Reduced Data Acquisition Methods in Cardiac Imaging
Authors:
- Sebastian KozerkeSKSebastian Kozerke
- Jeffrey TsaoJTJeffrey Tsao
- 1 June 2004
- journal article
- review article
- Published by Wolters Kluwer Health in Topics in Magnetic Resonance Imaging
- Vol. 15 (3) , 161-168
Abstract
In cardiac imaging, acquisition speed is of primary importance. While improved performance has mainly been achieved through improvements in gradient hardware in the past, further developments along this direction are limited due to physiological constraints such as the risk of peripheral nerve stimulation. With the introduction of parallel imaging, alternative means for increasing acquisition speed have become available. Using information from multiple receiver coils, images can be reconstructed from a sparsely sampled set of data. In practice, parallel imaging allows for 2- to 3-fold acceleration of the imaging process in typical cardiac applications. Further increases in acquisition speed are, however, difficult to achieve for current clinical field strengths and typical field of views. To address the limited gain in acquisition speed achievable with parallel imaging, a new set of methods has been proposed to take into account the similarity of image information at different time points during a dynamic series. Using these methods, 5- to 8-fold acceleration can be achieved in cardiac imaging. It is the purpose of this paper to review cardiac applications of reduced data acquisition methods with focus on parallel imaging and the recently developed k-t BLAST and k-t SENSE techniques.Keywords
This publication has 41 references indexed in Scilit:
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Unifying linear prior‐information‐driven methods for accelerated image acquisitionMagnetic Resonance in Medicine, 2001
- Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)Magnetic Resonance in Medicine, 2000
- A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRIMagnetic Resonance in Medicine, 2000
- Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRIMagnetic Resonance in Medicine, 1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- AUTO-SMASH: A self-calibrating technique for SMASH imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Fast imaging using subencoding data sets from multiple detectorsMagnetic Resonance in Medicine, 1993
- Imaging time reduction through multiple receiver coil data acquisition and image reconstructionMagnetic Resonance in Medicine, 1993