NG7 2GT, UK
5 shared publications Jiri Dusek
3 shared publicationsWeeramundage Fernando
Department of Electrical and Electronic Engineering, University of Nottingham, Nottingham, U.K.
3 shared publicationsAnthony Aigbomian
Power Electronics Machines and Control (PEMC) Group, Division of Electrical Systems and Optics Faculty of Engineering, University of Nottingham, Nottingham, U.K
2 shared publications
Latest Publications
- 3 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 4 (4) , 985-996
Development of Aircraft Electric Starter–Generator System Based on Active Rectification Technology
More-electric aircraft (MEA) has become a dominant trend for modern aircraft. On-board MEA, many functions, which are conventionally driven by pneumatic and hydraulic power, are replaced with electrical subsystems. Starting aircraft engines with an electrical motor instead of using pneumatic power from the auxiliary power unit (APU) is one of the major characteristics of future aircraft. This paper presents the development of a novel electric starter-generator system for aircraft applications. The paper describes the main achievements of the project within the key areas including electric machines, power electronic converters, thermal management and overall system control design. The developed prototype has been tested successfully and the test results are presented in this paper.
- 3 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 4 (4) , 985-996
Development of Aircraft Electric Starter–Generator System Based on Active Rectification Technology
More-electric aircraft (MEA) has become a dominant trend for modern aircraft. On-board MEA, many functions, which are conventionally driven by pneumatic and hydraulic power, are replaced with electrical subsystems. Starting aircraft engines with an electrical motor instead of using pneumatic power from the auxiliary power unit (APU) is one of the major characteristics of future aircraft. This paper presents the development of a novel electric starter-generator system for aircraft applications. The paper describes the main achievements of the project within the key areas including electric machines, power electronic converters, thermal management and overall system control design. The developed prototype has been tested successfully and the test results are presented in this paper.
- 12 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1311-1320
Design of a Stator for a High-Speed Turbo-Generator With Fixed Permanent Magnet Rotor Radius and Volt–Ampere Constraints
This paper investigates high-speed surface PM machine design for portable turbo-generator applications. A magnet retention mechanism is used in the rotor due to high-speed operation, and the rotor radius is fixed to achieve certain optimal characteristics. The basis of this paper is to design the stator when the rotor radius has been fixed. The stator designs are populated by different slot/pole combinations, winding arrangements and over a range of possible stack lengths. However, the design is constrained by physical diameter, stack length and electrical volt-ampere constraints. A large number of preliminary machine designs do not satisfy the specified torque/speed requirements under the given volt-ampere constraints and therefore it is ineffective to perform Finite Element analysis on all preliminary design variations. In order to establish the feasibility of a machine design to fulfil the specified torque/speed requirements, the concept of inductance-limits is presented and then linked with stator design parameters. By application of this analysis strategy, a confined optimal set of stator designs are obtained and are subjected to detailed finite element simulations. A final machine design is selected and fabricated. Experimental results are presented for the validation of the final machine design.
- 12 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1311-1320
Design of a Stator for a High-Speed Turbo-Generator With Fixed Permanent Magnet Rotor Radius and Volt–Ampere Constraints
This paper investigates high-speed surface PM machine design for portable turbo-generator applications. A magnet retention mechanism is used in the rotor due to high-speed operation, and the rotor radius is fixed to achieve certain optimal characteristics. The basis of this paper is to design the stator when the rotor radius has been fixed. The stator designs are populated by different slot/pole combinations, winding arrangements and over a range of possible stack lengths. However, the design is constrained by physical diameter, stack length and electrical volt-ampere constraints. A large number of preliminary machine designs do not satisfy the specified torque/speed requirements under the given volt-ampere constraints and therefore it is ineffective to perform Finite Element analysis on all preliminary design variations. In order to establish the feasibility of a machine design to fulfil the specified torque/speed requirements, the concept of inductance-limits is presented and then linked with stator design parameters. By application of this analysis strategy, a confined optimal set of stator designs are obtained and are subjected to detailed finite element simulations. A final machine design is selected and fabricated. Experimental results are presented for the validation of the final machine design.
