Abstract
We developed a new data collection system named i-converter that could transmit data to a website via cellular phone. Using the system, we compared the effects of two calcium channel blockers on the home blood pressure. Amlodipine and nifedipine CR were administered to 41 patients with essential hypertension for more than 6 weeks each in a randomized open-label crossover study. The dose of each drug was increased until the home blood pressure reached the target level of under 135/85 mmHg. The morning home systolic and diastolic blood pressures were significantly lower during nifedipine CR treatment: 133 ± 10/81 ± 8 mmHg with amlodipine versus 131 ± 8/80 ± 8 mmHg with nifedipine CR, P < 0.05. The morning pulse rate was significantly higher during nifedipine CR treatment (69 ± 9 beats/min with amlodipine versus 70 ± 9 beats/min with nifedipine CR, P < 0.05). The evening home blood pressure and pulse rate, however, showed no significant differences between the two drugs (128 ± 11/74 ± 7 mmHg and 74 ± 10 beats/min with amlodipine versus 128 ± 10/75 ± 7 mmHg and 74 ± 9 beats/min with nifedipine CR, all not significant). Nifedipine CR had a stronger antihypertensive effect than amlodipine during the critical morning period, but the morning pulse rate was higher. Our new data transmission system was effective for collecting precise data on the blood pressure and pulse rate via the internet.Keywords
This publication has 14 references indexed in Scilit:
- Efficacy of a home blood pressure monitoring programme on therapeutic compliance in hypertension: the EAPACUM–HTA studyJournal Of Hypertension, 2006
- Cardiovascular Prognosis of "Masked Hypertension" Detected by Blood Pressure Self-measurement in Elderly Treated Hypertensive PatientsJAMA, 2004
- 2003 World Health Organization (WHO)/International Society of Hypertension (ISH) statement on management of hypertensionJournal Of Hypertension, 2003
- 2003 European Society of Hypertension???European Society of Cardiology guidelines for the management of arterial hypertension*Journal Of Hypertension, 2003
- Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705ITBlood Pressure Monitoring, 2003
- The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureThe JNC 7 ReportJAMA, 2003
- Morning Surge in Blood Pressure as a Predictor of Silent and Clinical Cerebrovascular Disease in Elderly HypertensivesCirculation, 2003
- Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at HomeHypertension Research, 2003
- Predictive values of automated blood pressure measurement: what can we learn from the Japanese population – the Ohasama studyBlood Pressure Monitoring, 2001
- Formulation Design of Nifedipine Sustained-release Tablets (ADALAT CR Tablet) Based on Coat-core Technology of Hydrophilic-matrix.MEMBRANE, 2000