UNTOWARD OUTCOMES IN 25-GAUGE VERSUS 20-GAUGE VITREORETINAL SURGERY
Authors:
- Son HoSHSon Ho
- Preston P. RichmondPRPreston P. Richmond
- John C. OlsonJOJohn C. Olson
- C Durham BarnesCBC Durham Barnes
- 1 October 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 27 (8) , 1048-1053
Abstract
This study compares the incidence of complications in eyes undergoing 25-gauge versus 20-gauge vitreoretinal procedures. Retrospective case series. A chart review of consecutive patients who underwent primary 25-gauge (129 eyes) and 20-gauge (129 eyes) vitreoretinal surgery by four surgeons at a single center between September 2002 and November 2005 was conducted. Mean follow-up was 9.1 +/- 4.9 months in 25-gauge eyes and 14.3 +/- 8.4 months in 20-gauge eyes (P < 0.01). Intraoperative complications were mainly rhegmatogenous in nature and occurred at statistically similar incidence (4.7% in 25-gauge eyes, 6.9% in 20-gauge eyes). Postoperative complications that were significantly associated with surgical method included hypotony and serous choroidal effusions (7.9% in 25-gauge eyes, 1.6% in 20-gauge eyes, P = 0.02). Other postoperative complications noted included retinal tears and detachments (5.4% in 25-gauge eyes, 4.7% in 20-gauge eyes), persistent vitreous hemorrhage (5.4% in each group), and new vitreous hemorrhage (3.9% in 25-gauge eyes, 0.8% in 20-gauge eyes). Endophthalmitis was noted only in 25-gauge eyes in 2 cases (1.6%). Cataract progression occurred at similar rates in both groups (46%). 25-gauge surgery is associated with a significantly greater incidence of postoperative serous choroidal effusions and hypotony. Of particular concern in 25-gauge surgery is the increased risk of associated endophthalmitis. Operative indications and case selection may be important in minimizing the tendency toward certain postoperative events.Keywords
This publication has 13 references indexed in Scilit:
- Ultrasound biomicroscopy findings of 25 G Transconjuctival sutureless (TSV) and conventional (20G) pars plana sclerotomy in the same patientBMC Ophthalmology, 2006
- 25-Gauge Transconjunctival Sutureless Pars Plana VitrectomyEuropean Journal of Ophthalmology, 2006
- Expanded Indications for 25-Gauge Transconjunctival VitrectomyJapanese Journal of Ophthalmology, 2005
- Comparison of clear corneal phacoemulsification combined with 25-gauge transconjunctival sutureless vitrectomy and standard 20-gauge vitrectomy for patients with cataract and vitreoretinal diseasesJournal of Cataract & Refractive Surgery, 2005
- Outcomes of 140 Consecutive Cases of 25-Gauge Transconjunctival Surgery for Posterior Segment DiseaseOphthalmology, 2005
- Endophthalmitis following 25-gauge vitrectomyEye, 2004
- Choroidal folds after 25 gauge transconjunctival sutureless vitrectomyEye, 2004
- Expression of the Functional Glucocorticoid Receptor in Mouse and Human Lens Epithelial CellsInvestigative Ophthalmology & Visual Science, 2003
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002