- 2 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (12) , 9784-9794
Design Optimization of a Short-Term Duty Electrical Machine for Extreme Environment
This paper presents design optimization of a short-term duty electrical machine for extreme environments of high temperature and high altitudes. For such extreme environmental conditions of above 80°C and altitudes of 30 km, thermal loading limits are a critical consideration in machines, especially if high power density and high efficiency are to be achieved. The influence of different material on the performance of such machines is investigated. Also, the effect of different slot and pole combinations are studied for machines used for such extreme operating conditions but with short duty. In the research, a nondominated sorting genetic algorithm (NSGAII) considering an analytical electromagnetic model, structural and thermal model together with finite element methods are used to optimize the design of the machine for such environments achieving high efficiencies and high power density with relatively minimal computational time. The adopted thermal model is then validated through experiments and then implemented within the genetic algorithm. It is shown that, generally, the designs are thermally limited where the pole numbers are limited by volt-amps drawn from the converter. The design consisting of a high slot number allows for improving the current loading and thus, significant weight reduction can be achieved.
- 2 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (12) , 9784-9794
Design Optimization of a Short-Term Duty Electrical Machine for Extreme Environment
This paper presents design optimization of a short-term duty electrical machine for extreme environments of high temperature and high altitudes. For such extreme environmental conditions of above 80°C and altitudes of 30 km, thermal loading limits are a critical consideration in machines, especially if high power density and high efficiency are to be achieved. The influence of different material on the performance of such machines is investigated. Also, the effect of different slot and pole combinations are studied for machines used for such extreme operating conditions but with short duty. In the research, a nondominated sorting genetic algorithm (NSGAII) considering an analytical electromagnetic model, structural and thermal model together with finite element methods are used to optimize the design of the machine for such environments achieving high efficiencies and high power density with relatively minimal computational time. The adopted thermal model is then validated through experiments and then implemented within the genetic algorithm. It is shown that, generally, the designs are thermally limited where the pole numbers are limited by volt-amps drawn from the converter. The design consisting of a high slot number allows for improving the current loading and thus, significant weight reduction can be achieved.
- 1 December 2016
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 130, 48-56
Modeling and analysis of eddy current losses in permanent magnet machines with multi-stranded bundle conductors
- 1 December 2016
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 130, 48-56
Modeling and analysis of eddy current losses in permanent magnet machines with multi-stranded bundle conductors
- 11 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (5) , 1-8
Design Optimization on Conductor Placement in the Slot of Permanent Magnet Machines to Restrict Turn–Turn Short-Circuit Fault Current
In permanent magnet (PM) machines, a turn-turn short-circuit (SC) fault is the most critical fault to eradicate. The fault introduces high SC current in the shorted turn, which may consequently lead to secondary faults unless the fault is appropriately controlled. This paper proposes feasible conductors' placement in a slot of a PM machine to minimize such turn-turn fault current. In order to minimize the fault current, the conductor arrangement in a slot is optimized using a multi-objective genetic algorithm incorporating with both analytical and finite-element numerical tool. The possible combinations of conductors' placement are set as variables and optimized for a given machine, which is designed for safety critical applications. It is shown that the fault current associated with a single turn fault can be significant for the random winding placement, even though the remedial strategies are put in place. It is also shown that the fault current can be significantly limited by rearranging the winding placement in a way to share slot-leakage fluxes. This is confirmed via experiment on E-core. Influences of the winding arrangement on both frequency-dependent resistances and winding's capacitances are experimented. It is demonstrated that adopting the winding arrangement that shares the slot-leakage flux effectively benefits to minimize the ac losses in addition to improved fault tolerance. But it increases the turn-turn capacitances whose effect, however, can be neglected as the resonance frequency occurs beyond the operational frequency range of the machines of interest.
- 11 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (5) , 1-8
Design Optimization on Conductor Placement in the Slot of Permanent Magnet Machines to Restrict Turn–Turn Short-Circuit Fault Current
In permanent magnet (PM) machines, a turn-turn short-circuit (SC) fault is the most critical fault to eradicate. The fault introduces high SC current in the shorted turn, which may consequently lead to secondary faults unless the fault is appropriately controlled. This paper proposes feasible conductors' placement in a slot of a PM machine to minimize such turn-turn fault current. In order to minimize the fault current, the conductor arrangement in a slot is optimized using a multi-objective genetic algorithm incorporating with both analytical and finite-element numerical tool. The possible combinations of conductors' placement are set as variables and optimized for a given machine, which is designed for safety critical applications. It is shown that the fault current associated with a single turn fault can be significant for the random winding placement, even though the remedial strategies are put in place. It is also shown that the fault current can be significantly limited by rearranging the winding placement in a way to share slot-leakage fluxes. This is confirmed via experiment on E-core. Influences of the winding arrangement on both frequency-dependent resistances and winding's capacitances are experimented. It is demonstrated that adopting the winding arrangement that shares the slot-leakage flux effectively benefits to minimize the ac losses in addition to improved fault tolerance. But it increases the turn-turn capacitances whose effect, however, can be neglected as the resonance frequency occurs beyond the operational frequency range of the machines of interest.
