RNRobert Nicic

Robert Nicic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Nicic has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Florian Beuer

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany

    4 shared publications
  • Franziska Schmidt

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany

    4 shared publications
  • Elisabeth Prause

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany

    3 shared publications
  • Alexey Unkovskiy

    Department of Oral Surgery, E.V. Borovsky Institute of Dentistry, Sechenov First Moscow State Medical University, Moscow, 119048, Russia.

    2 shared publications
  • Jamila Yassine

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4–6, 14197 Berlin, Germany

    2 shared publications
  • Wolfgang B. Hannak

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany

    2 shared publications

Latest Publications

  • Open Access

    Biaxial Flexural Strength and Fracture Behavior of Five-Unit Monolithic Zirconia Fixed Dental Prostheses: An Experimental and Finite Element Study

    by Theresa Schwab, Jamila Yassine, Robert Nicic, Felix Borges, Alexander Pugachev, Franziska Schmidt

    Higher-translucency zirconia grades (4Y- and 5Y-PSZ) offer esthetic advantages over conventional 3Y-TZP but exhibit reduced flexural strength, raising concerns for restorations with reduced connector dimensions. It is unclear whether biaxial flexural strength, as determined by standardized specimen testing, translates to the fracture resistance of geometrically complex multi-unit bridges. This study compared the biaxial flexural strength (DIN EN ISO 6872:2015, n = 45) of three zirconia grades (3Y-TZP, 4Y-PSZ, and 5Y-PSZ) with the fracture behavior of monolithic five-unit fixed dental prostheses (FDPs) with deliberately undersized connectors (n = 24, teeth 33–37) made from the same three zirconia grades. Finite element (FE) analysis was used to compare the simulated elastic stress distribution with the experimentally observed fracture location. Biaxial flexural strength differed significantly among all groups (3Y-TZP: 1406.5 ± 133.3 MPa, 4Y-PSZ: 1146.9 ± 215.9 MPa, and 5Y-PSZ: 657.0 ± 137.5 MPa; p < 0.001). In contrast, bridge fracture loads differed less between the zirconia grades (3Y-TZP: 542.1 ± 44.9 N, 4Y-PSZ: 466.6 ± 116.6 N, and 5Y-PSZ: 372.1 ± 32.1 N). Only 5Y-PSZ showed significantly lower fracture loads than 3Y-TZP (p < 0.001), whereas 4Y-PSZ did not differ significantly from either 3Y-TZP (p = 0.253) or 5Y-PSZ (p = 0.129). All bridges initially fractured at the undersized connector, matching the site of the highest predicted tensile stress in den FE analysis. With this deliberately undersized connector, the differences in biaxial flexural strength between 3Y-TZP and 4Y-PSZ did not translate proportionally in a significant difference in fracture load. The FE analysis correctly identified the fracture-critical connector. The fracture load was not predicted, since the simulations were calibrated to the experimental fracture load values.

  • Open Access

    Clinical Performance and Patients’ Satisfaction of Digitally Versus Conventionally Fabricated Dentures: A Randomized Controlled Pilot Study

    by Jonas Rechlin, Florian Beuer, Robert Nicic, Rebecca Noetzel, Wolfgang Hannak, Elisabeth Prause

    Background/Objectives : Although digital workflows for complete denture fabrication are increasingly implemented in clinical practice, randomized controlled pilot trials directly comparing their clinical performance and patient satisfaction with conventional complete dentures (CCDs) remain scarce. This study aimed to compare patient satisfaction and clinical effectiveness between conventionally and digitally fabricated complete dentures (DCDs). Methods: In the present exploratory randomized controlled clinical pilot study using a cross-over design, 15 edentulous patients received both a conventionally fabricated and a digitally fabricated complete denture in randomized order. Each denture was worn for a three-month adaptation period. Patients were blinded to the fabrication method. Oral health-related quality of life was assessed using the OHIP-G49 questionnaire, and clinical performance was evaluated using standardized criteria at baseline, after three months with the first denture, and after three months with the second denture. Results: Both fabrication methods yielded satisfactory clinical outcomes in all patients. All 15 patients rated the DCDs as highly satisfactory, while 14 patients rated the CCDs equally favorably; one patient was unable to tolerate the conventional denture. DCDs demonstrated a slight but consistent advantage in oral health-related quality of life (OHRQoL) scores. Conclusions: Both conventional and digital complete dentures are clinically effective and well accepted by edentulous patients. However, DCDs offer a modest improvement in patient satisfaction and OHRQoL. Digitally fabricated complete dentures provide comparable clinical results to conventional methods while offering potential advantages in patient comfort and perceived quality of life. Given the exploratory nature of the study and the limited sample size, the results should be interpreted with caution and primarily serve to inform future, adequately powered randomized clinical trials.


