KSKarl Peter Sylvester

Karl Peter Sylvester

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karl Peter Sylvester has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SpO 2 recovery time improves prognostic assessment in interstitial lung disease

    by Lucy Robertson, Helen Parfrey, Nicola Simler, Muhunthan Thillai, Karl Peter Sylvester, Ben Knox-Brown

    Introduction: Six-minute walk test (6MWT) parameters assess prognosis in interstitial lung disease (ILD). While exercise-induced desaturation and six-minute walk distance (6MWD) are established predictors, the prognostic value of oxygen saturation (SpO 2 ) recovery time is less clear and is not included in current 6MWT risk models like distance-oxygen gender age physiology (DO-GAP) and oxygen flow rate, distance, dyspnoea and saturation (ODDS), Methods: 323 ILD patients undergoing 6MWT at Royal Papworth Hospital NHS Foundation Trust were included. SpO 2 recovery time was defined as the time taken for SpO 2 % to return within 2% of baseline following 6MWT. Associations with 1- and 2-year mortality or lung transplantation were assessed using ROC analysis, Kaplan–Meier curves, and Cox regression. Incremental prognostic value was evaluated by adding SpO 2 recovery time to DO-GAP and ODDS models using C-index, AIC, and likelihood ratio testing. Results: SpO 2 recovery demonstrated good discrimination for 1- and 2-year outcomes (AUC 0.75 and 0.73). Kaplan–Meier and pairwise analyses showed a graded association between recovery time and outcomes, with significant differences between 120 s, although separation was greatest for >120 s. In multivariable analysis, TLCO (HR 0.94, 95% CI 0.92–0.96, p120 s (HR 2.11, 95% CI 1.04–4.29, p=0.039) were independently associated with outcomes. Addition of SpO 2 recovery improved ODDS model performance (p120 s) independently predicted outcomes and improved existing developed risk models in ILD.

  • Open Access

    Physiological quotients for discriminating mortality and respiratory outcomes: a UK biobank cohort study

    by Ben Knox-Brown, Karl P Sylvester, Andre F. S. Amaral

    Background: Spirometry is traditionally interpreted using reference-based metrics derived from equations such as those from the Global Lung Function Initiative (GLI). Physiological quotients, which express lung function relative to a lower physiological boundary, have been proposed as an alternative approach. We aimed to compare the prognostic performance of physiological quotients with conventional reference-based metrics including both the GLI 2012 ethnicity-specific and the GLI 2023 Global equations, in a large population-based cohort. Methods: We analysed data from 270 599 UK Biobank participants aged 40–69 years with baseline spirometry. Physiological quotients were calculated for FEV 1 , FVC, and FEV 1 /FVC using previously established first percentile boundaries. Associations with all-cause and cause-specific mortality, respiratory hospitalisation, respiratory symptoms, and self-reported respiratory diagnoses were examined using Cox proportional hazards and logistic regression models. Results: Over a median follow-up of 15.7 years, 26 197 (10%) participants died. Lower physiological quotients were consistently associated with adverse outcomes. Each 1- sd decrement in FEV 1 Q, FVCQ, and FEV 1 /FVCQ was associated with higher all-cause mortality (HRs 1.06–1.09), cardiovascular mortality (HRs 1.06–1.20), respiratory mortality (HRs 1.28–1.77), and respiratory hospitalisation (HRs 1.04–1.41). Discrimination for all-cause mortality was modest (C-statistics 0.64–0.65), moderate for cardiovascular mortality (0.72–0.73), and good for respiratory mortality (0.76–0.79). Discrimination of respiratory hospitalisation was modest but slightly higher for FEV 1 Q and FVCQ (0.65) than for percent predicted values and z-scores (0.61–0.62). Across mortality outcomes, discriminative performance was similar between physiological quotients, percent predicted values, and z-scores. Conclusion: Physiological quotients demonstrated prognostic performance comparable to conventional reference-based spirometric metrics for mortality outcomes, while showing modest advantages for respiratory morbidity.