- 17 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (4) , 1-9
Impact of Slot/Pole Combination on Inter-Turn Short-Circuit Current in Fault-Tolerant Permanent Magnet Machines
This paper investigates the influence of the slot/pole (S/P) combination on inter-turn short-circuit (SC) current in fault-tolerant permanent magnet (FT-PM) machines. A 2-D sub-domain field computational model with multi-objective genetic algorithm is used for the design and performance prediction of the considered FT-PM machines. The electromagnetic losses of machines, including iron, magnet, and winding losses are systematically computed using analytical tools. During the postprocessing stage, a 1-D analysis is employed for turn-turn fault analysis. The method calculates self- and mutual inductances of both the faulty and healthy turns under an SC fault condition with respect to the fault locations, and thus SC fault current, considering its location. Eight FT-PM machines with different S/P combinations are analyzed. Both the performance of the machine during normal operation and induced currents during a turn-turn SC fault are investigated. To evaluate the thermal impact of each S/P combination under an inter-turn fault condition, a thermal analysis is performed using finite element computation. It is shown that low-rotor-pole-number machines have a better fault tolerance capability, while high-rotor-pole-number machines are lighter and provide higher efficiency. Results show that the influence of the S/P selection on inter-turn fault SC current needs to be considered during the design process to balance the efficiency and power density against fault-tolerant criteria of the application at hand.
- 17 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 52 (4) , 1-9
Impact of Slot/Pole Combination on Inter-Turn Short-Circuit Current in Fault-Tolerant Permanent Magnet Machines
This paper investigates the influence of the slot/pole (S/P) combination on inter-turn short-circuit (SC) current in fault-tolerant permanent magnet (FT-PM) machines. A 2-D sub-domain field computational model with multi-objective genetic algorithm is used for the design and performance prediction of the considered FT-PM machines. The electromagnetic losses of machines, including iron, magnet, and winding losses are systematically computed using analytical tools. During the postprocessing stage, a 1-D analysis is employed for turn-turn fault analysis. The method calculates self- and mutual inductances of both the faulty and healthy turns under an SC fault condition with respect to the fault locations, and thus SC fault current, considering its location. Eight FT-PM machines with different S/P combinations are analyzed. Both the performance of the machine during normal operation and induced currents during a turn-turn SC fault are investigated. To evaluate the thermal impact of each S/P combination under an inter-turn fault condition, a thermal analysis is performed using finite element computation. It is shown that low-rotor-pole-number machines have a better fault tolerance capability, while high-rotor-pole-number machines are lighter and provide higher efficiency. Results show that the influence of the S/P selection on inter-turn fault SC current needs to be considered during the design process to balance the efficiency and power density against fault-tolerant criteria of the application at hand.
- Open Access
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 9 (9) , 634-641
Turn–turn short circuit fault management in permanent magnet machines
This study presents a systematic study on turn–turn short circuit (SC) fault and ways to manage them to provide a basis for comparison of the various options available. The possible methods to reduce the likelihood of the winding SC fault and the fault mitigation techniques related to such faults are discussed. A finite‐element analysis of a surface‐mounted permanent magnet machine under application of different mitigation techniques during a turn–turn fault is presented. Both machine and drive structural adaptations for different fault mitigation techniques are addressed. Amongst the investigated fault mitigation techniques, the most promising solution is identified and validated experimentally. It is shown that the shorting terminal method adopting vertical winding arrangement is an effective method in terms of the implementation, reliability and weight.
