Sarah Latus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sarah Latus has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Maximilian Neidhardt
Institute of Medical Technology and Intelligent Systems, Hamburg University of Technology
6 shared publications Alexander Schlaefer
Institute of Medical Technology and Intelligent Systems, Hamburg University of Technology, Hamburg, Germany
4 shared publications- Alexander Schlaefer
Hamburg University of Technology
4 shared publications - Sarah Grube
Hamburg University of Technology, Institute of Medical Technology and Intelligent Systems, Hamburg , Germany
3 shared publications - Stefan Gerlach
Institute of Medical Technology and Intelligent Systems, Hamburg University of Technology, Germany
3 shared publications Axel Heinemann
Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 108851-108865
An AI-Based Mobile Robot for Autonomous Ultrasound in Legal Medicine
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 108851-108865
Open AccessAn AI-Based Mobile Robot for Autonomous Ultrasound in Legal Medicine
- Open Access
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (3) , 1445-1453
Deep Learning for High Speed Optical Coherence Elastography With a Fiber Scanning Endoscope
Tissue stiffness is related to soft tissue pathologies and can be assessed through palpation or via clinical imaging systems, e.g., ultrasound or magnetic resonance imaging. Typically, the image based approaches are not suitable during interventions, particularly for minimally invasive surgery. To this end, we present a miniaturized fiber scanning endoscope for fast and localized elastography. Moreover, we propose a deep learning based signal processing pipeline to account for the intricate data and the need for real-time estimates. Our elasticity estimation approach is based on imaging complex and diffuse wave fields that encompass multiple wave frequencies and propagate in various directions. We optimize the probe design to enable different scan patterns. To maximize temporal sampling while maintaining three-dimensional information we define a scan pattern in a conical shape with a temporal frequency of 5.05 kHz. To efficiently process the image sequences of complex wave fields we consider a spatio-temporal deep learning network. We train the network in an end-to-end fashion on measurements from phantoms representing multiple elasticities. The network is used to obtain localized and robust elasticity estimates, allowing to create elasticity maps in real-time. For 2D scanning, our approach results in a mean absolute error of 6.31 ± 5.76 kPa compared to 11.33 ± 12.78 kPa for conventional phase tracking. For scanning without estimating the wave direction, the novel 3D method reduces the error to 4.48 ± 3.63 kPa compared to 19.75 ± 21.82 kPa for the conventional 2D method. Finally, we demonstrate feasibility of elasticity estimates in ex-vivo porcine tissue.
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (3) , 1445-1453
Open AccessDeep Learning for High Speed Optical Coherence Elastography With a Fiber Scanning Endoscope
Tissue stiffness is related to soft tissue pathologies and can be assessed through palpation or via clinical imaging systems, e.g., ultrasound or magnetic resonance imaging. Typically, the image based approaches are not suitable during interventions, particularly for minimally invasive surgery. To this end, we present a miniaturized fiber scanning endoscope for fast and localized elastography. Moreover, we propose a deep learning based signal processing pipeline to account for the intricate data and the need for real-time estimates. Our elasticity estimation approach is based on imaging complex and diffuse wave fields that encompass multiple wave frequencies and propagate in various directions. We optimize the probe design to enable different scan patterns. To maximize temporal sampling while maintaining three-dimensional information we define a scan pattern in a conical shape with a temporal frequency of 5.05 kHz. To efficiently process the image sequences of complex wave fields we consider a spatio-temporal deep learning network. We train the network in an end-to-end fashion on measurements from phantoms representing multiple elasticities. The network is used to obtain localized and robust elasticity estimates, allowing to create elasticity maps in real-time. For 2D scanning, our approach results in a mean absolute error of 6.31 ± 5.76 kPa compared to 11.33 ± 12.78 kPa for conventional phase tracking. For scanning without estimating the wave direction, the novel 3D method reduces the error to 4.48 ± 3.63 kPa compared to 19.75 ± 21.82 kPa for the conventional 2D method. Finally, we demonstrate feasibility of elasticity estimates in ex-vivo porcine tissue.
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (11) , 3064-3072
A Miniature Dual-Fiber Probe for Quantitative Optical Coherence Elastography
Objective: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. Methods: We present a miniaturized dual-fiber OCE probe of $1 \,\mathrm{m}\mathrm{m}$ diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. Results: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of $0.15 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.02 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to $0.54 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.03 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. Conclusion: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. Significance: This study introduces an approach for robust elasticity quantification from within the tissue.