  • Open Access

    Bending moments of PEEK-based root analog implants (RAIs)

    by Ufuk Adali, Felizia Kesler, Jamila Yassine, Franziska Schmidt, Mats Wernfried Heinrich Böse, Hui Zhu, Changning Sun, Chuncheng Yang, Dichen Li, Robert Nicic, et al.

  • Open Access

    The Effect of Build Angle and Artificial Aging on the Accuracy of SLA- and DLP-Printed Occlusal Devices

    by Bardia Saadat Sarmadi, Franziska Schmidt, Florian Beuer, Dilan Seda Metin, Philipp Simeon, Robert Nicic, Alexey Unkovskiy

    The aim of this study is to investigate the influence of printing material, build angle, and artificial aging on the accuracy of SLA- and DLP-printed occlusal devices in comparison to each other and to subtractively manufactured devices. A total of 192 occlusal devices were manufactured by one SLA-printing and two DLP-printing methods in 5 different build angles as well as milling. The specimens were scanned and superimposed to their initial CAD data and each other to obtain trueness and precision data values. A second series of scans were performed after the specimens underwent an artificial aging simulation by thermocycling. Again, trueness and precision were investigated, and pre- and post-aging values were compared. A statistically significant influence was found for all main effects: manufacturing method, build angle, and thermocycling, confirmed by two-way ANOVA. Regarding trueness, overall tendency indicated that subtractively manufactured splints were more accurate than the 3D-printed, with mean deviation values around ±0.15 mm, followed by the DLP1 group, with ±0.25 mm at 0 degree build angle. Within the additive manufacturing methods, DLP splints had significantly higher trueness for all build angles compared to SLA, which had the highest mean deviation values, with ±0.32 mm being the truest to the original CAD file. Regarding precision, subtractive manufacturing showed better accuracy than additive manufacturing. The artificial aging demonstrated a significant influence on the dimensional accuracy of only SLA-printed splints.


  • Open Access

    Visual Versus Digital Color Determination of 3D-Printed Teeth as an Exercise in Dental Students’ Education

    by Elisabeth Prause, Wolfgang B. Hannak, Robert Nicic, Holger A. Jakstat, Klaus Böning, Thomas Klinke

    Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann–Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.


  • Open Access

    The Assessability of Approximal Secondary Caries of Non-Invasive 3D-Printed Veneers Depending on the Restoration Thickness—An In Vitro Study

    by Elisabeth Prause, Jeremias Hey, Franziska Schmidt, Robert Nicic, Florian Beuer, Alexey Unkovskiy

    To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.5, 0.7, and 0.9 mm) were selected. After digital design, leaving the approximal space free, and manufacturing of the restorations, adhesive insertion followed. All specimens were placed in a demineralizing solution for 28 days. Subsequently, a radiological and fluorescent examination was performed. The present study showed statistically significant interactions for the day (p < 0.0001) and manufacturing method (p < 0.0001) but not for restoration thickness. Additive manufactured restorations showed less radiological caries progression compared to subtractive manufactured restorations after 21 and 28 days (0.7 and 0.9 mm restoration thickness) (p < 0.0001). DIAGNOdent proved that the restoration thickness affected the caries progression within the subtractive group (p < 0.0001). Radiographic and fluorescence examination showed equivalent results regarding approximal caries assessment. For additive manufacturing, less caries progression was shown without consideration of the restoration thickness.


  • Open Access

    How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?

    by Stefano Pieralli, Benedikt Christopher Spies, Valentin Hromadnik, Robert Nicic, Florian Beuer, Christian Wesemann

    3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.