Narongkorn Uthathip
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Narongkorn Uthathip has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Montree Utakrue
Faculty of Engineering, Mahasarakham University, Maha Sarakham 44150, Thailand
1 shared publication - Nattawoot Suwannata
Faculty of Engineering, Mahasarakham University, Maha Sarakham 44150, Thailand
1 shared publication - Nuttapon Chaiduangsri
Department of Electrical Engineering, Faculty of Engineering, Mahasarakham University, Maha Sarakham 44150, Thailand
1 shared publication Pornrapeepat Bhasaputra
1 shared publication- Pornrapeepat Bhasaputra
Department of Electrical and Computer Engineering, Thammasat School of Engineering, Thammasat University, Pathum Thani 12120, Thailand
1 shared publication - Sitthisak Audomsi
Faculty of Engineering, Mahasarakham University, Maha Sarakham 44150, Thailand
1 shared publication
Latest Publications
- Open Access
Evaluating the Energy Conservation Effects of Implementing Automatic Voltage Regulator: A Case Study of Department Stores
Commercial buildings and shopping malls face rising electricity costs and increasing pressure to adopt sustainable practices. This paper presents the first long-term, multi-site empirical validation of Automatic Voltage Regulator (AVR) deployment in Thai retail facilities, providing robust evidence for tropical, motor-heavy load contexts. The study evaluates the engineering, economic, and environmental performance of an AVR with an autotransformer core under real operating conditions. High-resolution measurements were collected before and after AVR installation, using Class 0.2s analyzers and a Building Energy Management System (BEMS) across multiple branches during a four-month monitoring campaign (February–May). Results indicate that a modest voltage reduction of 8.06% yielded a 12.02% decrease in active power demand, a 6.22% current reduction, and a 2.26% improvement in power factor. The greatest savings occurred in HVAC (8.19%) and refrigeration loads (8.20%), while lighting loads remained nearly unchanged. Economically, the system delivered ~177 kWh/day savings, equivalent to 262,212 THB/year, with a simple payback of 2.67 years and an ROI of 37.5%. Environmentally, the AVR reduced 36.6 tCO2/year (±5%), aligning with Thailand’s Energy Efficiency Plan (EEP) 2018–2037 and Carbon Neutrality Roadmap and offering additional potential for T-VER monetization. These findings confirm AVR technology as a scalable, standards-compliant, and high-return retrofit solution for commercial facilities in tropical climates.
Open AccessEvaluating the Energy Conservation Effects of Implementing Automatic Voltage Regulator: A Case Study of Department Stores
Commercial buildings and shopping malls face rising electricity costs and increasing pressure to adopt sustainable practices. This paper presents the first long-term, multi-site empirical validation of Automatic Voltage Regulator (AVR) deployment in Thai retail facilities, providing robust evidence for tropical, motor-heavy load contexts. The study evaluates the engineering, economic, and environmental performance of an AVR with an autotransformer core under real operating conditions. High-resolution measurements were collected before and after AVR installation, using Class 0.2s analyzers and a Building Energy Management System (BEMS) across multiple branches during a four-month monitoring campaign (February–May). Results indicate that a modest voltage reduction of 8.06% yielded a 12.02% decrease in active power demand, a 6.22% current reduction, and a 2.26% improvement in power factor. The greatest savings occurred in HVAC (8.19%) and refrigeration loads (8.20%), while lighting loads remained nearly unchanged. Economically, the system delivered ~177 kWh/day savings, equivalent to 262,212 THB/year, with a simple payback of 2.67 years and an ROI of 37.5%. Environmentally, the AVR reduced 36.6 tCO2/year (±5%), aligning with Thailand’s Energy Efficiency Plan (EEP) 2018–2037 and Carbon Neutrality Roadmap and offering additional potential for T-VER monetization. These findings confirm AVR technology as a scalable, standards-compliant, and high-return retrofit solution for commercial facilities in tropical climates.
- Open Access
Development and Design of an Optimal Fuzzy Logic Two Degrees of Freedom-Proportional Integral Derivative Controller for a Two-Area Power System Using the Bee Algorithm
This study introduces a fuzzy logic-based two-degree-of-freedom PID (FL2DOF-PID) controller that is optimized using the Bee Algorithm (BA) to control the load frequency in a two-area linked power system that has both reheat thermal power plants and hydro power plants. To test how well it works, MATLAB/Simulink simulations compared it with PID, 2DOF-PID and fuzzy PID controllers, looking at overshoot, undershoot, settling time, steady-state error and the integral of absolute error (IAE). The results showed that FL2DOF-PID had the lowest RMSE (0.0054, 0.0089) and MAE (0.0041, 0.0065), as well as the smallest IAE (0.1308) and the smallest overshoot (69.3% less). It also had the fastest settling time (5.1528 s) and the smallest IAE (0.1338 less). These results showed that it works to reduce frequency changes, improve power flow stability and make the whole system more reliable under changing conditions.
Open AccessDevelopment and Design of an Optimal Fuzzy Logic Two Degrees of Freedom-Proportional Integral Derivative Controller for a Two-Area Power System Using the Bee Algorithm
This study introduces a fuzzy logic-based two-degree-of-freedom PID (FL2DOF-PID) controller that is optimized using the Bee Algorithm (BA) to control the load frequency in a two-area linked power system that has both reheat thermal power plants and hydro power plants. To test how well it works, MATLAB/Simulink simulations compared it with PID, 2DOF-PID and fuzzy PID controllers, looking at overshoot, undershoot, settling time, steady-state error and the integral of absolute error (IAE). The results showed that FL2DOF-PID had the lowest RMSE (0.0054, 0.0089) and MAE (0.0041, 0.0065), as well as the smallest IAE (0.1308) and the smallest overshoot (69.3% less). It also had the fastest settling time (5.1528 s) and the smallest IAE (0.1338 less). These results showed that it works to reduce frequency changes, improve power flow stability and make the whole system more reliable under changing conditions.