  • Open Access

    Rethinking normality in cardiopulmonary exercise testing: why percentile-based thresholds deserve a greater role

    by Karl P. Sylvester, J. Alberto Neder

    Extract Clinical interpretation of any biological test aimed at assessing the presence of disease depends on careful judgement of the test results in light of the pre-test likelihood of abnormality. At first glance, this seems a relatively trivial task; in practice, however, there are tantalising complexities stemming from multiple sources, such as large test variability, technical issues, reference values that might not be appropriate for the specific population being examined, scarce ancillary information to guide the reader, and critically, how to safely separate “normal” from “abnormal”. Shareable abstract A study in the current issue of ERJ Open Research reinforces the need for modernised reference standards for CPET underscored on statistically sound distribution-based approaches https://bit.ly/42o9B9A

  • Delivering the NHS Long‑Term Plan: Outcomes from a Digitally Enabled Community Breathlessness Service in the UK

    by Karl P Sylvester, Kelly Pauley, Ella O'NEill, Martin Knolle

    Breathlessness has multifactorial causes leading to delayed diagnosis and inefficient, hospital‑centred pathways. The NHS 10‑Year Health Plan prioritises earlier and more accurate diagnosis, analogue‑to‑digital transformation, and a shift from hospital to community care. We evaluated how our integrated Breathlessness Service delivers these ambitions. A retrospective analysis of 2025 referrals was undertaken. Diagnostic contributors (N=55) and pathway timings were extracted from structured proformas and EPIC workflow data. Key metrics included time to triage, diagnostics, MDT review, and discharge. Common diagnostic contributors (in isolation or in combination) were: Breathing Pattern Disorder 49%, anxiety 33%, obesity 29%, asthma 25%, COPD/emphysema 9%; other contributors (musculoskeletal, anaemia, ILD, allergy) each 3.6%. Pathway timings demonstrated accelerated access: referral to triage 1 day (median); referral to first diagnostic 20 days; referral to first MDT 39 days; triage to diagnostic 16 days; diagnostic to MDT 16 days. Patients without CPET had referral to discharge in 39 days, compared with 78.7 days when CPET was required. This is in comparison to an eight-week wait to see a respiratory physician. All referrals, diagnostics and MDT actions were captured digitally via EPIC, supporting the national shift from analogue to digital. Most patients were managed fully within community‑based pathways, aligning with the NHS move from hospital to community. This service delivers rapid, holistic assessment and digitally integrated care for complex breathlessness, demonstrating real‑world implementation of NHS Long‑Term Plan reforms. Improved timelines, digital integration, and community‑based MDT care highlight its potential as a scalable model for modern respiratory services.

  • Open Access

    Current use and future potential of oscillometry in UK lung function testing: a national survey

    by Madison E Geeves, Michael J Hughes, Harry S Griffin, Karl P Sylvester, Zoe L Saynor

    Background: Despite growing international momentum, uptake of oscillometry in routine lung function testing services in the United Kingdom (UK) is unclear. Objectives: Evaluate the current use of oscillometry in UK lung function services, identify key clinical applications, and explore barriers to wider adoption. Methods: A cross-sectional e-survey, including multiple-choice and free-text responses, was distributed to members of the Association for Respiratory Technology and Physiology (ARTP) and reported in line with the Checklist for Reporting Results of Internet E-Surveys (CHERRIES). Results: A total of 42 National Health Service (NHS) respiratory services responded. Of these, 40% reported owning an oscillometry device, equally split between forced oscillation technique (Resmon Pro) and impulse oscillometry (Vyntus IOS), with one using both. Oscillometry is already used in clinical practice in 69% of these services, most commonly for adults (57%) but also in paediatrics (21%) and both (21%). It is primarily used in asthma (100%) and chronic obstructive pulmonary disease (57%), and in 86% of cases for patients unable to perform technically acceptable spirometry. Among services without a device, 50% were actively considering purchasing within five years. The main barrier cited was funding (67%). A lack of clinical understanding was identified, with 86% of services perceiving respiratory consultants to have ‘little’ understanding of oscillometry, and 10% reporting ‘none’. Almost all respondents (95%) supported the development of national guidance from ARTP outlining benefits, limitations and reporting standards. Conclusion: Despite increasing interest, oscillometry is not yet routinely adopted across UK lung function services. It is predominantly used as an alternative to spirometry when technically acceptable results cannot be achieved and as an additional tool to support asthma care. This national survey highlights the need to improve awareness, training and standardisation. Collaboration with the ARTP to establish national guidance represents an important next step toward wider implementation in clinical practice.

