Robert Nicic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert Nicic has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Florian Beuer
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
4 shared publications - Franziska Schmidt
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
4 shared publications - Elisabeth Prause
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
3 shared publications - Alexey Unkovskiy
Department of Oral Surgery, E.V. Borovsky Institute of Dentistry, Sechenov First Moscow State Medical University, Moscow, 119048, Russia.
2 shared publications - Jamila Yassine
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4–6, 14197 Berlin, Germany
2 shared publications - Wolfgang B. Hannak
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (10) , 529
Biaxial Flexural Strength and Fracture Behavior of Five-Unit Monolithic Zirconia Fixed Dental Prostheses: An Experimental and Finite Element Study
Higher-translucency zirconia grades (4Y- and 5Y-PSZ) offer esthetic advantages over conventional 3Y-TZP but exhibit reduced flexural strength, raising concerns for restorations with reduced connector dimensions. It is unclear whether biaxial flexural strength, as determined by standardized specimen testing, translates to the fracture resistance of geometrically complex multi-unit bridges. This study compared the biaxial flexural strength (DIN EN ISO 6872:2015, n = 45) of three zirconia grades (3Y-TZP, 4Y-PSZ, and 5Y-PSZ) with the fracture behavior of monolithic five-unit fixed dental prostheses (FDPs) with deliberately undersized connectors (n = 24, teeth 33–37) made from the same three zirconia grades. Finite element (FE) analysis was used to compare the simulated elastic stress distribution with the experimentally observed fracture location. Biaxial flexural strength differed significantly among all groups (3Y-TZP: 1406.5 ± 133.3 MPa, 4Y-PSZ: 1146.9 ± 215.9 MPa, and 5Y-PSZ: 657.0 ± 137.5 MPa; p < 0.001). In contrast, bridge fracture loads differed less between the zirconia grades (3Y-TZP: 542.1 ± 44.9 N, 4Y-PSZ: 466.6 ± 116.6 N, and 5Y-PSZ: 372.1 ± 32.1 N). Only 5Y-PSZ showed significantly lower fracture loads than 3Y-TZP (p < 0.001), whereas 4Y-PSZ did not differ significantly from either 3Y-TZP (p = 0.253) or 5Y-PSZ (p = 0.129). All bridges initially fractured at the undersized connector, matching the site of the highest predicted tensile stress in den FE analysis. With this deliberately undersized connector, the differences in biaxial flexural strength between 3Y-TZP and 4Y-PSZ did not translate proportionally in a significant difference in fracture load. The FE analysis correctly identified the fracture-critical connector. The fracture load was not predicted, since the simulations were calibrated to the experimental fracture load values.
- 19 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (10) , 529
Open AccessBiaxial Flexural Strength and Fracture Behavior of Five-Unit Monolithic Zirconia Fixed Dental Prostheses: An Experimental and Finite Element Study
Higher-translucency zirconia grades (4Y- and 5Y-PSZ) offer esthetic advantages over conventional 3Y-TZP but exhibit reduced flexural strength, raising concerns for restorations with reduced connector dimensions. It is unclear whether biaxial flexural strength, as determined by standardized specimen testing, translates to the fracture resistance of geometrically complex multi-unit bridges. This study compared the biaxial flexural strength (DIN EN ISO 6872:2015, n = 45) of three zirconia grades (3Y-TZP, 4Y-PSZ, and 5Y-PSZ) with the fracture behavior of monolithic five-unit fixed dental prostheses (FDPs) with deliberately undersized connectors (n = 24, teeth 33–37) made from the same three zirconia grades. Finite element (FE) analysis was used to compare the simulated elastic stress distribution with the experimentally observed fracture location. Biaxial flexural strength differed significantly among all groups (3Y-TZP: 1406.5 ± 133.3 MPa, 4Y-PSZ: 1146.9 ± 215.9 MPa, and 5Y-PSZ: 657.0 ± 137.5 MPa; p < 0.001). In contrast, bridge fracture loads differed less between the zirconia grades (3Y-TZP: 542.1 ± 44.9 N, 4Y-PSZ: 466.6 ± 116.6 N, and 5Y-PSZ: 372.1 ± 32.1 N). Only 5Y-PSZ showed significantly lower fracture loads than 3Y-TZP (p < 0.001), whereas 4Y-PSZ did not differ significantly from either 3Y-TZP (p = 0.253) or 5Y-PSZ (p = 0.129). All bridges initially fractured at the undersized connector, matching the site of the highest predicted tensile stress in den FE analysis. With this deliberately undersized connector, the differences in biaxial flexural strength between 3Y-TZP and 4Y-PSZ did not translate proportionally in a significant difference in fracture load. The FE analysis correctly identified the fracture-critical connector. The fracture load was not predicted, since the simulations were calibrated to the experimental fracture load values.