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (11) , 3064-3072
A Miniature Dual-Fiber Probe for Quantitative Optical Coherence Elastography
Objective: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. Methods: We present a miniaturized dual-fiber OCE probe of $1 \,\mathrm{m}\mathrm{m}$ diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. Results: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of $0.15 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.02 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to $0.54 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.03 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. Conclusion: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. Significance: This study introduces an approach for robust elasticity quantification from within the tissue.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 491-495
Ultrasound shear wave velocity estimation in a small field of view via spatio-temporal deep learning
A change in tissue stiffness can indicate pathological diseases and therefore supports physicians in diagnosis and treatment. Ultrasound shear wave elastography (US-SWEI) can be used to quantify tissue stiffness by estimating the velocity of propagating shear waves. While a linear US probe with a lateral imaging width of approximately 40 mm is commonly used and US-SWEI has been successfully demonstrated, some clinical applications, such as laparoscopic or endoscopic interventions, require small probes. This limits the lateral image width to the millimeter range and reduces the available information in the US images substantially. In this work, we systematically analyze the effect of a reduced lateral imaging width for shear wave velocity estimation using the conventional time-of-flight (ToF) method and spatio-temporal convolutional neural networks (ST-CNNs). For our study, we use tissue mimicking gelatin phantoms with varying stiffness and resulting shear wave velocities in the range from 3.63 m/s to 7.09 m/s. We find that lateral imaging width has a substantial impact on the performance of ToF, while shear wave velocity estimation with ST-CNNs remains robust. Our results show that shear wave velocity estimation with ST-CNN can even be performed for a lateral imaging width of 2.1 mm resulting in a mean absolute error of 0.81 ± 0.61 m/s.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 491-495
Ultrasound shear wave velocity estimation in a small field of view via spatio-temporal deep learning
A change in tissue stiffness can indicate pathological diseases and therefore supports physicians in diagnosis and treatment. Ultrasound shear wave elastography (US-SWEI) can be used to quantify tissue stiffness by estimating the velocity of propagating shear waves. While a linear US probe with a lateral imaging width of approximately 40 mm is commonly used and US-SWEI has been successfully demonstrated, some clinical applications, such as laparoscopic or endoscopic interventions, require small probes. This limits the lateral image width to the millimeter range and reduces the available information in the US images substantially. In this work, we systematically analyze the effect of a reduced lateral imaging width for shear wave velocity estimation using the conventional time-of-flight (ToF) method and spatio-temporal convolutional neural networks (ST-CNNs). For our study, we use tissue mimicking gelatin phantoms with varying stiffness and resulting shear wave velocities in the range from 3.63 m/s to 7.09 m/s. We find that lateral imaging width has a substantial impact on the performance of ToF, while shear wave velocity estimation with ST-CNNs remains robust. Our results show that shear wave velocity estimation with ST-CNN can even be performed for a lateral imaging width of 2.1 mm resulting in a mean absolute error of 0.81 ± 0.61 m/s.
- Open Access
- 20 May 2022
- Published by Springer Nature
- p. 301-309
Proximity-Based Haptic Feedback for Collaborative Robotic Needle Insertion
Collaborative robotic needle insertions have the potential to improve placement accuracy and safety, e.g., during epidural anesthesia. Epidural anesthesia provides effective regional pain management but can lead to serious complications, such as nerve injury or cerebrospinal fluid leakage. Robotic assistance might prevent inadvertent puncture by providing haptic feedback to the physician. Haptic feedback can be realized on the basis of force measurements at the needle. However, contact should be avoided for delicate structures. We propose a proximity-based method to provide feedback prior to contact. We measure the distance to boundary layers, visualize the proximity for the operator and further feedback it as a haptic resistance. We compare our approach to haptic feedback based on needle forces and visual feedback without haptics. Participants are asked to realize needle insertions with each of the three feedback modes. We use phantoms that mimic the structures punctured during epidural anesthesia. We show that visual feedback improves needle placement, but only proximity-based haptic feedback reduces accidental puncture. The puncture rate is 62% for force-based haptic feedback, 60% for visual feedback and 6% for proximity-based haptic feedback. Final needle placement inside the epidural space is achieved in 38%, 70% and 96% for force-based haptic, visual and proximity-based haptic feedback, respectively. Our results suggest that proximity-based haptic feedback could improve needle placement safety in the context of epidural anesthesia.