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 9 (9) , 634-641
Open AccessTurn–turn short circuit fault management in permanent magnet machines
This study presents a systematic study on turn–turn short circuit (SC) fault and ways to manage them to provide a basis for comparison of the various options available. The possible methods to reduce the likelihood of the winding SC fault and the fault mitigation techniques related to such faults are discussed. A finite‐element analysis of a surface‐mounted permanent magnet machine under application of different mitigation techniques during a turn–turn fault is presented. Both machine and drive structural adaptations for different fault mitigation techniques are addressed. Amongst the investigated fault mitigation techniques, the most promising solution is identified and validated experimentally. It is shown that the shorting terminal method adopting vertical winding arrangement is an effective method in terms of the implementation, reliability and weight.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21659400,p. 1-5
Selection of slot-pole combination of permanent magnet machines for aircraft actuation
This paper investigates the influence of the slot/pole (S/P) combination on inter-turn short circuit (SC) current in fault tolerant permanent magnet (FT-PM) machines. Eight different S/P combinations are studied. For the investigation, methods based both on 1D and 2D analytical models were adopted. The 2D analytical model is used in combination with genetic algorithm (GA) optimisation to design the FT-PM machine, then a 1D analysis is used to estimate the SC current. It is shown that S/P combination has a significant influence on inter-turn SC fault current and needs to be considered during the design to balance the performance and fault tolerant criteria of the application.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21659400,p. 1-5
Selection of slot-pole combination of permanent magnet machines for aircraft actuation
This paper investigates the influence of the slot/pole (S/P) combination on inter-turn short circuit (SC) current in fault tolerant permanent magnet (FT-PM) machines. Eight different S/P combinations are studied. For the investigation, methods based both on 1D and 2D analytical models were adopted. The 2D analytical model is used in combination with genetic algorithm (GA) optimisation to design the FT-PM machine, then a 1D analysis is used to estimate the SC current. It is shown that S/P combination has a significant influence on inter-turn SC fault current and needs to be considered during the design to balance the performance and fault tolerant criteria of the application.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A review on turn-turn short circuit fault management
Permanent Magnet (PM) machines are increasingly being used in safety critical systems in aerospace and automotive applications. In such applications, reliability and availability are key concerns. Numerous works have been presented in literature which take into account both system reliability and availability in the event of single fault within the PM machine. This paper mainly focuses on a turn Short-Circuit (SC) fault and presents a systematic review on proposed methodologies to accommodate such faults. The possible methods to reduce the likelihood of the winding SC fault, and the available fault mitigation techniques related to such faults, are reviewed. It is shown that there is a tradeoff involved between reliability and the machines' performance.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A review on turn-turn short circuit fault management
Permanent Magnet (PM) machines are increasingly being used in safety critical systems in aerospace and automotive applications. In such applications, reliability and availability are key concerns. Numerous works have been presented in literature which take into account both system reliability and availability in the event of single fault within the PM machine. This paper mainly focuses on a turn Short-Circuit (SC) fault and presents a systematic review on proposed methodologies to accommodate such faults. The possible methods to reduce the likelihood of the winding SC fault, and the available fault mitigation techniques related to such faults, are reviewed. It is shown that there is a tradeoff involved between reliability and the machines' performance.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 959-964
Winding concepts for ultra reliable electrical machines
This paper investigates two winding concepts for Permanent Magnet (PM) machines used for more electric aircraft systems where reliability is a concern. Analysis is carried out using two different surface mounted PM machines designed for low and high speed applications: a 12 slot, 10 pole machine with concentrated windings for rotorcraft swashplate actuation and a 36-slot 6-pole machine with distributed winding arrangement for an aircraft starter-generator. The impact of the winding arrangement for the low speed machine is investigated with a focus on turn-turn Short-Circuit (SC) faults. Implications of the SC fault and methods to restrain the resulting SC current are discussed. A prognostics method for potential turn-turn SC faults for the high speed application is then investigated. It is shown that potential winding faults can be detected at an early stage of fault inception and thus measures can be taken to limit propagation.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 959-964
Winding concepts for ultra reliable electrical machines
This paper investigates two winding concepts for Permanent Magnet (PM) machines used for more electric aircraft systems where reliability is a concern. Analysis is carried out using two different surface mounted PM machines designed for low and high speed applications: a 12 slot, 10 pole machine with concentrated windings for rotorcraft swashplate actuation and a 36-slot 6-pole machine with distributed winding arrangement for an aircraft starter-generator. The impact of the winding arrangement for the low speed machine is investigated with a focus on turn-turn Short-Circuit (SC) faults. Implications of the SC fault and methods to restrain the resulting SC current are discussed. A prognostics method for potential turn-turn SC faults for the high speed application is then investigated. It is shown that potential winding faults can be detected at an early stage of fault inception and thus measures can be taken to limit propagation.