  • ERS technical standard on reference values for cardiopulmonary exercise testing: summary report and a call for action

    by Thomas Radtke, Luis Chávez, Lauren Duggan, Sanja Stanojevic, Piergiuseppe Agostoni, Paul Burns, Brenda Button, Christopher B. Cooper, Jana De Brandt, Luiza Helena Degani-Costa, et al.

    Background: Cardiopulmonary exercise testing (CPET) assesses physiological responses to incremental exercise and identifies potential causes of exercise limitation. There have been several population-specific reference equations published, but none that span the human age range. It would be advantageous to have all-age global reference ranges. This task force aimed to derive Global Lung Function Initiative reference equations for peak oxygen uptake ( V̇ O 2 peak ) and peak work rate (W peak ) in healthy individuals. Methods: CPET data were collected retrospectively. Generalised additive models of location, shape and scale were used to develop reference ranges, including age, sex, height and weight as explanatory variables. The influence of geographic region, equipment, testing protocols and averaging methods for peak exercise data were also examined. Results: Data from 5956 healthy individuals aged between 6 and 83 years across 17 sites in Europe, North and South America and Asia were analysed. There was substantial between-subject variability in both V̇ O 2 peak and W peak , with wide confidence intervals across age groups. Heterogeneity in V̇ O 2 peak was related to geographic region, metabolic cart type, and averaging methods for peak exercise values. Controlling for these variables improved model fit, but not sufficiently to be reliable predictors for reference ranges. Conclusion: Significant heterogeneity in CPET testing methodology and outcomes between sites precluded the development of reference ranges for V̇ O 2 peak and W peak . This task force has developed a framework for prospective data collection with strictly standardised protocols and centralised data analysis to reduce variability and establish robust, clinically meaningful reference ranges for CPET outcomes.


  • Open Access

    Pulmonary function test parameters before liver transplantation predict post-transplant survival and respiratory-related death

    by Lauren C.Y. Tang, Georgeina L. Jarman, Karl P. Sylvester, Saur Hajiev, Timothy Baker, Sara Petranovic, Tahrima Kayes, Audrey Z. Fu, Matthew Hoare

    Pulmonary function tests (PFTs) are performed ahead of listing for liver transplantation (LT) to assess respiratory fitness for transplantation. We aimed to establish whether pre-transplant PFTs were associated with post-LT overall survival and respiratory cause of death. A single-center retrospective study of patients transplanted between 2014 and 2023 was performed. Cox regression was used to analyze the relationship between PFT parameters, normalized for age, sex, ethnicity, and overall post-transplant survival. Competing risks regression was used to analyze the relationship between PFT parameters and respiratory death post-LT. Pre-transplant PFTs from 772 LT recipients were studied (33% female, median age 58 y, indication for transplant: alcohol-associated liver disease in 28.3%, metabolic dysfunction–associated steatotic liver disease in 18.0%). When combined with clinical variables, PFT parameters were predictive of post-transplant overall survival and respiratory death. Lower forced expiratory volume in 1 second (FEV1) (aHR 0.85, 95% CI 0.73–0.99, p =0.04), increased age at transplant (aHR 1.03, 95% CI 1.01–1.05, p =0.01), and current smoking at time of assessment (aHR 1.95, 95% CI 1.08–3.54, p =0.03) were independently associated with poorer post-transplant survival. Whereas both single-breath diffusing capacity of the lung (DLCO SB) (aSHR 0.66, 95% CI 0.52–0.82, p p =0.001) were independent predictors of post-LT respiratory cause of death. In conclusion, a lower FEV1 z -score was independently associated with poorer post-LT overall survival, and a lower DLCO SB z -score was associated with respiratory cause of death post-LT, supporting the routine use of PFTs in pre-liver transplant assessment.

