Impact of breathing frequency on respiratory oscillometry measurements: a randomised cross-over and observational study of asthma patients
Open Access
- 23 February 2026
- journal article
- research article
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 13 (1) , e003657
Abstract
Introduction: The impact of breathing frequency on respiratory oscillometry measurements is unknown. We aimed to investigate the impact of different breathing frequencies in patients with asthma. Method: We recruited patients from the severe asthma clinic at Cambridge University Hospitals. Using a randomised-crossover design, participants performed the forced oscillation technique at three different breathing frequencies (15, 30, 40 bpm) in a randomised order for each participant. A metronome was used to ensure the correct breathing frequency. Analysis of variance (ANOVA) and Friedman tests were utilised to assess the significance of any differences across the breathing frequencies. We then leveraged cross-sectional data from asthma patients who performed respiratory oscillometry and investigated the determinants of self-selected breathing frequency using multivariable linear regression. Results: We recruited 59 patients. Mean age 54.1 years, 58% female, median forced expiratory volume in 1 s (FEV 1 )/FVC z-score −2.56 (−3.26 to −1.96). As breathing frequency increased from 15 bpm to 40 bpm, there was a significant reduction (−8.6%, p<0.001) in total airway resistance (Rrs at 5 Hz), which was not mediated by changes in tidal volume or flow rate. There was also a significant reduction (−14.9%, p<0.001) in Delta R5–R19, and an increase (+10.9%, p=0.081) in reactance (Xrs at 5 Hz). At higher breathing frequencies, 5% of study participants were reclassified as having respiratory oscillometry measurements within normal limits. Data from 796 asthma patients were extracted for the cross-sectional analysis. The median (range) self-selected breathing frequency was 16.55 bpm (8.0, 42.0). Demographic data and lung function explained 23.5% of the variation in breathing frequency. Conclusion: Higher breathing frequencies significantly reduce total Rrs . When performing respiratory oscillometry, breathing frequency should be controlled at approximately 15 bpm to reduce risk of misclassification.Keywords
This publication has 29 references indexed in Scilit:
- Understanding and checking the assumptions of linear regression: a primer for medical researchersClinical & Experimental Ophthalmology, 2014
- Respiratory impedance in healthy subjects: baseline values and bronchodilator responseEuropean Respiratory Journal, 2013
- Multi-ethnic reference values for spirometry for the 3–95-yr age range: the global lung function 2012 equationsEuropean Respiratory Journal, 2012
- Impact of obesity on respiratory functionRespirology, 2011
- Resistance and reactance in oscillation lung function reflect basal lung function and bronchial hyperresponsiveness respectivelyRespirology, 2009
- Sex differences in the resistive and elastic work of breathing during exercise in endurance-trained athletesAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2009
- Distal Airway Function Assessed by Oscillometry at Varying Respiratory Rate: Comparison with Dynamic ComplianceCOPD: Journal of Chronic Obstructive Pulmonary Disease, 2009
- Prevalence of dysfunctional breathing in patients treated for asthma in primary care: cross sectional surveyBMJ, 2001
- Influence of lung volume dependence of upper airway resistance during continuous negative airway pressureJournal of Applied Physiology, 1994
- Oscillation Mechanics of Lungs and Chest in ManJournal of Applied Physiology, 1956