- 20 May 2022
- Published by Springer Nature
- p. 301-309
Open AccessProximity-Based Haptic Feedback for Collaborative Robotic Needle Insertion
Collaborative robotic needle insertions have the potential to improve placement accuracy and safety, e.g., during epidural anesthesia. Epidural anesthesia provides effective regional pain management but can lead to serious complications, such as nerve injury or cerebrospinal fluid leakage. Robotic assistance might prevent inadvertent puncture by providing haptic feedback to the physician. Haptic feedback can be realized on the basis of force measurements at the needle. However, contact should be avoided for delicate structures. We propose a proximity-based method to provide feedback prior to contact. We measure the distance to boundary layers, visualize the proximity for the operator and further feedback it as a haptic resistance. We compare our approach to haptic feedback based on needle forces and visual feedback without haptics. Participants are asked to realize needle insertions with each of the three feedback modes. We use phantoms that mimic the structures punctured during epidural anesthesia. We show that visual feedback improves needle placement, but only proximity-based haptic feedback reduces accidental puncture. The puncture rate is 62% for force-based haptic feedback, 60% for visual feedback and 6% for proximity-based haptic feedback. Final needle placement inside the epidural space is achieved in 38%, 70% and 96% for force-based haptic, visual and proximity-based haptic feedback, respectively. Our results suggest that proximity-based haptic feedback could improve needle placement safety in the context of epidural anesthesia.
- Open Access
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3356-3364
Ultrasound Shear Wave Elasticity Imaging With Spatio-Temporal Deep Learning
Ultrasound shear wave elasticity imaging is a valuable tool for quantifying the elastic properties of tissue. Typically, the shear wave velocity is derived and mapped to an elasticity value, which neglects information such as the shape of the propagating shear wave or push sequence characteristics. We present 3D spatio-temporal CNNs for fast local elasticity estimation from ultrasound data. This approach is based on retrieving elastic properties from shear wave propagation within small local regions. A large training data set is acquired with a robot from homogeneous gelatin phantoms ranging from 17.42 kPa to 126.05 kPa with various push locations. The results show that our approach can estimate elastic properties on a pixelwise basis with a mean absolute error of 5.01(437) kPa. Furthermore, we estimate local elasticity independent of the push location and can even perform accurate estimates inside the push region. For phantoms with embedded inclusions, we report a 53.93% lower MAE (7.50 kPa) and on the background of 85.24% (1.64 kPa) compared to a conventional shear wave method. Overall, our method offers fast local estimations of elastic properties with small spatio-temporal window sizes.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3356-3364
Open AccessUltrasound Shear Wave Elasticity Imaging With Spatio-Temporal Deep Learning
Ultrasound shear wave elasticity imaging is a valuable tool for quantifying the elastic properties of tissue. Typically, the shear wave velocity is derived and mapped to an elasticity value, which neglects information such as the shape of the propagating shear wave or push sequence characteristics. We present 3D spatio-temporal CNNs for fast local elasticity estimation from ultrasound data. This approach is based on retrieving elastic properties from shear wave propagation within small local regions. A large training data set is acquired with a robot from homogeneous gelatin phantoms ranging from 17.42 kPa to 126.05 kPa with various push locations. The results show that our approach can estimate elastic properties on a pixelwise basis with a mean absolute error of 5.01(437) kPa. Furthermore, we estimate local elasticity independent of the push location and can even perform accurate estimates inside the push region. For phantoms with embedded inclusions, we report a 53.93% lower MAE (7.50 kPa) and on the background of 85.24% (1.64 kPa) compared to a conventional shear wave method. Overall, our method offers fast local estimations of elastic properties with small spatio-temporal window sizes.
