3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.Keywords
This publication has 43 references indexed in Scilit:
- Deviations of different systems for guided implant surgeryClinical Oral Implants Research, 2016
- Registration of cone beam computed tomography data and intraoral surface scans – A prerequisite for guided implant surgery with CAD/CAM drilling guidesClinical Oral Implants Research, 2016
- Distinguishing predictive profiles for patient‐based risk assessment and diagnostics of plaque induced, surgically and prosthetically triggered peri‐implantitisClinical Oral Implants Research, 2015
- Accuracy of Three‐Dimensional Printed Templates for Guided Implant Placement Based on Matching a Surface Scan with CBCTClinical Implant Dentistry and Related Research, 2015
- Accuracy of computer-aided design/computer-aided manufacturing–generated dental casts based on intraoral scanner dataThe Journal of the American Dental Association, 2014
- Esthetic Outcomes Following Immediate and Early Implant Placement in the Anterior Maxilla—A Systematic ReviewThe International Journal of Oral and Maxillofacial Implants, 2014
- [Template guided surgery with the open-access software "smop"].2014
- The intrinsic error of a stereolithographic surgical template in implant guided surgeryInternational Journal of Oral and Maxillofacial Surgery, 2013
- Factors influencing transfer accuracy of cone beam CT‐derived template‐based implant placementClinical Oral Implants Research, 2011
- Discovery of Lignin in Seaweed Reveals Convergent Evolution of Cell-Wall ArchitectureCurrent Biology, 2009