  • Open Access

    Impact of breathing frequency on respiratory oscillometry measurements: a randomised cross-over and observational study of asthma patients

    by Ben Knox-Brown, Olga Carozzo, Karl P Sylvester

    Introduction: The impact of breathing frequency on respiratory oscillometry measurements is unknown. We aimed to investigate the impact of different breathing frequencies in patients with asthma. Method: We recruited patients from the severe asthma clinic at Cambridge University Hospitals. Using a randomised-crossover design, participants performed the forced oscillation technique at three different breathing frequencies (15, 30, 40 bpm) in a randomised order for each participant. A metronome was used to ensure the correct breathing frequency. Analysis of variance (ANOVA) and Friedman tests were utilised to assess the significance of any differences across the breathing frequencies. We then leveraged cross-sectional data from asthma patients who performed respiratory oscillometry and investigated the determinants of self-selected breathing frequency using multivariable linear regression. Results: We recruited 59 patients. Mean age 54.1 years, 58% female, median forced expiratory volume in 1 s (FEV 1 )/FVC z-score −2.56 (−3.26 to −1.96). As breathing frequency increased from 15 bpm to 40 bpm, there was a significant reduction (−8.6%, p<0.001) in total airway resistance (Rrs at 5 Hz), which was not mediated by changes in tidal volume or flow rate. There was also a significant reduction (−14.9%, p<0.001) in Delta R5–R19, and an increase (+10.9%, p=0.081) in reactance (Xrs at 5 Hz). At higher breathing frequencies, 5% of study participants were reclassified as having respiratory oscillometry measurements within normal limits. Data from 796 asthma patients were extracted for the cross-sectional analysis. The median (range) self-selected breathing frequency was 16.55 bpm (8.0, 42.0). Demographic data and lung function explained 23.5% of the variation in breathing frequency. Conclusion: Higher breathing frequencies significantly reduce total Rrs . When performing respiratory oscillometry, breathing frequency should be controlled at approximately 15 bpm to reduce risk of misclassification.

  • Open Access

    Physiological quotients and mortality: redefining lung function interpretation beyond FEV 1

    by Ben Knox-Brown, Lucy Robertson, Andre F.S. Amaral, Karl P. Sylvester

    Background: Forced expiratory volume in 1 s quotient (FEV 1 Q) is a physiological quotient reflecting the distance a measured FEV 1 is from a 1st percentile (minimally survivable) value. We aimed to derive physiological quotients for other lung function measures and assess their association with all-cause mortality. Methods: We analysed data from adults referred for lung function testing at Cambridge University Hospital (CUH) and Royal Papworth Hospital (RPH) in the UK between 2016 and 2024. We investigated the stability of the 1st percentiles for FEV 1 , forced vital capacity (FVC), FEV 1 /FVC, diffusing capacity of the lung for carbon monoxide ( D LCO ), transfer coefficient of the lung for carbon monoxide ( K CO ), alveolar volume ( V A ) and total lung capacity (TLC) stratified by sex and age group by visualising the overlap of 95% confidence intervals. We calculated physiological quotients for each parameter (Q=measured value/1st percentile value) and investigated their association with all-cause mortality using Cox regression analysis. We used Harrell's C-index to compare discriminative performance. Results: We analysed data from 7717 CUH patients and 6054 RPH patients. At CUH, 51% were female compared with 45% at RPH. Mean± sd age was 57.9±14.9 years at CUH and 62.7±14.8 years at RPH. 1st percentile values were generally consistent across age groups but different for males and females for FEV 1 , FVC, V A and TLC. For FEV 1 /FVC, D LCO and K CO , 1st percentile values were generally stable across both age and sex. Mean± sd follow-up times were 5.8±2.6 years at CUH and 5.5±2.7 years at RPH, during which time 19% and 39% of patients died, respectively. Physiological quotients had higher Harrell's C-indexes, indicating better discrimination of survival than lung function expressed as raw units, z-scores and percent predicted. Conclusion: Physiological quotients have greater discriminative ability in the prediction of all-cause mortality than existing metrics, providing an alternative standard for lung function interpretation.