Micro-Computed Tomography (µCT) as a Tool for High-Resolution 3D Imaging and Analysis of Intraocular Lenses: Feasibility and Proof of the Methodology to Evaluate YAG Pits
Open Access
- 9 December 2022
- journal article
- research article
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (1) , 447-457
Abstract
Introduction Posterior capsule opacification (PCO) is the most frequent late sequelae after successful cataract surgery. Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered the gold standard and a well-accepted, safe, and effective measure in treating PCO. However, iatrogenic damage of the intraocular lens (IOL) due to inappropriate focusing is a quite common side effect. These permanent defects (YAG pits) can critically affect overall optical quality. Methods In this laboratory study, we used the micro-computed tomography (µCT) technique to obtain high-resolution 3D images of the lens and the YAG pits. Results To the best of our knowledge, this is the first description of a detailed analysis of IOLs with µCT technology. This non-destructive technique seems to be ideal for comparative studies, measuring dimensions of the damage, and visualizing shooting channels within the material. Conclusion µCT is excellently suited to examine an IOL in detail, analyze optics and haptics in three dimensions, and to describe all kinds of changes within the IOL without damaging it.Keywords
This publication has 20 references indexed in Scilit:
- German claims data analysis to assess impact of different intraocular lenses on posterior capsule opacification and related healthcare costsJournal of Public Health, 2017
- Cataract Surgical Rate and Socioeconomics: A Global StudyInvestigative Ophthalmology & Visual Science, 2016
- Study of Variation in Intraocular Pressure Spike (IOP) Following Nd- YAG Laser CapsulotomyJournal of Clinical and Diagnostic Research, 2016
- An Overview of Nd:YAG Laser Capsulotomy2014
- Visual outcome of cataract surgery; Study from the European Registry of Quality Outcomes for Cataract and Refractive SurgeryJournal of Cataract & Refractive Surgery, 2013
- Modern Cataract Surgery: Unfinished Business and Unanswered QuestionsSurvey of Ophthalmology, 2011
- Study of Possible Predictors Associated with Self-Assessed Visual Function after Cataract SurgeryOphthalmology, 2011
- [The experimental study of Nd: YAG laser injuring effects on intraocular lenses made by different materials].1998
- Schadensausmaß bei verschiedenen Intraokularlinsen durch die Neodymium:YAG-Laser Behandlung - Eine experimentelle StudieKlinische Monatsblätter für Augenheilkunde, 1997
- Cystoid Macular Edema, Retinal Detachment, and Glaucoma after Nd:YAG Laser Posterior CapsulotomyAmerican Journal of Ophthalmology, 1991