Channel Intensity and Edge-Based Estimation of Heart Rate via Smartphone Recordings
Open Access
Abstract
Smartphones, today, come equipped with a wide variety of sensors and high-speed processors that can capture, process, store, and communicate different types of data. Coupled with their ubiquity in recent years, these devices show potential as practical and portable healthcare monitors that are both cost-effective and accessible. To this end, this study focuses on examining the feasibility of smartphones in estimating the heart rate (HR), using video recordings of the users’ fingerprints. The proposed methodology involves two-stage processing that combines channel-intensity-based approaches (Channel-Intensity mode/Counter method) and a novel technique that relies on the spatial and temporal position of the recorded fingerprint edges (Edge-Detection mode). The dataset used here included 32 fingerprint video recordings taken from 6 subjects, using the rear camera of 2 smartphone models. Each video clip was first validated to determine whether it was suitable for Channel-Intensity mode or Edge-Detection mode, followed by further processing and heart rate estimation in the selected mode. The relative accuracy for recordings via the Edge-Detection mode was 93.04%, with a standard error of estimates (SEE) of 6.55 and Pearson’s correlation r > 0.91, while the Channel-Intensity mode showed a relative accuracy of 92.75%, with an SEE of 5.95 and a Pearson’s correlation r > 0.95. Further statistical analysis was also carried out using Pearson’s correlation test and the Bland–Altman method to verify the statistical significance of the results. The results thus show that the proposed methodology, through smartphones, is a potential alternative to existing technologies for monitoring a person’s heart rate.Keywords
This publication has 39 references indexed in Scilit:
- Prevalence, treatments and outcomes of coronary artery disease in Indians: A systematic reviewIndian Heart Journal, 2015
- Edge detection methods2015
- Extraction of Heart Rate Variability from Smartphone PhotoplethysmogramsComputational and Mathematical Methods in Medicine, 2015
- Toward Flexible and Wearable Human‐Interactive Health‐Monitoring DevicesAdvanced Healthcare Materials, 2014
- How accurate is pulse rate variability as an estimate of heart rate variability?International Journal of Cardiology, 2013
- Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth ApplicationsInternational Journal of Telemedicine and Applications, 2012
- Cellular phone‐based photoplethysmographic imagingJournal of Biophotonics, 2010
- I. Using the Bland–Altman method to measure agreement with repeated measuresBritish Journal of Anaesthesia, 2007
- Validity of Seven Commercially Available Heart Rate MonitorsMeasurement in Physical Education and Exercise Science, 2002
- An advanced detrending method with application to HRV analysisIEEE Transactions on Biomedical Engineering, 2002