Practicability for robot-aided measurement of knee stability in-vivo
Open Access
- 3 December 2015
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 373
Abstract
For the analysis of different treatments concerning anterior cruciate ligament (ACL) rupture, objective methods for the quantification of knee stability are needed. Therefore, a new method for in-vivo stability measurement using a robotic testing system should be developed and evaluated. A new experimental setting was developed using a KUKA robot and a custom-made chair for the positioning and fixation of the participants. The tibia was connected to the robot via a Vacoped shoe and magnetic buttons, providing adequate safety. Anterior tibial translation and internal tibial rotation were measured on both legs of 40 healthy human subjects at 30°, 60° and 90° of flexion, applying anterior forces of 80 N and internal torques of 4 Nm, respectively. While the mean differences between the right and left leg measured for anterior tibial translation were within an acceptable range (<1.5 mm), the absolute values were substantially large (38–40.5 mm). For mean internal tibial rotation, between 17.5 and 20° were measured at the different sides and flexion angles, with a maximal difference of 0.75°. High reproducibility of the measurements could be demonstrated for both, anterior tibial translation (ICC(3,1) = 0.97) and internal tibial rotation (ICC(3,1) = 0.94). Excellent results were achieved for internal tibial rotation, almost reproducing current in-vitro studies, but too large anterior tibial translation was measured due to soft-tissue compression. Therefore, high potential for the analysis of ACL related treatments concerning rotational stability is seen for the proposed method, but further optimization is necessary to enhance this method for the reliable measurement of anterior tibial translation.Keywords
Funding Information
- ENDO-Stiftung (DE)
This publication has 43 references indexed in Scilit:
- A prospective randomised study of anatomical single-bundle versus double-bundle anterior cruciate ligament reconstruction: quantitative evaluation using an electromagnetic measurement systemInternational Orthopaedics, 2010
- Kinematic Impact of Anteromedial and Posterolateral Bundle Graft Fixation Angles on Double-Bundle Anterior Cruciate Ligament ReconstructionsThe American Journal of Sports Medicine, 2010
- Rotational knee laxity: Reliability of a simple measurement device in vivoBMC Musculoskeletal Disorders, 2008
- Stability comparison of anterior cruciate ligament between double- and single-bundle reconstructionsInternational Orthopaedics, 2008
- Measurement of varus–valgus and internal–external rotational knee laxities in vivo—Part II: relationship with anterior–posterior and general joint laxity in males and femalesJournal of Orthopaedic Research, 2007
- High prevalence of osteoarthritis 14 years after an anterior cruciate ligament tear in male soccer players: a study of radiographic and patient relevant outcomesAnnals of the Rheumatic Diseases, 2004
- Distribution of in situ forces in the anterior cruciate ligament in response to rotatory loadsJournal of Orthopaedic Research, 2004
- Repeatability of the KT-1000 arthrometer in a normal populationThe American Journal of Sports Medicine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruptionThe American Journal of Sports Medicine, 1985