- Open Access
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (10) , 3059-3067
Rupture Detection During Needle Insertion Using Complex OCT Data and CNNs
Objective: Soft tissue deformation and ruptures complicate needle placement. However, ruptures at tissue interfaces also contain information which helps physicians to navigate through different layers. This navigation task can be challenging, whenever ultrasound (US) image guidance is hard to align and externally sensed forces are superimposed by friction. Methods: We propose an experimental setup for reproducible needle insertions, applying optical coherence tomography (OCT) directly at the needle tip as well as external US and force measurements. Processing the complex OCT data is challenging as the penetration depth is limited and the data can be difficult to interpret. Using a machine learning approach, we show that ruptures can be detected in the complex OCT data without additional external guidance or measurements after training with multi-modal ground-truth from US and force. Results: We can detect ruptures with accuracies of 0.94 and 0.91 on homogeneous and inhomogeneous phantoms, respectively, and 0.71 for ex-situ tissues. Conclusion: We propose an experimental setup and deep learning based rupture detection for the complex OCT data in front of the needle tip, even in deeper tissue structures without the need for US or force sensor guiding. Significance: This study promises a suitable approach to complement a robust robotic needle placement.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (10) , 3059-3067
Open AccessRupture Detection During Needle Insertion Using Complex OCT Data and CNNs
Objective: Soft tissue deformation and ruptures complicate needle placement. However, ruptures at tissue interfaces also contain information which helps physicians to navigate through different layers. This navigation task can be challenging, whenever ultrasound (US) image guidance is hard to align and externally sensed forces are superimposed by friction. Methods: We propose an experimental setup for reproducible needle insertions, applying optical coherence tomography (OCT) directly at the needle tip as well as external US and force measurements. Processing the complex OCT data is challenging as the penetration depth is limited and the data can be difficult to interpret. Using a machine learning approach, we show that ruptures can be detected in the complex OCT data without additional external guidance or measurements after training with multi-modal ground-truth from US and force. Results: We can detect ruptures with accuracies of 0.94 and 0.91 on homogeneous and inhomogeneous phantoms, respectively, and 0.71 for ex-situ tissues. Conclusion: We propose an experimental setup and deep learning based rupture detection for the complex OCT data in front of the needle tip, even in deeper tissue structures without the need for US or force sensor guiding. Significance: This study promises a suitable approach to complement a robust robotic needle placement.
- Open Access
- 30 September 2020
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (1) , 23-27
4D deep learning for real-time volumetric optical coherence elastography
Purpose: Elasticity of soft tissue provides valuable information to physicians during treatment and diagnosis of diseases. A number of approaches have been proposed to estimate tissue stiffness from the shear wave velocity. Optical coherence elastography offers a particularly high spatial and temporal resolution. However, current approaches typically acquire data at different positions sequentially, making it slow and less practical for clinical application. Methods: We propose a new approach for elastography estimations using a fast imaging device to acquire small image volumes at rates of 831 Hz. The resulting sequence of phase image volumes is fed into a 4D convolutional neural network which handles both spatial and temporal data processing. We evaluate the approach on a set of image data acquired for gelatin phantoms of known elasticity. Results: Using the neural network, the gelatin concentration of unseen samples was predicted with a mean error of 0.65 ± 0.81 percentage points from 90 subsequent volumes of phase data only. We achieve a data acquisition and data processing time of under 12 ms and 22 ms, respectively. Conclusions: We demonstrate direct volumetric optical coherence elastography from phase image data. The approach does not rely on particular stimulation or sampling sequences and allows the estimation of elastic tissue properties of up to 40 Hz.
- 30 September 2020
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (1) , 23-27
Open Access4D deep learning for real-time volumetric optical coherence elastography
Purpose: Elasticity of soft tissue provides valuable information to physicians during treatment and diagnosis of diseases. A number of approaches have been proposed to estimate tissue stiffness from the shear wave velocity. Optical coherence elastography offers a particularly high spatial and temporal resolution. However, current approaches typically acquire data at different positions sequentially, making it slow and less practical for clinical application. Methods: We propose a new approach for elastography estimations using a fast imaging device to acquire small image volumes at rates of 831 Hz. The resulting sequence of phase image volumes is fed into a 4D convolutional neural network which handles both spatial and temporal data processing. We evaluate the approach on a set of image data acquired for gelatin phantoms of known elasticity. Results: Using the neural network, the gelatin concentration of unseen samples was predicted with a mean error of 0.65 ± 0.81 percentage points from 90 subsequent volumes of phase data only. We achieve a data acquisition and data processing time of under 12 ms and 22 ms, respectively. Conclusions: We demonstrate direct volumetric optical coherence elastography from phase image data. The approach does not rely on particular stimulation or sampling sequences and allows the estimation of elastic tissue properties of up to 40 Hz.