Coronary Angiography by 64-Detector Row Computed Tomography Using Low Dose of Contrast Material with Saline Chaser
Authors:
- Masaki YamamuroMYMasaki Yamamuro
- Eiji TadamuraETEiji Tadamura
- Shotaro KanaoSKShotaro Kanao
- Yen-Wen WuYWYen-Wen Wu
- Keiichi TambaraKTKeiichi Tambara
- Masashi KomedaMKMasashi Komeda
- Masanao TomaMTMasanao Toma
- Takeshi KimuraTKTakeshi Kimura
- Toru KitaTKToru Kita
- Kaori TogashiKTKaori Togashi
- 1 March 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 31 (2) , 272-280
Abstract
To assess the influence of total injection volume on thoracic great vessels and coronary arteries enhancement in 64-detecter row computed tomography (CT) coronary angiography using low dose of contrast material. Sixty patients underwent cardiac CT (64 × 0.5 mm, 0.4 rot/s) using 40 mL of contrast material (350 mg of Iodine per milliliter) in 30 patients and 50 mL in 30 patients. Computed tomography densities (Hounsfield units) in ascending aorta, descending aorta, and main pulmonary artery were measured at every second with the time of CT data acquisition recorded in each reconstructed image. Computed tomography densities of proximal and distal coronary arteries were also measured. Differences in CT densities between 40 and 50 mL contrast material were assessed with the Student t test. In addition, the relation between the injection volume (mL) of contrast material per kilogram body weight and contrast enhancement in coronary arteries was studied. The average attenuations in the ascending and descending aorta and coronary arteries were significantly lower in 40-mL group than in 50-mL group (<0.05). In addition, the average attenuations in the pulmonary artery were significantly lower in 40-mL group than 50-mL group (<0.01). Every patient with the total injection volume of more than 0.9 mL/kg body weight showed a contrast enhancement more than 250 Hounsfield units. The reduction of total injection volume lowered the enhancement of thoracic great vessels and coronary arteries in 64-detector row cardiac CT. The injection volume of at least 0.9 mL/kg body weight was necessary for a steady contrast enhancement in coronary arteries.Keywords
This publication has 24 references indexed in Scilit:
- Computed Tomography Coronary Angiography With 370-Millisecond Gantry Rotation TimeJournal of Computer Assisted Tomography, 2005
- Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation doseEuropean Radiology, 2004
- Intravenous Contrast Material Administration at 16–Detector Row Helical CT Coronary Angiography: Test Bolus versus Bolus-tracking TechniqueRadiology, 2004
- Detection of Calcified and Noncalcified Coronary Atherosclerotic Plaque by Contrast-Enhanced, Submillimeter Multidetector Spiral Computed TomographyCirculation, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patientsEuropean Heart Journal, 2002
- Parameters Affecting Bolus Geometry in CTA: A ReviewJournal of Computer Assisted Tomography, 2002
- Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed TomographyCirculation, 2001
- Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography11This study was performed without additional financial support.JACC, 2001
- Coronary angiography with multi-slice computed tomographyThe Lancet, 2001