Analysis of optical density and contrast in mammograms.
Authors:
- S MeesonSMS Meeson
- K C YoungKYK C Young
- M L RamsdaleMRM L Ramsdale
- M G WallisMWM G Wallis
- J CookeJCJ Cooke
- 1 July 1999
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 72 (859) , 670-677
Abstract
The objective of this project is the development of tools for the UK NHSBSP to assess image quality quantitatively in clinical films, for the purposes of optimizing imaging procedures and audit. As an initial step, 120 mammograms of 46 women on a single day of screening were digitized and analysed to produce indices of optical density (OD) and contrast. Analysis was performed on three regions of interest (ROI): pectoral muscle, main breast and skin edge. Two radiologists independently graded the quality of information in the different parts of each mammogram, and categorized breast type as either "dense", "mixed density" or "fatty". Measurements of contrast and OD generally correlated well with the opinions of the radiologists. For the oblique mammograms, the mean OD in the main breast ranged between films from 1.25 to 2.24 with a mean of 1.69 +/- 0.02. In the craniocaudal mammograms, the mean OD in the main breast ROI ranged from 1.14 to 1.94 with a mean of 1.61 +/- 0.05. The OD for a quality control film of a 40 mm block of PMMA exposed on the same day with this system was 1.53. A contrast index (CI) was calculated for each mammogram as the difference between the points of maximum and minimum OD in the main breast. Mean CI was 1.02 +/- 0.09 for fatty breasts, 1.50 +/- 0.10 for mixed density breasts and 2.05 +/- 0.23 for dense breasts. A review of the radiologist assessments indicated that the main breast was satisfactorily displayed when glandular and fatty tissues were displayed within the OD range 0.8-2.9. An analysis of the dynamic range requirements showed that 17% of films had a dynamic range that lay above that calculated using the suggested OD limits.Keywords
This publication has 9 references indexed in Scilit:
- Evaluation of an anatomical filter-based exposure equalization technique in mammography.British Journal of Radiology, 1998
- Estimation of compressed breast thickness during mammography.British Journal of Radiology, 1998
- Effect of automatic kV selection on dose and contrast for a mammographic X-ray system.British Journal of Radiology, 1997
- Thickness-equalization processing for mammographic images.Radiology, 1997
- Influence of number of views and mammographic film density on the detection of invasive cancers: results from the NHS Breast Screening Programme.British Journal of Radiology, 1997
- Dose and image quality in mammography with an automatic beam quality systemBritish Journal of Radiology, 1996
- Measurements of the frequency distribution of optical density in screening mammographyBritish Journal of Radiology, 1994
- Mammographic film density and detection of small breast cancersClinical Radiology, 1994
- Fitting the Photographic Characteristic Curve: A Functional Equation ApproachThe Journal of Photographic Science, 1993