- Open Access
- 9 April 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (4) , 221
Clinical Performance and Patients’ Satisfaction of Digitally Versus Conventionally Fabricated Dentures: A Randomized Controlled Pilot Study
Background/Objectives : Although digital workflows for complete denture fabrication are increasingly implemented in clinical practice, randomized controlled pilot trials directly comparing their clinical performance and patient satisfaction with conventional complete dentures (CCDs) remain scarce. This study aimed to compare patient satisfaction and clinical effectiveness between conventionally and digitally fabricated complete dentures (DCDs). Methods: In the present exploratory randomized controlled clinical pilot study using a cross-over design, 15 edentulous patients received both a conventionally fabricated and a digitally fabricated complete denture in randomized order. Each denture was worn for a three-month adaptation period. Patients were blinded to the fabrication method. Oral health-related quality of life was assessed using the OHIP-G49 questionnaire, and clinical performance was evaluated using standardized criteria at baseline, after three months with the first denture, and after three months with the second denture. Results: Both fabrication methods yielded satisfactory clinical outcomes in all patients. All 15 patients rated the DCDs as highly satisfactory, while 14 patients rated the CCDs equally favorably; one patient was unable to tolerate the conventional denture. DCDs demonstrated a slight but consistent advantage in oral health-related quality of life (OHRQoL) scores. Conclusions: Both conventional and digital complete dentures are clinically effective and well accepted by edentulous patients. However, DCDs offer a modest improvement in patient satisfaction and OHRQoL. Digitally fabricated complete dentures provide comparable clinical results to conventional methods while offering potential advantages in patient comfort and perceived quality of life. Given the exploratory nature of the study and the limited sample size, the results should be interpreted with caution and primarily serve to inform future, adequately powered randomized clinical trials.
- 9 April 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (4) , 221
Open AccessClinical Performance and Patients’ Satisfaction of Digitally Versus Conventionally Fabricated Dentures: A Randomized Controlled Pilot Study
Background/Objectives : Although digital workflows for complete denture fabrication are increasingly implemented in clinical practice, randomized controlled pilot trials directly comparing their clinical performance and patient satisfaction with conventional complete dentures (CCDs) remain scarce. This study aimed to compare patient satisfaction and clinical effectiveness between conventionally and digitally fabricated complete dentures (DCDs). Methods: In the present exploratory randomized controlled clinical pilot study using a cross-over design, 15 edentulous patients received both a conventionally fabricated and a digitally fabricated complete denture in randomized order. Each denture was worn for a three-month adaptation period. Patients were blinded to the fabrication method. Oral health-related quality of life was assessed using the OHIP-G49 questionnaire, and clinical performance was evaluated using standardized criteria at baseline, after three months with the first denture, and after three months with the second denture. Results: Both fabrication methods yielded satisfactory clinical outcomes in all patients. All 15 patients rated the DCDs as highly satisfactory, while 14 patients rated the CCDs equally favorably; one patient was unable to tolerate the conventional denture. DCDs demonstrated a slight but consistent advantage in oral health-related quality of life (OHRQoL) scores. Conclusions: Both conventional and digital complete dentures are clinically effective and well accepted by edentulous patients. However, DCDs offer a modest improvement in patient satisfaction and OHRQoL. Digitally fabricated complete dentures provide comparable clinical results to conventional methods while offering potential advantages in patient comfort and perceived quality of life. Given the exploratory nature of the study and the limited sample size, the results should be interpreted with caution and primarily serve to inform future, adequately powered randomized clinical trials.
- Open Access
- 6 April 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 184, 112677
Bending moments of PEEK-based root analog implants (RAIs)
- 6 April 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 184, 112677
Open AccessBending moments of PEEK-based root analog implants (RAIs)
- Open Access
The Effect of Build Angle and Artificial Aging on the Accuracy of SLA- and DLP-Printed Occlusal Devices
The aim of this study is to investigate the influence of printing material, build angle, and artificial aging on the accuracy of SLA- and DLP-printed occlusal devices in comparison to each other and to subtractively manufactured devices. A total of 192 occlusal devices were manufactured by one SLA-printing and two DLP-printing methods in 5 different build angles as well as milling. The specimens were scanned and superimposed to their initial CAD data and each other to obtain trueness and precision data values. A second series of scans were performed after the specimens underwent an artificial aging simulation by thermocycling. Again, trueness and precision were investigated, and pre- and post-aging values were compared. A statistically significant influence was found for all main effects: manufacturing method, build angle, and thermocycling, confirmed by two-way ANOVA. Regarding trueness, overall tendency indicated that subtractively manufactured splints were more accurate than the 3D-printed, with mean deviation values around ±0.15 mm, followed by the DLP1 group, with ±0.25 mm at 0 degree build angle. Within the additive manufacturing methods, DLP splints had significantly higher trueness for all build angles compared to SLA, which had the highest mean deviation values, with ±0.32 mm being the truest to the original CAD file. Regarding precision, subtractive manufacturing showed better accuracy than additive manufacturing. The artificial aging demonstrated a significant influence on the dimensional accuracy of only SLA-printed splints.
