Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
Authors:
- 23 May 2012
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 29 (1) , 245-252
Abstract
To investigate the feasibility of contrast media (CM) volume reduction in dual-source coronary computed tomography angiography high-pitch mode without affecting coronary artery enhancement. Eighty patients were involved in a preliminary experiment with a default injection protocol (60 ml of CM). The age, BMI, test bolus (TB) enhancement peak and the CT values of coronary artery for each patient were recorded and the key factors for determining coronary artery enhancement were investigated. Based on the results of the preliminary experiment, 120 patients were involved in the main experiment with a new injection protocol. For each patient, the CT values and noise of left coronary sinus (LCS), and the distal segment of right coronary artery were measured. In the preliminary experiment, the peak enhancement of TB correlated most strongly with the HU values of coronary artery. Consequently, the new injection protocol was devised to catalog patients into four groups (30, 40, 50 and 60 ml) of CM based on their TB peak enhancement. In the main experiment, the 30 ml CM injection group whose peak attenuation of TB were the highest (30 vs. 40,50,60 ml: 323.0 ± 27.5 vs. 264.2 ± 11.9, 242.1 ± 8.8, 206.2 ± 18.2 HU, p < 0.05), obtained the highest attenuation of LCS (30 vs. 40,50,60 ml: 365.0 ± 41.2 vs. 341.8 ± 40.0, 326.9 ± 34.7, 312.5 ± 38.2 HU p < 0.05). Contrast optimization is feasible in high-pitch DSCT coronary angiography. Certain patients may receive 30 ml of CM without affecting vessel enhancement.Keywords
This publication has 26 references indexed in Scilit:
- Coronary Enhancement for Prospective ECG-Gated Single R-R Axial 320-MDCT Angiography: Comparison of 60- and 80-mL Iopamidol 370 InjectionAmerican Journal of Roentgenology, 2011
- Iodinated Contrast Opacification Gradients in Normal Coronary Arteries Imaged With Prospectively ECG-Gated Single Heart Beat 320-Detector Row Computed TomographyCirculation: Cardiovascular Imaging, 2010
- Hydrokinetic approach to large-scale cardiovascular blood flowComputer Physics Communications, 2010
- Prediction of coronary artery plaque progression and potential rupture from 320-detector row prospectively ECG-gated single heart beat CT angiography: Lattice Boltzmann evaluation of endothelial shear stressThe International Journal of Cardiovascular Imaging, 2009
- Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiographyThe International Journal of Cardiovascular Imaging, 2008
- Coronary Angiography by 64-Detector Row Computed Tomography Using Low Dose of Contrast Material with Saline ChaserJournal of Computer Assisted Tomography, 2007
- The clinical and renal consequences of contrast-induced nephropathyNephrology Dialysis Transplantation, 2006
- Contrast Bolus Optimization for Cardiac 16-Slice Computed TomographyInvestigative Radiology, 2006
- Development of Renal Disease in People at High Cardiovascular RiskJournal of the American Society of Nephrology, 2003
- Determination of Scan Delay Time in Spiral CT-AngiographyJournal of Computer Assisted Tomography, 1995