A Miniature Dual-Fiber Probe for Quantitative Optical Coherence Elastography
- 11 May 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (11) , 3064-3072
Abstract
Objective: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. Methods: We present a miniaturized dual-fiber OCE probe of $1 \,\mathrm{m}\mathrm{m}$ diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. Results: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of $0.15 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.02 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to $0.54 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.03 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. Conclusion: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. Significance: This study introduces an approach for robust elasticity quantification from within the tissue.Keywords
Funding Information
- German Research Foundation DFG (SCHL 1844/2-2)
- Technische Universität Hamburg
- Interdisciplinary Competence Center for Interface Research
- Universitätsklinikum Hamburg-Eppendorf
- Technische Universität Hamburg
This publication has 31 references indexed in Scilit:
- An Approach for Needle Based Optical Coherence Elastography Measurements2017
- Miniature probe for mapping mechanical properties of vascular lesions using acoustic radiation force optical coherence elastographyScientific Reports, 2017
- Magnetic resonance elastography (MRE) in cancer: Technique, analysis, and applicationsProgress in Nuclear Magnetic Resonance Spectroscopy, 2015
- WFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 1: Basic Principles and TerminologyUltrasound in Medicine & Biology, 2015
- Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samplesBiomedical Optics Express, 2014
- Needle optical coherence elastography for tissue boundary detectionOptics Letters, 2012
- On the effects of reflected waves in transient shear wave elastographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- US ArtifactsRadioGraphics, 2009
- An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissuesMeasurement Science and Technology, 2008
- An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approachIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995