Polyaxial Locking Plate Fixation in Distal Femur Fractures: A Biomechanical Comparison
Authors:
- Kenneth J WilkensKWKenneth J Wilkens
- Mark A LeeMLMark A Lee
- 1 October 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 22 (9) , 624-628
Abstract
Objectives: Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that of a new polyaxial design. Methods: A comminuted supracondylar femur fracture (AO/OTA33-A3) gap model was created in fourth-generation synthetic composite bones. Fixation was obtained with 2 different plate constructs: (1) a conventional locking plate (uniaxial screw heads threading directly into plate) and (2) a polyaxial locking plate (screw heads are captured and “locked” into a fixed angle using locking caps). Eight specimens of each type were then tested in axial, torsional, and cyclic axial modes on a material testing machine. Results: The mean axial stiffness for the polyaxial locking plate was 24.4% greater than the conventional locking plate (168.2 vs 127.1 N/mm; P < 0.0001). The mean torsional stiffness was also greater for the polyaxial plate (2.78 vs 2.57 Nm/degree; P = 0.0226). Cyclic axial loading caused significantly less (P = 0.0034) mean irreversible deformation in the polyaxial plate (5.6 mm) than in the conventional plate (8.8 mm). The mean ultimate load to failure was significantly higher (P = 0.0005) for the polyaxial plate (1560 N) than for the conventional plate (1337 N). Conclusions: The tested plate construct with its polyaxial locking screw mechanism provides a biomechanically sound fixation option for supracondylar femur fractures. The frictional locking mechanism allows maintenance of angular stability while affording the option of variable screw placement.Keywords
This publication has 18 references indexed in Scilit:
- Results of Polyaxial Locked-Plate Fixation of Periarticular Fractures of the KneeJournal of Bone and Joint Surgery, 2007
- Biomechanical Analysis of Distal Femur Fracture Fixation: Fixed-Angle Screw-Plate Construct Versus Condylar Blade PlateJournal of Orthopaedic Trauma, 2007
- The Effect of Plate Rotation on the Stiffness of Femoral LISS: A Mechanical StudyJournal of Orthopaedic Trauma, 2006
- Operative Treatment of Acute Distal Femur Fractures: Systematic Review of 2 Comparative Studies and 45 Case Series (1989 to 2005)Journal of Orthopaedic Trauma, 2006
- Biomechanical Evaluation of the Less Invasive Stabilization System, Angled Blade Plate, and Retrograde Intramedullary Nail for the Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2004
- Guidelines for the clinical application of the LCPInjury, 2003
- Supracondylar femur fracture fixation: Mechanical comparison of the 95° condylar side plate and screw versus 95° angled blade plateActa Orthopaedica, 2002
- Biomechanical Evaluation of the Less Invasive Stabilization System for the Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2001
- Biomechanical Analysis of Supracondylar Femoral Fractures Fixed With Modern Retrograde Intramedullary NailsJournal of Orthopaedic Trauma, 1999
- Distal Femoral Fixation: A Biomechanical Comparison of the Standard Condylar Buttress Plate, a Locked Buttress Plate, and the 95-Degree Blade PlateJournal of Orthopaedic Trauma, 1997