- Open Access
- 1 January 2022
- Published by Tech Science Press in Computer Systems Science and Engineering
- Vol. 42 (1) , 69-86
Application of ANFIS Model for Thailand’s Electric Vehicle Consumption
Generally, road transport is a major energy-consuming sector. Fuel consumption of each vehicle is an important factor that affects the overall energy consumption, driving behavior and vehicle characteristic are the main factors affecting the change of vehicle fuel consumption. It is difficult to analyze the influence of fuel consumption with multiple and complex factors. The Adaptive Neuro-Fuzzy Inference System (ANFIS) approach was employed to develop a vehicle fuel consumption model based on multivariate input. The ANFIS network was constructed by various experiments based on the ANFIS Parameter setting. The performance of the ANFIS network was validated using Root Mean Square Error (RMSE) and Mean Average Error (MAE) which related to the setting of ANFIS parameters. The experimental results indicated that the training data sample, number, and type of membership functions are the most important factor affecting the performance of the ANFIS network. However, the number of epochs does not necessarily significantly improve the system performance, too many the number of epochs setting may not provide the best results and lead to excessive responding time. The results also demonstrate that three factors, consisted of the engine size, driving speed, and the number of passengers, are important factors that influence the change of vehicle fuel consumption. The selected ANFIS models with minimum error can be properly and efficiently used to predict vehicle fuel consumption for Thailand’s road transport sector.
- 1 January 2022
- Published by Tech Science Press in Computer Systems Science and Engineering
- Vol. 42 (1) , 69-86
Open AccessApplication of ANFIS Model for Thailand’s Electric Vehicle Consumption
Generally, road transport is a major energy-consuming sector. Fuel consumption of each vehicle is an important factor that affects the overall energy consumption, driving behavior and vehicle characteristic are the main factors affecting the change of vehicle fuel consumption. It is difficult to analyze the influence of fuel consumption with multiple and complex factors. The Adaptive Neuro-Fuzzy Inference System (ANFIS) approach was employed to develop a vehicle fuel consumption model based on multivariate input. The ANFIS network was constructed by various experiments based on the ANFIS Parameter setting. The performance of the ANFIS network was validated using Root Mean Square Error (RMSE) and Mean Average Error (MAE) which related to the setting of ANFIS parameters. The experimental results indicated that the training data sample, number, and type of membership functions are the most important factor affecting the performance of the ANFIS network. However, the number of epochs does not necessarily significantly improve the system performance, too many the number of epochs setting may not provide the best results and lead to excessive responding time. The results also demonstrate that three factors, consisted of the engine size, driving speed, and the number of passengers, are important factors that influence the change of vehicle fuel consumption. The selected ANFIS models with minimum error can be properly and efficiently used to predict vehicle fuel consumption for Thailand’s road transport sector.
- Open Access
Stochastic Modelling to Analyze the Impact of Electric Vehicle Penetration in Thailand
Electric Vehicle (EV) technology is one of the most promising solutions to reduce dependence on fossil fuels and greenhouse gas (GHG) emissions in the transportation sector. However, a large increase of EVs raises concerns about negative impacts on electricity generation, transmission, and distribution systems. This study analyzes the benefits and trade-offs for EV penetration in Thai road transport based on EV penetration scenarios from 2019 to 2036. Two charging strategies are considered to assess the impact of EV charging: free charging and off-peak charging. Uncertainty variables are considered by a stochastic approach based on Monte-Carlo simulation (MCS). The simulation results shown that the adoption of EVs can reduce both energy consumption and GHG emissions. The results also indicate that the increased load due to EV charging demand in all scenarios is still within the buffer level, compared to the installed generation capacity in the Power Development Plan 2018 revision 1 (PDP2018r1), and the off-peak charging strategy is more beneficial than the free-charging strategy. However, the increased load demand caused by all EV charging strategies has a direct impact on the power generating schedule, and also decreases the system reliability level.
Open AccessStochastic Modelling to Analyze the Impact of Electric Vehicle Penetration in Thailand
Electric Vehicle (EV) technology is one of the most promising solutions to reduce dependence on fossil fuels and greenhouse gas (GHG) emissions in the transportation sector. However, a large increase of EVs raises concerns about negative impacts on electricity generation, transmission, and distribution systems. This study analyzes the benefits and trade-offs for EV penetration in Thai road transport based on EV penetration scenarios from 2019 to 2036. Two charging strategies are considered to assess the impact of EV charging: free charging and off-peak charging. Uncertainty variables are considered by a stochastic approach based on Monte-Carlo simulation (MCS). The simulation results shown that the adoption of EVs can reduce both energy consumption and GHG emissions. The results also indicate that the increased load due to EV charging demand in all scenarios is still within the buffer level, compared to the installed generation capacity in the Power Development Plan 2018 revision 1 (PDP2018r1), and the off-peak charging strategy is more beneficial than the free-charging strategy. However, the increased load demand caused by all EV charging strategies has a direct impact on the power generating schedule, and also decreases the system reliability level.