Evaluating the Energy Conservation Effects of Implementing Automatic Voltage Regulator: A Case Study of Department Stores
Open Access
Abstract
Commercial buildings and shopping malls face rising electricity costs and increasing pressure to adopt sustainable practices. This paper presents the first long-term, multi-site empirical validation of Automatic Voltage Regulator (AVR) deployment in Thai retail facilities, providing robust evidence for tropical, motor-heavy load contexts. The study evaluates the engineering, economic, and environmental performance of an AVR with an autotransformer core under real operating conditions. High-resolution measurements were collected before and after AVR installation, using Class 0.2s analyzers and a Building Energy Management System (BEMS) across multiple branches during a four-month monitoring campaign (February–May). Results indicate that a modest voltage reduction of 8.06% yielded a 12.02% decrease in active power demand, a 6.22% current reduction, and a 2.26% improvement in power factor. The greatest savings occurred in HVAC (8.19%) and refrigeration loads (8.20%), while lighting loads remained nearly unchanged. Economically, the system delivered ~177 kWh/day savings, equivalent to 262,212 THB/year, with a simple payback of 2.67 years and an ROI of 37.5%. Environmentally, the AVR reduced 36.6 tCO2/year (±5%), aligning with Thailand’s Energy Efficiency Plan (EEP) 2018–2037 and Carbon Neutrality Roadmap and offering additional potential for T-VER monetization. These findings confirm AVR technology as a scalable, standards-compliant, and high-return retrofit solution for commercial facilities in tropical climates.Keywords
Funding Information
- Mahasarakham University
This publication has 23 references indexed in Scilit:
- Optimal decentralized coordination of electric vehicle aggregators, energy storage systems, and distributed generation in distribution networksElectric Power Systems Research, 2025
- A distributed double-layer control algorithm for medium voltage regulation and state of charge consensus of autonomous battery energy storage systems in distribution networksJournal of Energy Storage, 2024
- A promising ZnO/Graphene van der Waals heterojunction as solar cell devices: A first-principles studyEnergy Reports, 2022
- A market feedback framework for improved estimates of the arbitrage value of energy storage using price-taker modelsApplied Energy, 2022
- Thermal applications in vehicles using Hydralloy C5 in single and coupled metal hydride systemsApplied Energy, 2021
- Application of an unconventional thermal and mechanical energy storage coupled with the air conditioning and domestic hot water systems of a residential buildingEnergy and Buildings, 2020
- A new approach for the application of nearly zero energy concept at district level to reach EPBD recast requirements through a case study in TurkeyEnergy and Buildings, 2017
- Comparison of real-world fuel economy and emissions from parallel hybrid and conventional diesel buses fitted with selective catalytic reduction systemsApplied Energy, 2015
- Heat transfer characteristics of a molten-salt thermal energy storage unit with and without heat transfer enhancementApplied Energy, 2015
- Optimal operation strategy of the hybrid heating system composed of centrifugal heat pumps and gas boilersEnergy and Buildings, 2013