Open AccessThe Effect of Build Angle and Artificial Aging on the Accuracy of SLA- and DLP-Printed Occlusal Devices
The aim of this study is to investigate the influence of printing material, build angle, and artificial aging on the accuracy of SLA- and DLP-printed occlusal devices in comparison to each other and to subtractively manufactured devices. A total of 192 occlusal devices were manufactured by one SLA-printing and two DLP-printing methods in 5 different build angles as well as milling. The specimens were scanned and superimposed to their initial CAD data and each other to obtain trueness and precision data values. A second series of scans were performed after the specimens underwent an artificial aging simulation by thermocycling. Again, trueness and precision were investigated, and pre- and post-aging values were compared. A statistically significant influence was found for all main effects: manufacturing method, build angle, and thermocycling, confirmed by two-way ANOVA. Regarding trueness, overall tendency indicated that subtractively manufactured splints were more accurate than the 3D-printed, with mean deviation values around ±0.15 mm, followed by the DLP1 group, with ±0.25 mm at 0 degree build angle. Within the additive manufacturing methods, DLP splints had significantly higher trueness for all build angles compared to SLA, which had the highest mean deviation values, with ±0.32 mm being the truest to the original CAD file. Regarding precision, subtractive manufacturing showed better accuracy than additive manufacturing. The artificial aging demonstrated a significant influence on the dimensional accuracy of only SLA-printed splints.
- Open Access
- 26 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 24
Visual Versus Digital Color Determination of 3D-Printed Teeth as an Exercise in Dental Students’ Education
Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann–Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.
- 26 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 24
Open AccessVisual Versus Digital Color Determination of 3D-Printed Teeth as an Exercise in Dental Students’ Education
Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann–Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.
- Open Access
- 22 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 992
The Assessability of Approximal Secondary Caries of Non-Invasive 3D-Printed Veneers Depending on the Restoration Thickness—An In Vitro Study
To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.5, 0.7, and 0.9 mm) were selected. After digital design, leaving the approximal space free, and manufacturing of the restorations, adhesive insertion followed. All specimens were placed in a demineralizing solution for 28 days. Subsequently, a radiological and fluorescent examination was performed. The present study showed statistically significant interactions for the day (p < 0.0001) and manufacturing method (p < 0.0001) but not for restoration thickness. Additive manufactured restorations showed less radiological caries progression compared to subtractive manufactured restorations after 21 and 28 days (0.7 and 0.9 mm restoration thickness) (p < 0.0001). DIAGNOdent proved that the restoration thickness affected the caries progression within the subtractive group (p < 0.0001). Radiographic and fluorescence examination showed equivalent results regarding approximal caries assessment. For additive manufacturing, less caries progression was shown without consideration of the restoration thickness.
- 22 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 992
Open AccessThe Assessability of Approximal Secondary Caries of Non-Invasive 3D-Printed Veneers Depending on the Restoration Thickness—An In Vitro Study
To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.5, 0.7, and 0.9 mm) were selected. After digital design, leaving the approximal space free, and manufacturing of the restorations, adhesive insertion followed. All specimens were placed in a demineralizing solution for 28 days. Subsequently, a radiological and fluorescent examination was performed. The present study showed statistically significant interactions for the day (p < 0.0001) and manufacturing method (p < 0.0001) but not for restoration thickness. Additive manufactured restorations showed less radiological caries progression compared to subtractive manufactured restorations after 21 and 28 days (0.7 and 0.9 mm restoration thickness) (p < 0.0001). DIAGNOdent proved that the restoration thickness affected the caries progression within the subtractive group (p < 0.0001). Radiographic and fluorescence examination showed equivalent results regarding approximal caries assessment. For additive manufacturing, less caries progression was shown without consideration of the restoration thickness.
- Open Access
- 22 July 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (8) , 2322
How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.
- 22 July 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (8) , 2322
Open AccessHow Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.